Two-dimensional tools for analyzing polymer microstructure; coupling non-aqueous ion-exchange chromatography to size-exclusion chromatography

被引:3
作者
Brooijmans, Ton [1 ,2 ,3 ]
Gonzalez, Pascal Camoiras [2 ]
Pirok, Bob [2 ]
Schoenmakers, Peter [2 ]
Peters, Ron [1 ,2 ]
机构
[1] Covestro, Testing Analyt & Phys Dept, Waalwijk, Netherlands
[2] Univ Amsterdam, Vant Hoff Inst Mol Sci HIMS, Amsterdam, Netherlands
[3] Sluisweg 12, Waalwijk, Netherlands
关键词
On -aqueous ion -exchange chromatography; Water -borne polymers; Heterogeneity analysis; Two-dimensional liquid chromatography; LIQUID-CHROMATOGRAPHY; SEPARATIONS; ACRYLATE;
D O I
10.1016/j.chroma.2022.463536
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Traditional liquid-chromatographic techniques, such as size-exclusion chromatography, (critical) interac-tion chromatography, and hydrodynamic chromatography, can all reveal certain aspects of polymers and the underlying distributions. The distribution of incorporated acid groups present in polyacrylates can be determined by non-aqueous ion-exchange chromatography, independent of other distributions present. The microstructural details on how this number of acid groups is incorporated in the polymer remains unknown. A low-molar mass polymer molecule with high acid content and a high-molar mass polymer with a low acid content may have the exact same number of acid groups. To take a next step towards understanding the polymer microstructure of water-borne resins, the distribution of incorporated acid groups over the molar-mass distribution has been investigated.For this purpose, an on-line coupling of non-aqueous ion-exchange chromatography (NAIEX) to size -exclusion chromatography (SEC) was established. Practical considerations regarding the system setup with respect to chromatography modes and column-and valve switching dimensionality are discussed. The orthogonality of NAIEX and SEC is demonstrated. Both liquid chromatography modes may be calibrated using polymer standards, yielding a calibrated separation plane. Cross-sectional data on either the molar mass distribution or the acid group distribution at a certain point of the separation plane is obtained. The value of the designed setup was demonstrated by the detailed characterization of the combined acid -group and molar-mass distribution in polymers with a low acid content, in the order of a few mass-%. Several stages of the emulsion polymerization process could be identified using the combined power of NAIEX and SEC.(c) 2022 Elsevier B.V. All rights reserved.
引用
收藏
页数:9
相关论文
共 33 条
[1]   Triethylammonium acetate ionic liquid assisted one-pot synthesis of dihydropyrimidinones and evaluation of their antioxidant and antibacterial activities [J].
Attri, Pankaj ;
Bhatia, Rohit ;
Gaur, Jitender ;
Arora, Bharti ;
Gupta, Anjali ;
Kumar, Naresh ;
Choi, Eun Ha .
ARABIAN JOURNAL OF CHEMISTRY, 2017, 10 (02) :206-214
[2]  
Batchelor D., 2000, Chromophobia
[3]   Two-dimensional liquid chromatography of synthetic polymers [J].
Berek, Dusan .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2010, 396 (01) :421-441
[4]   Reducing the influence of geometry-induced gradient deformation in liquid chromatographic retention modelling [J].
Bos, Tijmen S. ;
Niezen, Leon E. ;
den Uijl, Mimi J. ;
Molenaar, Stef R. A. ;
Lege, Sascha ;
Schoenmakers, Peter J. ;
Somsen, Govert W. ;
Pirok, Bob W. J. .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1635
[5]   Heterogeneity analysis of polymeric carboxylic acid functionality by selective derivatization followed by size exclusion chromatography [J].
Brooijmans, T. ;
Okhuijsen, R. A. ;
Oerlemans, G. M. M. ;
Pirok, B. W. J. ;
Schoenmakers, P. J. ;
Peters, R. A. H. .
ANALYTICA CHIMICA ACTA, 2019, 1072 :87-94
[6]   Charge-based separation of synthetic macromolecules by non-aqueous ion exchange chromatography [J].
Brooijmans, Ton ;
Breuer, Pascal ;
Schoenmakers, Peter J. ;
Peters, Ron A. H. .
JOURNAL OF CHROMATOGRAPHY A, 2020, 1626
[7]   AUTOMATED INSTRUMENTATION FOR COMPREHENSIVE 2-DIMENSIONAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF PROTEINS [J].
BUSHEY, MM ;
JORGENSON, JW .
ANALYTICAL CHEMISTRY, 1990, 62 (02) :161-167
[8]  
Carr P.W., 2015, 2 DIMENSIONAL LIQUID
[9]   2-DIMENSIONAL COLUMN LIQUID-CHROMATOGRAPHIC TECHNIQUE FOR RESOLUTION OF COMPLEX-MIXTURES [J].
ERNI, F ;
FREI, RW .
JOURNAL OF CHROMATOGRAPHY, 1978, 149 (FEB) :561-569
[10]   Comprehensive liquid chromatography: Fundamental aspects and practical considerations-A review [J].
Francois, Isabelle ;
Sandra, Koen ;
Sandra, Pat .
ANALYTICA CHIMICA ACTA, 2009, 641 (1-2) :14-31