Plateletpheresis-associated lymphopenia in frequent platelet donors

被引:25
作者
Gansner, John M. [1 ,2 ]
Rahmani, Mahboubeh [3 ]
Jonsson, A. Helena [2 ,4 ]
Fortin, Brooke M. [1 ]
Brimah, Idayat [5 ]
Ellis, Martha [6 ]
Smeland-Wagman, Robin [6 ]
Li, Zhihan J. [4 ]
Schenkel, Jason M. [2 ,6 ]
Brenner, Michael B. [2 ,4 ]
Yefidoff-Freedman, Revital [1 ,2 ]
Sloan, Steven R. [2 ,6 ,7 ]
Berliner, Nancy [1 ,2 ]
Issa, Nicolas C. [2 ,8 ]
Baden, Lindsey R. [2 ,8 ]
Longo, Dan L. [1 ,2 ]
Wesemann, Duane R. [2 ,4 ]
Neuberg, Donna [9 ]
Rao, Deepak A. [2 ,4 ]
Kaufman, Richard M. [2 ,6 ]
机构
[1] Brigham & Womens Hosp, Dept Med, Div Hematol, Boston, MA 02115 USA
[2] Harvard Med Sch, Boston, MA USA
[3] Dalhousie Univ, Dept Pathol, Div Hematopathol, Halifax, NS, Canada
[4] Brigham & Womens Hosp, Dept Med, Div Rheumatol Immunol & Allergy, 75 Francis St, Boston, MA 02115 USA
[5] Brigham & Womens Hosp, Ctr Clin Invest, 75 Francis St, Boston, MA 02115 USA
[6] Brigham & Womens Hosp, Dept Pathol, 75 Francis St, Boston, MA 02115 USA
[7] Boston Childrens Hosp, Dept Lab Med, Boston, MA USA
[8] Brigham & Womens Hosp, Dept Med, Div Infect Dis, 75 Francis St, Boston, MA 02115 USA
[9] Dana Farber Canc Inst, Dept Biostat & Computat Biol, Boston, MA 02115 USA
基金
美国国家卫生研究院;
关键词
LEUKOREDUCTION SYSTEM CHAMBERS; MONONUCLEAR-CELLS; LYMPHOCYTE SUBSETS; BLOOD COLLECTION; APHERESIS; TRANSFUSION; POPULATION; DONATION; NUMBERS; MEMORY;
D O I
10.1182/blood-2018-09-873125
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
More than 1 million apheresis platelet collections are performed annually in the United States. After 2 healthy plateletpheresis donors were incidentally found to have low CD4(+) T-lymphocyte counts, we investigated whether plateletpheresis causes lymphopenia. We conducted a cross-sectional single-center study of platelet donors undergoing plateletpheresis with the Trima Accel, which removes leukocytes continuously with its leukoreduction system chamber. We recruited 3 groups of platelet donors based on the total number of plateletpheresis sessions in the prior 365 days: 1 or 2, 3 to 19, or 20 to 24. CD4(+) T-lymphocyte counts were < 200 cells per microliter in 0/20, 2/20, and 6/20 donors, respectively (P < .019), and CD8(+) T-lymphocyte counts were low in 0/20, 4/20, and 11/20 donors, respectively (P <.001). The leukoreduction system chamber's lymphocyte-extraction efficiency was similar to 15% to 20% for all groups. Immunophenotyping showed decreases in naive CD4(+) T-lymphocyte and T helper 17 (Th17) cell percentages, increases in CD4(+) and CD8(+) effector memory, Th1, and regulatory T cell percentages, and stable naive CD8(+) and Th2 percentages across groups. T-cell receptor repertoire analyses showed similar clonal diversity in all groups. Donor screening questionnaires supported the good health of the donors, who tested negative at each donation for multiple pathogens, including HIV. Frequent plateletpheresis utilizing a leukoreduction system chamber is associated with CD4(+) and CD8(+) T-cell lymphopenia in healthy platelet donors. The mechanism may be repeated extraction of these cells during plateletpheresis. The cytopenias do not appear to be harmful.
引用
收藏
页码:605 / 614
页数:10
相关论文
共 33 条
[1]  
[Anonymous], 2007, GUIDANCE IND FDA REV
[2]   Reference values for peripheral blood lymphocyte phenotypes applicable to the healthy adult population in Switzerland [J].
Bisset, LR ;
Lung, TL ;
Kaelin, M ;
Ludwig, E ;
Dubs, RW .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2004, 72 (03) :203-212
[3]   Homeostatic proliferation and survival of naive and memory T cells [J].
Boyman, Onur ;
Letourneau, Sven ;
Krieg, Carsten ;
Sprent, Jonathan .
EUROPEAN JOURNAL OF IMMUNOLOGY, 2009, 39 (08) :2088-2094
[4]   IL-7: maintaining T-cell memory and achieving homeostasis [J].
Bradley, LM ;
Haynes, L ;
Swain, SL .
TRENDS IN IMMUNOLOGY, 2005, 26 (03) :172-176
[5]   A novel source of viable peripheral blood mononuclear cells from leukoreduction system chambers [J].
Dietz, Allan B. ;
Bulur, Peggy A. ;
Emery, Richard L. ;
Winters, Jeffrey L. ;
Epps, Dennis E. ;
Zubair, Abba C. ;
Vuk-Pavlovic, Stanimir .
TRANSFUSION, 2006, 46 (12) :2083-2089
[6]   Apheresis technology correlates with bacterial contamination of platelets and reported septic transfusion reactions [J].
Eder, Anne F. ;
Dy, Beth A. ;
DeMerse, Barbara ;
Wagner, Stephen J. ;
Stramer, Susan L. ;
O'Neill, E. Mary ;
Herron, Ross M. .
TRANSFUSION, 2017, 57 (12) :2969-2976
[7]   Continued decline in blood collection and transfusion in the United States-2015 [J].
Ellingson, Katherine D. ;
Sapiano, Mathew R. P. ;
Haass, Kathryn A. ;
Savinkina, Alexandra A. ;
Baker, Misha L. ;
Chung, Koo-Whang ;
Henry, Richard A. ;
Berger, James J. ;
Kuehnert, Matthew J. ;
Basavaraju, Sridhar V. .
TRANSFUSION, 2017, 57 :1588-1598
[8]   Do most lymphocytes in humans really reside in the gut? [J].
Ganusov, Vitaly V. ;
De Boer, Rob J. .
TRENDS IN IMMUNOLOGY, 2007, 28 (12) :514-518
[9]   Research electronic data capture (REDCap)-A metadata-driven methodology and workflow process for providing translational research informatics support [J].
Harris, