Automatic Remote Monitoring of Implantable Cardioverter-Defibrillator Lead and Generator Performance The Lumos-T Safely RedUceS RouTine Office Device Follow-Up (TRUST) Trial

被引:126
|
作者
Varma, Niraj [1 ]
Michalski, Justin
Epstein, Andrew E. [2 ]
Schweikert, Robert [3 ]
机构
[1] Cleveland Clin, Dept Cardiovasc Med, Cleveland, OH 44195 USA
[2] Univ Penn, Philadelphia, PA 19104 USA
[3] Akron Gen Med Ctr, Akron, OH USA
关键词
defibrillators; monitoring; follow-up; remote monitoring; SOCIETY TASK-FORCE; FAILURE; RECOMMENDATIONS; RATIONALE; PACEMAKER; EFFICACY; POLICIES; DESIGN;
D O I
10.1161/CIRCEP.110.951962
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Monitoring performance of implantable cardioverter-defibrillator (ICD) generators and leads is important. Methods available are with in-person evaluations or by automatic remote home monitoring (HM). These were prospectively evaluated and compared in the TRUST trial. The HM technology tested performed daily self-checks and databasing with rapid event notifications for out-of-range (including asymptomatic) conditions. Methods and Results-Patients (n = 1339) were randomly assigned after ICD implant 2:1 to HM or to conventional groups. Both groups underwent scheduled checks every 3 months and were followed for 15 months. In HM, in-person office visits were scheduled at 3 and 15 months. At 6, 9, and 12 months, HM only was used with subsequent office visits if necessary. Between these time points, ICDs triggered event notifications for system integrity problems. Patients randomly assigned to conventional follow-up were evaluated with office visits only. HM and conventional patients were similar (age, 63.3 +/- 12.8 versus 64.0 +/- 12.1 years; 72.0% versus 73.1% male; New York Heart Association II class, 55.9% versus 60.4%; left ventricular ejection fraction, 29.0 +/- 10.7% versus 28.5 +/- 9.8%; coronary artery disease, 64.8% versus 71.7%; primary prevention, 72.2% versus 73.8%; DDD devices, 57.8% versus 56.6%). Four patients crossed over from conventional to HM because of advisories. Scheduled checks were more successfully accomplished in HM (92.7% versus 89.2% in conventional, P < 0.001). Sixty-two device-related events (53 in HM versus 9 in conventional) were observed in 46 patients (40 [4.4%] in HM versus 6 [1.39%] in conventional, P = 0.004). Forty-seven percent were asymptomatic. HM detected generator and lead problems earlier (HM versus conventional: median, 1 versus 5 days; P = 0.05). A total of 20 device problems (eg, lead fracture, elective replacement indicators) requiring surgical revision (0.012 per patient-year) were found, 15 in HM and 5 in the conventional groups. Other events were managed nonsurgically (eg, reprogramming, initiation of antiarrhythmics). Conclusions-ICD lead and generator malfunction was infrequent and often asymptomatic. Only a minority of detected events required surgical intervention. Automatic HM enhanced discovery, permitted prompt detection, and facilitated management decisions. Longitudinal parameter trending, with component function evaluated daily by remote monitoring, may enable long-term performance assessment.
引用
收藏
页码:428 / 436
页数:9
相关论文
共 4 条
  • [1] Efficacy and Safety of Automatic Remote Monitoring for Implantable Cardioverter-Defibrillator Follow-Up The Lumos-T Safely Reduces Routine Office Device Follow-Up (TRUST) Trial
    Varma, Niraj
    Epstein, Andrew E.
    Irimpen, Anand
    Schweikert, Robert
    Love, Charles
    CIRCULATION, 2010, 122 (04) : 325 - U28
  • [2] Role of Automatic Wireless Remote Monitoring Immediately Following ICD Implant: The Lumos-T Reduces Routine Office Device Follow-Up Study (TRUST) Trial
    Varma, Niraj
    Epstein, Andrew E.
    Schweikert, Robert
    Michalski, Justin
    Love, Charles J.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (03) : 321 - 326
  • [3] Contributions of remote monitoring to the follow-up of implantable cardioverter-defibrillator leads under advisory
    Guedon-Moreau, Laurence
    Chevalier, Philippe
    Marquie, Christelle
    Kouakam, Claude
    Klug, Didier
    Lacroix, Dominique
    Brigadeau, Francois
    Kacet, Salem
    EUROPEAN HEART JOURNAL, 2010, 31 (18) : 2246 - 2252
  • [4] The impact of remote monitoring of implanted cardioverter-defibrillator (ICD) and cardiac resynchronisation therapy device (CRT-D) patients on healthcare costs in the Silesian population: three-year follow-up
    Buchta, Piotr
    Tajstra, Mateusz
    Kurek, Anna
    Skrzypek, Michal
    Swietlinska, Malgorzata
    Gadula-Gacek, Elzbieta
    Wasiak, Michal
    Pyka, Lukasz
    Gasior, Mariusz
    KARDIOLOGIA POLSKA, 2017, 75 (06) : 573 - 579