Direct Comparison of Diagnostic Performance of 9 Quantitative Fecal Immunochemical Tests for Colorectal Cancer Screening

被引:93
|
作者
Gies, Anton [1 ,2 ]
Cuk, Katarina [3 ]
Schrotz-King, Petra [1 ,2 ]
Brenner, Hermann [1 ,2 ,3 ,4 ]
机构
[1] German Canc Res Ctr, Div Prevent Oncol, Heidelberg, Germany
[2] Natl Ctr Tumor Dis NCT, Heidelberg, Germany
[3] German Canc Res Ctr, Div Clin Epidemiol & Aging Res, Neuenheimer Feld 581, D-69120 Heidelberg, Germany
[4] German Canc Res Ctr, German Canc Consortium DKTK, Heidelberg, Germany
关键词
Fecal Occult Blood Test; Colon Cancer; Advanced Adenoma; Early Detection; OCCULT BLOOD-TEST; HEMOGLOBIN; NEOPLASIA; COLONOSCOPY; ADENOMAS;
D O I
10.1053/j.gastro.2017.09.018
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
BACKGROUND & AIMS: A variety of fecal immunochemical tests (FITs) for hemoglobin (Hb) are used in colorectal cancer screening. It is unclear to what extent differences in reported sensitivities and specificities reflect true heterogeneity in test performance or differences in study populations or varying pre-analytical conditions. We directly compared the sensitivity and specificity values with which 9 quantitative (laboratory-based and point-of-care) FITs detected advanced neoplasms (AN) in a single colorectal cancer screening study. METHODS: Pre-colonoscopy stool samples were obtained from participants of screening colonoscopy in Germany from 2005 through 2010 and frozen at -80 degrees C until analysis. The stool samples were thawed, homogenized, and used for 9 different quantitative FITs in parallel. Colonoscopy and histology reports were collected from all participants and evaluated by 2 independent, trained research assistants who were blinded to the test results. Comparative evaluations of diagnostic performance for AN were made at preset manufacturers' thresholds (range, 2.0-17.0 mu g Hb/g feces), at a uniform threshold (15 mu g Hb/g feces), and at adjusted thresholds yielding defined levels of specificity (99%, 97%, and 93%). RESULTS: Of the 1667 participants who fulfilled the inclusion criteria, all cases with AN (n = 216) and 300 randomly selected individuals without AN were included in the analysis. Sensitivities and specificities for AN varied widely when we used the preset thresholds (21.8%-46.3% and 85.7%-97.7%, respectively) or the uniform threshold (16.2%-34.3% and 94.0%-98.0%, respectively). Adjusting thresholds to yield a specificity of 99%, 97%, or 93% resulted in almost equal sensitivities for detection of AN 14.4%-18.5%, 21.3%-23.6%, and 30.1%-35.2%, respectively) and almost equal positivity rates (2.8%-3.4%, 5.8%-6.1%, and 10.1%-10.9%, respectively). CONCLUSIONS: Apparent heterogeneity in diagnostic performance of quantitative FITs can be overcome to a large extent by adjusting thresholds to yield defined levels of specificity or positivity rates. Rather than simply using thresholds recommended by the manufacturer, screening programs should choose thresholds based on intended levels of specificity and manageable positivity rates.
引用
收藏
页码:93 / 104
页数:12
相关论文
共 50 条
  • [1] Quantitative fecal immunochemical tests for colorectal cancer screening
    Gies, Anton
    Bhardwaj, Megha
    Stock, Christian
    Schrotz-King, Petra
    Brenner, Hermann
    INTERNATIONAL JOURNAL OF CANCER, 2018, 143 (02) : 234 - 244
  • [2] Combination of Different Fecal Immunochemical Tests in Colorectal Cancer Screening: Any Gain in Diagnostic Performance?
    Gies, Anton
    Cuk, Katarina
    Schrotz-King, Petra
    Brenner, Hermann
    CANCERS, 2019, 11 (01)
  • [3] Fecal immunochemical test for hemoglobin in combination with fecal transferrin in colorectal cancer screening
    Gies, Anton
    Cuk, Katarina
    Schrotz-King, Petra
    Brenner, Hermann
    UNITED EUROPEAN GASTROENTEROLOGY JOURNAL, 2018, 6 (08) : 1223 - 1231
  • [4] Effects of Oral Anticoagulants and Aspirin on Performance of Fecal Immunochemical Tests in Colorectal Cancer Screening
    Randel, Kristin Ranheim
    Botteri, Edoardo
    Romsta, Katrine Maria Kauczynska
    Frigstad, Svein Oskar
    Bretthauer, Michael
    Hoff, Geir
    de Lange, Thomas
    Holme, Oyvind
    GASTROENTEROLOGY, 2019, 156 (06) : 1642 - +
  • [5] Fecal Immunochemical Tests for Colorectal Cancer Screening
    Daly, Jeanette
    AMERICAN JOURNAL OF NURSING, 2012, 112 (10) : 67 - 69
  • [6] Effect of Imperfect Compliance With Instructions for Fecal Sample Collection on Diagnostic Performance of 9 Fecal Immunochemical Tests
    Gies, Anton
    Gruner, Laura Fiona
    Schrotz-King, Petra
    Brenner, Hermann
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2019, 17 (09) : 1829 - +
  • [7] Factors associated with false-positive fecal immunochemical tests in a large German colorectal cancer screening study
    Amitay, Efrat L.
    Cuk, Katarina
    Niedermaier, Tobias
    Weigl, Korbinian
    Brenner, Hermann
    INTERNATIONAL JOURNAL OF CANCER, 2019, 144 (10) : 2419 - 2427
  • [8] Equivalency of Fecal Immunochemical Tests and Colonoscopy in Familial Colorectal Cancer Screening
    Quintero, Enrique
    Carrillo, Marta
    Gimeno-Garcia, Antonio Z.
    Hernandez-Guerra, Manuel
    Nicolas-Perez, David
    Alonso-Abreu, Inmaculada
    Luisa Diez-Fuentes, Maria
    Abraira, Victor
    GASTROENTEROLOGY, 2014, 147 (05) : 1021 - +
  • [9] Cost-effectiveness of High-performance Biomarker Tests vs Fecal Immunochemical Test for Noninvasive Colorectal Cancer Screening
    Lansdorp-Vogelaar, Iris
    Goede, S. Lucas
    Bosch, Linda J. W.
    Melotte, Veerle
    Carvalho, Beatriz
    van Engeland, Manon
    Meijer, Gerrit A.
    de Koning, Harry J.
    van Ballegooijen, Marjolein
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2018, 16 (04) : 504 - +
  • [10] A Comparison of Fecal Immunochemical and High-Sensitivity Guaiac Tests for Colorectal Cancer Screening
    Shapiro, Jean A.
    Bobo, Janet K.
    Church, Timothy R.
    Rex, Douglas K.
    Chovnick, Gary
    Thompson, Trevor D.
    Zauber, Ann G.
    Lieberman, David
    Levin, Theodore R.
    Joseph, Djenaba A.
    Nadel, Marion R.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 (11) : 1728 - 1735