Continuous monitoring after second-generation cryoballoon ablation for paroxysmal atrial fibrillation in patients with cardiac implantable electronic devices

被引:5
作者
Choudhury, Rajin [1 ,3 ]
Coutino, Hugo-Enrique [1 ]
Darciuc, Radu [2 ]
Stroker, Erwin [1 ]
De Regibus, Valentina [1 ]
Mugnai, Giacomo [1 ]
Paparella, Gaetano [1 ]
Terasawa, Muryio [1 ]
Varnavas, Varnavas [1 ]
Salghetti, Francesca [1 ]
Iacopino, Saverio [4 ]
Takarada, Ken [1 ]
Abugattas, Juan-Pablo [1 ]
Sieira, Juan [1 ]
Brugada, Pedro [1 ]
de Asmundis, Carlo [1 ]
Chierchia, Gian-Battista [1 ]
机构
[1] Vrije Univ Brussel, Heart Rhythm Management Ctr, Postgrad Course Clin EP & Pacing, Brussels, Belgium
[2] Medpk Int Hosp, Kishinev, Moldova
[3] QE II HSC, Heart Rhythm Serv, Div Cardiol, Halifax, NS, Canada
[4] Villa Maria Cecilia, Villa Maria Care & Res, Cotignola, Italy
关键词
Atrial fibrillation burden; Atrial high rate episode; Cardiac implantable electronic device continuous monitoring; Circumferential pulmonary vein isolation; Second-generation cryoballoon; Subclinical atrial fibrillation; PULMONARY VEIN ISOLATION; RADIOFREQUENCY CATHETER ABLATION; FOLLOW-UP; 3-MINUTE FREEZE; CRYOABLATION; RISK;
D O I
10.1016/j.hrthm.2018.08.015
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The second-generation cryoballoon (CB) is effective in achieving pulmonary vein isolation. Continuous monitoring would eliminate any over- or underestimated freedom from atrial fibrillation (AF) postablation. OBJECTIVE The purpose of this study was to differentiate between arrhythmias occurring after cryoballoon ablation (CBA), detecting true AF in symptomatic patients and detecting silent subclinical AF. METHODS Between June 2012 and January 2015, 54 patients with a preexisting cardiac implantable electronic device (CIED) who had undergone CBA for paroxysmal atrial fibrillation (PAF) were included in our retrospective study. Regular CIED controls, physical examination, and ECG recordings were performed by an experienced cardiologist blinded to the ablation procedure. Data on any hospitalization during follow-up were gathered. Patients were encouraged to note all clinical symptoms during follow-up. RESULTS Continuous monitoring showed a success rate of 83.3% after 1 year and 75.93% after 3 years of follow-up. During the first year, 68% of episodes of palpitations after ablation were due to sinus tachycardia, nonsustained ventricular tachycardia, or supraventricular tachycardia. AF recurrence was detected in 15.6% of asymptomatic patients during follow-up. Total AF burden post-CBA had decreased to 0.64% +/- 4.34% (P<.001) during long-term follow-up of 3.3 years. CONCLUSION Although this is a selected group of patients with a preexisting CIED, continuous monitoring showed freedom from AF in 83.3% of patients post-CBA after 1 year and 75.93% after 3 years of follow-up.
引用
收藏
页码:187 / 196
页数:10
相关论文
共 30 条
[1]   Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies [J].
Andrade, Jason G. ;
Khairy, Paul ;
Guerra, Peter G. ;
Deyell, Marc W. ;
Rivard, Lena ;
Macle, Laurent ;
Thibault, Bernard ;
Talajic, Mario ;
Roy, Denis ;
Dubuc, Marc .
HEART RHYTHM, 2011, 8 (09) :1444-1451
[2]   Improving Stroke Risk Stratification Using the CHADS2 and CHA2DS2-VASc Risk Scores in Patients With Paroxysmal Atrial Fibrillation by Continuous Arrhythmia Burden Monitoring [J].
Boriani, Giuseppe ;
Botto, Giovanni Luca ;
Padeletti, Luigi ;
Santini, Massimo ;
Capucci, Alessandro ;
Gulizia, Michele ;
Ricci, Renato ;
Biffi, Mauro ;
De Santo, Tiziana ;
Corbucci, Giorgio ;
Lip, Gregory Y. H. .
