Rapid atrial pacing does not decrease the atrial defibrillation threshold

被引:1
作者
Frykman, V [1 ]
Darpö, B
Ayers, GM
Bergfeldt, L
Linde, C
Rosenqvist, M
机构
[1] Karolinska Hosp, Dept Cardiol, S-17176 Stockholm, Sweden
[2] MPM Capital LP, San Francisco, CA USA
[3] Soder Sjukhuset, Dept Cardiol, Stockholm, Sweden
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 2003年 / 26卷 / 07期
关键词
atrial fibrillation; internal defibrillation; cardioversion; defibrillation threshold;
D O I
10.1046/j.1460-9592.2003.t01-1-00211.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of the study was to evaluate the effect of preshock atrial pacing on the atrial defibrillation threshold (DFT) during internal cardioversion of AF. The implantable atrial defibrillator has been added to the therapeutic options for patients with recurrent episodes of persistent AE Although the device is efficient in restoring sinus rhythm, patient discomfort is a limitation. Methods that lower the ADFT are needed. Eleven patients with AF underwent internal cardioversion. In a randomized, crossover design, ADFT testing was performed, applying a step-up protocol starting at 100 V Rapid atrial pacing was performed with a right atrial catheter for 20 seconds at 90% of the average cycle length of the fibrillatory waves and was immediately followed by a biphasic defibrillation shock. At each energy level, pacing + shock was compared to shock only, until the level at which sinus rhythm was restored by both modes. The step-up protocol was thereafter repeated using the inverse sequence of the two modes. A total of 19 ADFTs were obtained. For 10 the ADFT was lower with pacing + shock, in 4 equal and in 5 higher, than with shock only. The ADFT (mean +/- SD) with pacing + shock was 260 +/- 84 V (3.4 +/- 2.9 J) and did not differ from shock only: 268 +/- 85 V (3.8 +/- 3.0 J) (P > 0.05). The coefficient of variation and the coefficient of reproducibility for pacing + shock was 16% and 60 V, respectively, and for shock only 17% and 61 V Rapid atrial pacing did not influence the internal ADFT in AE The randomized, crossover protocol used was reproducible between different modes, and seems useful when testing the impact of different interventions on the ADFT.
引用
收藏
页码:1461 / 1466
页数:6
相关论文
共 50 条
  • [31] Aliskiren protecting atrial structural remodeling from rapid atrial pacing in a canine model
    Zhiqiang Zhao
    Yan Chen
    Weimin Li
    Xinghua Wang
    Jian Li
    Wansong Yang
    Lijun Cheng
    Tong Liu
    Enzhao Liu
    Guangping Li
    Naunyn-Schmiedeberg's Archives of Pharmacology, 2016, 389 : 863 - 871
  • [32] Effect of renal sympathetic denervation on the inducibility of atrial fibrillation during rapid atrial pacing
    Qingyan Zhao
    Shengbo Yu
    Minghui Zou
    Zixuan Dai
    Xule Wang
    Jinping Xiao
    Congxin Huang
    Journal of Interventional Cardiac Electrophysiology, 2012, 35 : 119 - 125
  • [33] Effect of c-Ski on atrial remodelling in a rapid atrial pacing canine model
    Wang, Juan
    Han, Min
    Han, Su-xia
    Zhi, Cuiju
    Gao, Suli
    Li, Yao
    JOURNAL OF CELLULAR AND MOLECULAR MEDICINE, 2020, 24 (02) : 1795 - 1803
  • [34] Atrial reverse remodeling: Restitution of early tachycardia-induced alterations of atrial ion currents after termination of rapid atrial pacing in rabbits
    Laszlo, Roman
    Konior, Agnes
    Bentz, Kerstin
    Eick, Christian
    Schreiner, Birgit
    Schreieck, Juergen
    Bosch, Ralph F.
    RESEARCH IN VETERINARY SCIENCE, 2013, 94 (02) : 320 - 324
  • [35] Protective Effects of Aliskiren on Atrial Ionic Remodeling in a Canine Model of Rapid Atrial Pacing
    Zhao, Zhiqiang
    Wang, Xinghua
    Li, Jian
    Yang, Wansong
    Cheng, Lijun
    Chen, Yan
    Liu, Tong
    Liu, Enzhao
    Chen, Kangyin
    Li, Guangping
    CARDIOVASCULAR DRUGS AND THERAPY, 2014, 28 (02) : 137 - 143
  • [36] Aliskiren protecting atrial structural remodeling from rapid atrial pacing in a canine model
    Zhao, Zhiqiang
    Chen, Yan
    Li, Weimin
    Wang, Xinghua
    Li, Jian
    Yang, Wansong
    Cheng, Lijun
    Liu, Tong
    Liu, Enzhao
    Li, Guangping
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2016, 389 (08) : 863 - 871
  • [37] The impact of rapid atrial pacing on ADMA and endothelial NOS
    Goette, Andreas
    Hammwoehner, Matthias
    Bukowska, Alicja
    Scalera, Fortunato
    Martens-Lobenhoffer, Jens
    Dobrev, Dobromir
    Ravens, Ursula
    Weinert, Soenke
    Medunjanin, Senad
    Lendeckel, Uwe
    Bode-Boeger, Stefanie M.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2012, 154 (02) : 141 - 146
  • [38] Rapid pacing results in changes in atrial but not in ventricular refractoriness
    Schoonderwoerd, BA
    Van Gelder, IC
    Tieleman, RG
    Bel, KJ
    Crijns, HJGM
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (03): : 287 - 290
  • [39] Reduction of the internal atrial defibrillation threshold with balanced orthogonal sequential shocks
    Zheng, XS
    Benser, ME
    Walcott, GP
    Smith, WM
    Ideker, RE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2002, 13 (09) : 904 - 909
  • [40] Coronary sinus electrode does not reduce atrial defibrillation thresholds
    Rashba, EJ
    Shorofsky, SR
    Scheiner, A
    Peters, RW
    Ma, C
    Gold, MR
    HEART RHYTHM, 2006, 3 (06) : 647 - 652