Partially covered self-expanding metal stent for unresectable malignant extrahepatic biliary obstruction: results of a large prospective series

被引:12
|
作者
Gomez-Oliva, Cristina [1 ]
Guarner-Argente, Carlos [1 ]
Concepcion, Mar [1 ]
Javier Jimenez, Francisco [2 ]
Rodriguez, Sarbelio [3 ]
Gonzalez-Huix, Ferran [4 ]
Mugica, Fernando [5 ]
Luis Cabriada, Jose [6 ]
Rodriguez, Claudio [7 ]
Guarner Aguilar, Carlos [1 ]
机构
[1] Hosp Santa Creu & Sant Pau, Serv Gastroenterol, Endoscopy Unit, Barcelona 08041, Spain
[2] Hosp Navarra, Serv Gastroenterol, Endoscopy Unit, Pamplona, Spain
[3] Hosp 12 Octubre, Serv Gastroenterol, Endoscopy Unit, E-28041 Madrid, Spain
[4] Hosp Univ Dr Josep Trueta, Serv Gastroenterol, Endoscopy Unit, Girona, Spain
[5] Hosp Donostia Ospitalea, Serv Gastroenterol, Endoscopy Unit, Guipuzcoa, Spain
[6] Hosp Galdakao, Serv Gastroenterol, Endoscopy Unit, Vizcaya, Spain
[7] Hosp Univ Puerta del Mar, Serv Gastroenterol, Endoscopy Unit, Cadiz, Spain
来源
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES | 2012年 / 26卷 / 01期
关键词
Pancreatobiliary; Cholangiopancreatography (ERCP); Cancer digestive; Stenting; Therapeutic; Palliation; COMMON BILE-DUCT; ENDOSCOPIC SPHINCTEROTOMY; RANDOMIZED-TRIAL; DIAMOND STENTS; MANAGEMENT; CHOLECYSTITIS; COMPLICATIONS; STRICTURES; WALLSTENTS; EFFICACY;
D O I
10.1007/s00464-011-1858-z
中图分类号
R61 [外科手术学];
学科分类号
摘要
Endoscopic biliary stenting is a well-established palliative treatment in patients with unresectable malignant biliary strictures. Obstruction of uncovered self-expanding metal stent (SEMS) due to tumor ingrowth is the most frequent complication. Partially covered SEMS might increase stent patency but could favor complications related to stent covering, such as pancreatitis, cholecystitis, and migration. The aim of this study was to evaluate the efficacy and safety of partially covered SEMS in patients with an unresectable malignant biliary stricture. Patients with malignant extrahepatic biliary obstruction treated endoscopically with partially covered SEMS were included in this multicenter, prospective, nonrandomized study. One hundred ninety-nine patients were endoscopically treated with partially covered SEMS in 32 Spanish hospitals. Clinical success after deep cannulation was 96%. Early complications occurred in 4% (3 pancreatitis, 2 cholangitis, 1 hemorrhage, 1 perforation, and 1 cholecystitis). Late complications occurred in 19.5% (18 obstructions, 10 migrations, 6 cholangitis without obstruction, 3 acute cholecystitis, and 2 pancreatitis), with no tumor ingrowth in any case. Median stent patency was 138.9 +/- 112.6 days. One-year actuarial probability of stent patency was 70% and that of nonmigration was 86%. Multivariate analysis showed adjuvant radio- or chemotherapy as the only independent predictive factor of stent patency and previous insertion of a biliary stent was the only predictive factor of migration. The partially covered SEMS was easily inserted, had a high clinical success rate, and prevented tumor ingrowth. The incidence of possible complications related to stent coverage, namely, migration, pancreatitis, and cholecystitis, was lower than in previously published series.
引用
收藏
页码:222 / 229
页数:8
相关论文
共 50 条
  • [31] Short-term results of self-expanding metal stents for acute malignant large bowel obstruction
    Kobborg, M.
    Broholm, M.
    Frostberg, E.
    Jeppesen, M.
    Gogenur, I.