STROKE, 2011, 42 (06) :1768-1770
[3]  
Calkins H, 2017, HEART RHYTHM, V14, pE275, DOI [10.1093/europace/eux274, 10.1016/j.hrthm.2017.05.012, 10.1093/europace/eux275]
[4]   Second-generation cryoballoon ablation for paroxysmal atrial fibrillation: 1-year follow-up [J].
Chierchia, Gian-Battista ;
Di Giovanni, Giacomo ;
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Conte, Giulio ;
Sieira-Moret, Juan ;
Rodriguez-Manero, Moises ;
Casado, Ruben ;
Baltogiannis, Giannis ;
Namdar, Mehdi ;
Saitoh, Yukio ;
Paparella, Gaetano ;
Mugnai, Giacomo ;
Brugada, Pedro .
EUROPACE, 2014, 16 (05) :639-644
[5]   Initial experience of three-minute freeze cycles using the second-generation cryoballoon ablation: acute and short-term procedural outcomes [J].
Chierchia, Gian-Battista ;
Di Giovanni, Giacomo ;
Sieira-Moret, Juan ;
de Asmundis, Carlo ;
Conte, Giulio ;
Rodriguez-Manero, Moises ;
Casado-Arroyo, Ruben ;
Baltogiannis, Giannis ;
Paparella, Gaetano ;
Ciconte, Giuseppe ;
Sarkozy, Andrea ;
Brugada, Pedro .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2014, 39 (02) :145-151
[6]   The 'single big cryoballoon' technique for acute pulmonary vein isolation in patients with paroxysmal atrial fibrillation: a prospective observational single centre study [J].
Chun, Kyoung-Ryul Julian ;
Schmidt, Boris ;
Metzner, Andreas ;
Tilz, Roland ;
Zerm, Thomas ;
Koester, Ilka ;
Fuernkranz, Alexander ;
Koektuerk, Buelent ;
Konstantinidou, Melanie ;
Antz, Matthias ;
Ouyang, Feifan ;
Kuck, Karl Heinz .
EUROPEAN HEART JOURNAL, 2009, 30 (06) :699-709
[7]   Electrophysiological findings following pulmonary vein isolation using radiofrequency catheter guided by contact-force and second-generation cryoballoon: lessons from repeat ablation procedures [J].
Ciconte, Giuseppe ;
Velagic, Vedran ;
Mugnai, Giacomo ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Hunuk, Burak ;
Stroker, Erwin ;
Conte, Giulio ;
Sieira, Juan ;
Di Giovanni, Giacomo ;
Baltogiannis, Giannis ;
Brugada, Pedro ;
de Asmundis, Carlo ;
Chierchia, Gian-Battista .
EUROPACE, 2016, 18 (01) :71-77
[8]   On the Quest for the Best Freeze Predictors of Late Pulmonary Vein Reconnections After Second-Generation Cryoballoon Ablation [J].
Ciconte, Giuseppe ;
Mugnai, Giacomo ;
Sieira, Juan ;
Velagic, Vedran ;
Saitoh, Yukio ;
Irfan, Ghazala ;
Hunuk, Burak ;
Stroeker, Erwin ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Baltogiannis, Giannis ;
Wauters, Kristel ;
Brugada, Pedro ;
de Asmundis, Carlo ;
Chierchia, Gian-Battista .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2015, 8 (06) :1359-1365
[9]   Single 3-minute freeze for second-generation cryoballoon ablation: One-year follow-up after pulmonary vein isolation [J].
Ciconte, Giuseppe ;
de Asmundis, Carlo ;
Sieira, Juan ;
Conte, Giulio ;
Di Giovanni, Giacomo ;
Mugnai, Giacomo ;
Saitoh, Yukio ;
Baltogiannis, Giannis ;
Irfan, Ghazala ;
Coutino-Moreno, Hugo Enrique ;
Hunuk, Burak ;
Velagic, Vedran ;
Brugada, Pedro ;
Chierchia, Gian-Battista .
HEART RHYTHM, 2015, 12 (04) :673-680
[10]   Improved In Vivo Performance of Second-Generation Cryoballoon for Pulmonary Vein Isolation [J].
Coulombe, Nicolas ;
Paulin, Jaime ;
Su, Wilber .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2013, 24 (08) :919-925