Examination of EMG normalisation methods for the study of the posterior and posterolateral neck muscles in healthy controls

被引:39
作者
Burnett, Angus [1 ]
Green, Jonathon
Netto, Kevin
Rodrigues, Julian
机构
[1] Curtin Univ Technol, Sch Physiotherapy, GPO U1987, Bentley, WA 6102, Australia
[2] Edith Cowan Univ, Sch Exercise Biomed & Hlth Sci, Churchlands, WA 6018, Australia
[3] Univ Western Australia, Ctr Neuromuscular & Neurol Disorders, Nedlands, WA 6009, Australia
关键词
electromyography; normalisation intramuscular; reliability; neck;
D O I
10.1016/j.jelekin.2006.06.003
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The purpose of this study was to examine the reliability of normalisation methods used in the study of the posterior and posterolateral neck muscles in a group of healthy controls. Six asymptomatic male subjects performed a total of 12 maximum voluntary isometric contractions (MVIC) and 60%-submaximal isometric contractions (60%-MVIC) against the torque arm of an isokinetic dynamometer whilst surface and intramuscular electromyography (EMG) was recorded unilaterally from representative posterior and posterolateral locations. Reliability was calculated using intra-class correlation coefficient (ICC), relative standard error of measurement (%SEM) and relative coefficient of variation (%CV). Maximal torque output was found to be highly reliable in the directions of extension and right lateral bending when the first of three MVIC contractions was excluded. When averaged across contraction direction, high reliability was found for both surface (MVIC: ICC = 0.986, %SEM = 7.5, %CV = 9.2; 60%-MVIC: ICC = 0.975, %SEM = 10, %CV = 13.7) and intramuscular (MVIC: ICC = 0.910, %SEM = 20, %CV = 19.1; 60%-MVIC: ICC = 0.952, %SEM = 16.5, %CV = 13.5) electrodes. Intramuscular electrodes displayed the least reliability in right lateral bending. The use of visual feedback markedly increased the reliability of 60%-MVIC contractions. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:635 / 641
页数:7
相关论文
共 28 条
[1]   EMG signal amplitude assessment during abdominal bracing and hollowing [J].
Allison, GT ;
Godfrey, P ;
Robinson, G .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1998, 8 (01) :51-57
[2]   Evaluation of cervical range of motion and isometric neck muscle strength: reliability and validity [J].
Chiu, TTW ;
Lo, SK .
CLINICAL REHABILITATION, 2002, 16 (08) :851-858
[3]   Comparison of biomechanical human neck models: Muscle forces and spinal loads at C4/5 level [J].
Choi, H ;
Vanderby, R .
JOURNAL OF APPLIED BIOMECHANICS, 1999, 15 (02) :120-138
[4]   Reliability of EMG measurements for trunk muscles during maximal and sub-maximal voluntary isometric contractions in healthy controls and CLBP patients [J].
Dankaerts, W ;
O'Sullivan, PB ;
Burnett, AF ;
Straker, LM ;
Danneels, LA .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2004, 14 (03) :333-342
[5]   Repeatability of surface EMG variables in the sternocleidomastoid and anterior scalene muscles [J].
Falla, D ;
Dall'Alba, P ;
Rainoldi, A ;
Merletti, R ;
Jull, G .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2002, 87 (06) :542-549
[6]  
Freriks B., 1999, RECOMMENDATIONS SENS, P19
[7]  
Green NDC, 2004, AVIAT SPACE ENVIR MD, V75, P676
[8]   Estimating maximal EMG amplitude for the trapezius muscle: On the optimization of experimental procedure and electrode placement for improved reliability and increased signal amplitude [J].
Jensen, C ;
Vasseljen, O ;
Westgaard, RH .
JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 1996, 6 (01) :51-58
[9]   Reliability of computed tomography measurements of paraspinal muscle cross-sectional area and density in patients with chronic low back pain [J].
Keller, A ;
Gunderson, R ;
Reikerås, O ;
Brox, JI .
SPINE, 2003, 28 (13) :1455-1460
[10]  
KESHNER EA, 1989, EXP BRAIN RES, V75, P335