Low Prevalence of Inappropriate Shocks in Patients With Inherited Arrhythmia Syndromes With the Subcutaneous Implantable Defibrillator Single Center Experience and Long-Term Follow-Up

被引:26
作者
Rudic, Boris
Tueluemen, Erol
Berlin, Veronika
Roeger, Susanne
Stach, Ksenija
Liebe, Volker
El-Battrawy, Ibrahim
Doesch, Christina
Papavassiliu, Theano
Akin, Ibrahim
Borggrefe, Martin
Kuschyk, Juergen
机构
[1] Univ Med Ctr Mannheim, Dept Med, Mannheim, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Heidelberg Mannheim, Mannheim, Germany
来源
JOURNAL OF THE AMERICAN HEART ASSOCIATION | 2017年 / 6卷 / 10期
关键词
Brugada syndrome; hypertrophic cardiomyopathy; implantable cardioverter-defibrillator; sudden cardiac death; ventricular tachycardia arrhythmia; CARDIOVERTER-DEFIBRILLATOR; BRUGADA-SYNDROME; EFFICACY; PREVENTION; PREDICTORS; REGISTRY; SAFETY;
D O I
10.1161/JAHA.117.006265
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-Up to 40% of patients with transvenous implantable cardioverter-defibrillator (ICD) experience lead-associated complications and may suffer from high complication rates when lead extraction is indicated. Subcutaneous ICD may represent a feasible alternative; however, the efficacy of the subcutaneous ICD in the detection and treatment of ventricular arrhythmias in patients with hereditary arrhythmia syndromes has not been fully evaluated. Methods and Results-Patients with primary hereditary arrhythmia syndromes who fulfilled indication for defibrillator placement were eligible for enrollment. Between 2010 and 2016, 62 consecutive patients with primary hereditary arrhythmia syndromes, without indication for antibradycardia therapy, were enrolled in the study. Mean follow-up was 31.0 +/- 14.2 months. The study cohort comprised of 24 patients with Brugada syndrome, 17 with idiopathic ventricular fibrillation, 6 with long-QT syndrome, 1 with short-QT syndrome, 3 with catecholaminergic polymorphic ventricular tachycardia, 8 with hypertrophic cardiomyopathy, and 3 with arrhythmogenic right ventricular cardiomyopathy. Thirty-nine patients were implanted for secondary prevention. Twenty-two patients had a previous transvenous ICD implanted, but required revision because of infection or lead defects. A total of 20 spontaneous ventricular tachyarrhythmias requiring shock intervention occurred in 10 patients during follow-up. All episodes were terminated within the first ICD shock delivery with 80 J. Two patients had inappropriate therapies caused by oversensing following an uneventful implantation. No pocket-site infections and no premature revisions have occurred during follow-up. Conclusions-Our study supports the use of the subcutaneous ICD for both secondary and primary prevention of sudden cardiac death as a reliable alternative to the conventional transvenous ICD.
引用
收藏
页数:9
相关论文
共 20 条
[1]   Complications of implantable cardioverter defibrillator therapy in 440 consecutive patients [J].
Alter, P ;
Waldhans, S ;
Plachta, E ;
Moosdorf, R ;
Grimm, W .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (09) :926-932
[2]   Shock Efficacy of Subcutaneous Implantable Cardioverter-Defibrillator for Prevention of Sudden Cardiac Death Initial Multicenter Experience [J].
Aydin, Ali ;
Hartel, Friederike ;
Schlueter, Michael ;
Butter, Christian ;
Koebe, Julia ;
Seifert, Martin ;
Gosau, Nils ;
Hoffmann, Boris ;
Hoffmann, Matthias ;
Vettorazzi, Eik ;
Wilke, Iris ;
Wegscheider, Karl ;
Reichenspurner, Hermann ;
Eckardt, Lars ;
Steven, Daniel ;
Willems, Stephan .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2012, 5 (05) :913-919
[3]   Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure [J].
Bardy, GH ;
Lee, KL ;
Mark, DB ;
Poole, JE ;
Packer, DL ;
Boineau, R ;
Domanski, M ;
Troutman, C ;
Anderson, J ;
Johnson, G ;
McNulty, SE ;
Clapp-Channing, N ;
Davidson-Ray, LD ;
Fraulo, ES ;
Fishbein, DP ;
Luceri, RM ;
Ip, JH .
NEW ENGLAND JOURNAL OF MEDICINE, 2005, 352 (03) :225-237
[4]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[5]   Clinical predictors and prognostic significance of electrical storm in patients with implantable cardioverter defibrillators [J].
Brigadeau, F ;
Kouakam, C ;
Klug, D ;
Marquié, C ;
Duhamel, A ;
Mizon-Gérard, F ;
Lacroix, D ;
Kacet, S .
EUROPEAN HEART JOURNAL, 2006, 27 (06) :700-707
[6]   Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry [J].
Burke, Martin C. ;
Gold, Michael R. ;
Knight, Bradley P. ;
Barr, Craig S. ;
Theuns, Dominic A. M. J. ;
Boersma, Lucas V. A. ;
Knops, Reinoud E. ;
Weiss, Raul ;
Leon, Angel R. ;
Herre, John M. ;
Husby, Michael ;
Stein, Kenneth M. ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) :1605-1615
[7]   Use of a discrimination algorithm to reduce inappropriate shocks with a subcutaneous implantable cardioverter-defibrillator [J].
Gold, Michael R. ;
Weiss, Raul ;
Theuns, Dominic A. M. J. ;
Smith, Warren ;
Leon, Angel ;
Knight, Bradley P. ;
Carter, Nathan ;
Husby, Michael ;
Burke, Martin C. .
HEART RHYTHM, 2014, 11 (08) :1352-1358
[8]   Use of an electrocardiographic screening tool to determine candidacy for a subcutaneous implantable cardioverter-defibrillator [J].
Groh, Christopher A. ;
Sharma, Shishir ;
Pelchovitz, Daniel J. ;
Bhave, Prashant D. ;
Rhyner, John ;
Verma, Nishant ;
Arora, Rishi ;
Chicos, Alexandru B. ;
Kim, Susan S. ;
Lin, Albert C. ;
Passman, Rod S. ;
Knight, Bradley P. .
HEART RHYTHM, 2014, 11 (08) :1361-1366
[9]   Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of > 10 years [J].
Kleemann, Thomas ;
Becker, Torsten ;
Doenges, Klaus ;
Vater, Margit ;
Senges, Jochen ;
Schneider, Steffen ;
Saggau, Werner ;
Weisse, Udo ;
Seidl, Karlheinz .
CIRCULATION, 2007, 115 (19) :2474-2480
[10]   Worldwide experience with a totally subcutaneous implantable defibrillator: early results from the EFFORTLESS S-ICD Registry [J].
Lambiase, Pier D. ;
Barr, Craig ;
Theuns, Dominic A. M. J. ;
Knops, Reinoud ;
Neuzil, Petr ;
Johansen, Jens Brock ;
Hood, Margaret ;
Pedersen, Susanne ;
Kaeaeb, Stefan ;
Murgatroyd, Francis ;
Reeve, Helen L. ;
Carter, Nathan ;
Boersma, Lucas .
EUROPEAN HEART JOURNAL, 2014, 35 (25) :1657-+