Ultrasensitive detection of ochratoxin A using aptasensors

被引:117
作者
Bostan, Hasan Badie [1 ]
Danesh, Noor Mohammad [2 ,3 ,4 ]
Karimi, Gholamreza [1 ]
Ramezani, Mohammad [2 ]
Shaegh, Seyed Ali Mousavi [5 ]
Youssefi, Kazem [6 ]
Charbgoo, Fahimeh [1 ]
Abnous, Khalil [1 ,7 ]
Taghdisi, Seyed Mohammad [8 ,9 ]
机构
[1] Mashhad Univ Med Sci, Pharmaceut Res Ctr, Mashhad, Iran
[2] Mashhad Univ Med Sci, Nanotechnol Res Ctr, Mashhad, Iran
[3] Res Inst Sci & New Technol, Mashhad, Iran
[4] Mashhad Univ Med Sci, Student Res Comm, Mashhad, Iran
[5] Mashhad Univ Med Sci, Orthoped Res Ctr, Mashhad 9176699199, Iran
[6] Tabaran Inst Higher Educ, Dept English, Mashhad, Iran
[7] Mashhad Univ Med Sci, Sch Pharm, Dept Med Chem, Mashhad, Iran
[8] Mashhad Univ Med Sci, Targeted Drug Delivery Res Ctr, Mashhad, Iran
[9] Mashhad Univ Med Sci, Sch Pharm, Dept Pharmaceut Biotechnol, Mashhad, Iran
关键词
Ochratoxin A; Aptasensor; Detection; Optical; Fluorescence; Electrochemical; SURFACE-PLASMON RESONANCE; HIGHLY SENSITIVE DETECTION; FLUORESCENT APTASENSOR; LABEL-FREE; GOLD NANOPARTICLES; IMPEDIMETRIC APTASENSOR; RAPID DETECTION; ENERGY-TRANSFER; ELECTROCHEMICAL APTASENSOR; QUANTITATIVE DETECTION;
D O I
10.1016/j.bios.2017.06.055
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Regarding teratogenic, carcinogenic, and immunotoxic nature of ochratoxin A (OTA), selective and sensitive monitoring of this molecule in food samples is of great importance. In recent years, various methods have been introduced for detection of OTA. However, they are usually time-consuming, labor-intensive and expensive. Therefore, these parameters limited their usage. The emerging method of detection, aptasensor, has attracted more attention for OTA detection, due to distinctive advantages including high sensitivity, selectivity and simplicity. In this review, the new developed aptasensors for detection of OTA have been investigated. We also highlighted advantages and disadvantages of different types of OTA aptasensors. This review also takes into consideration the goal to find out which designs are the most rational ones for highly sensitive detection of OTA.
引用
收藏
页码:168 / 179
页数:12
相关论文
共 79 条
[1]   Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement [J].
Anfossi, L. ;
Di Nardo, F. ;
Giovannoli, C. ;
Passini, C. ;
Baggiani, C. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (30) :9859-9867
[2]   Electrochemical DNA aptamer-based biosensor for OTA detection, using superparamagnetic nanoparticles [J].
Barthelmebs, Lise ;
Hayat, Akhtar ;
Limiadi, Ambrosius Wis ;
Marty, Jean-Louis ;
Noguer, Thierry .
SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02) :932-937
[3]   Rapid Visual Tests: Fast and Reliable Detection of Ochratoxin A [J].
Bazin, Ingrid ;
Nabais, Elodie ;
Lopez-Ferber, Miguel .
TOXINS, 2010, 2 (09) :2230-2241
[4]   Aptamers as tools for target validation [J].
Blank, M ;
Blind, M .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2005, 9 (04) :336-342
[5]   An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer [J].
Bonel, Laura ;
Vidal, Juan C. ;
Duato, Patricia ;
Castillo, Juan R. .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (07) :3254-3259
[6]   Sensitive analytical performance of folding based biosensor using methylene blue tagged aptamers [J].
Catanante, Gaelle ;
Mishra, Rupesh K. ;
Hayat, Akhtar ;
Marty, Jean-Louis .
TALANTA, 2016, 153 :138-144
[7]   Nanoparticles application in high sensitive aptasensor design [J].
Charbgoo, Fahimeh ;
Soltani, Fatemeh ;
Taghdisi, Seyed Mohammad ;
Abnous, Khalil ;
Ramezani, Mohammad .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2016, 85 :85-97
[8]   Recent advances in mycotoxins detection [J].
Chauhan, Ruchika ;
Singh, Jay ;
Sachdev, Tushar ;
Basu, T. ;
Malhotra, B. D. .
BIOSENSORS & BIOELECTRONICS, 2016, 81 :532-545
[9]   A fluorescent aptasensor based on DNA-scaffolded silver-nanocluster for ochratoxin A detection [J].
Chen, Jinghua ;
Zhang, Xi ;
Cai, Shuxian ;
Wu, Dongzhi ;
Chen, Mei ;
Wang, Shihua ;
Zhang, Jing .
BIOSENSORS & BIOELECTRONICS, 2014, 57 :226-231
[10]   An aptasensor for ochratoxin A based on grafting of polyethylene glycol on a boron-doped diamond microcell [J].
Chrouda, A. ;
Sbartai, A. ;
Baraket, A. ;
Renaud, L. ;
Maaref, A. ;
Jaffrezic-Renault, N. .
ANALYTICAL BIOCHEMISTRY, 2015, 488 :36-44