    COLORECTAL DISEASE, 2017, 19 (10) : O365 - O371
  • [32] Modified non-flared fully covered self-expandable metal stent versus plastic stent for preoperative biliary drainage in patients with resectable malignant biliary obstruction
    Lee, Hyun Woo
    Moon, Jong Ho
    Lee, Yun Nah
    Chung, Jun Chul
    Lee, Tae Hoon
    Choi, Moon Han
    Cha, Sang-Woo
    Cho, Young Deok
    Park, Sang-Heum
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2019, 34 (09) : 1590 - 1596
  • [33] Efficacy and safety of uncovered self-expandable metal stents for distal malignant biliary obstruction in unresectable non-pancreatic cancer
    Niiya, Fumitaka
    Tamai, Naoki
    Yamawaki, Masataka
    Noda, Jun
    Azami, Tetsushi
    Takano, Yuichi
    Nishimoto, Fumiya
    Nagahama, Masatsugu
    DEN OPEN, 2025, 5 (01):
  • [34] Adverse events of self-expandable metal stent placement for malignant distal biliary obstruction: a large multicenter study
    Tamura, Takashi
    Yamai, Takuo
    Uza, Norimitsu
    Yamasaki, Tomoaki
    Masuda, Atsuhiro
    Tomooka, Fumimasa
    Maruyama, Hirotsugu
    Shigekawa, Minoru
    Ogura, Takeshi
    Kuriyama, Katsutoshi
    Asada, Masanori
    Matsumoto, Hisakazu
    Takenaka, Mamoru
    Mandai, Koichiro
    Osaki, Yui
    Matsumoto, Kengo
    Sanuki, Tsuyoshi
    Shiomi, Hideyuki
    Yamagata, Yosuke
    Doi, Toshifumi
    Inatomi, Osamu
    Nakanishi, Fumihiko
    Emori, Tomoya
    Shimatani, Masaaki
    Asai, Satoshi
    Fujigaki, Seiji
    Shimokawa, Toshio
    Kitano, Masayuki
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (01) : 61 - 72.e8
  • [35] Retrospective evaluation of slim fully covered self-expandable metallic stent for unresectable malignant hilar biliary obstruction
    Takahashi, Sho
    Fujisawa, Toshio
    Ushio, Mako
    Fukuma, Taito
    Suzuki, Akinori
    Takasaki, Yusuke
    Ito, Koichi
    Tomishima, Ko
    Ishii, Shigeto
    Isayama, Hiroyuki
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (03) : 408 - 415
  • [36] Distal malignant biliary obstruction: a prospective randomised trial comparing plastic and uncovered self-expanding metal stents in the palliation of symptomatic jaundice
    Bernon, M. M.
    Shaw, J.
    Burmeister, S.
    Chinnery, G.
    Hofmeyr, S.
    Kloppers, J. C.
    Jonas, E.
    Krige, J. E. J.
    SOUTH AFRICAN JOURNAL OF SURGERY, 2018, 56 (01) : 30 - 34
  • [37] Comparison of 8-and 10-mm diameter fully covered self-expandable metal stents: A multicenter prospective study in patients with distal malignant biliary obstruction
    Kawashima, Hiroki
    Hashimoto, Senju
    Ohno, Eizaburo
    Ishikawa, Takuya
    Morishima, Tomomasa
    Matsubara, Hiroshi
    Sugimoto, Hiroyuki
    Nonogaki, Koji
    Kanamori, Akira
    Hara, Kazuo
    Kuwahara, Takamichi
    Nakamura, Masanao
    Miyahara, Ryoji
    Ishigami, Masatoshi
    Ando, Masahiko
    Hirooka, Yoshiki
    DIGESTIVE ENDOSCOPY, 2019, 31 (04) : 439 - 447
  • [38] Insertion of fully covered self-expanding metal stents in benign biliary diseases
    Omodeo, Mariana
    Malaga, Ignacio
    Manazzoni, Dante
    Curvale, Cecilia
    de Maria, Julio
    Guidi, Martin
    Matano, Raul
    REVISTA ESPANOLA DE ENFERMEDADES DIGESTIVAS, 2018, 110 (01) : 30 - 34
  • [39] Covered versus uncovered metal stent for endoscopic drainage of a malignant distal biliary obstruction: Meta-analysis
    Yamashita, Yasunobu
    Tachikawa, Ayaka
    Shimokawa, Toshio
    Yamazaki, Hirofumi
    Itonaga, Masahiro
    Sakai, Yuji
    Sugiyama, Harutoshi
    Nakai, Yousuke
    Tanaka, Kiyohito
    Isayama, Hiroyuki
    Kitano, Masayuki
    DIGESTIVE ENDOSCOPY, 2022, 34 (05) : 938 - 951
  • [40] Covered metallic stenting for malignant distal biliary obstruction: clinical results according to stent type
    Isayama, Hiroyuki
    Nakai, Yousuke
    Kawakubo, Kazumichi
    Kogure, Hirofumi
    Togawa, Osamu
    Hamada, Tsuyoshi
    Ito, Yukiko
    Sasaki, Takashi
    Yamamoto, Natsuyo
    Sasahira, Naoki
    Hirano, Kenji
    Tsujino, Takeshi
    Tada, Minoru
    Koike, Kazuhiko
    JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2011, 18 (05) : 673 - 677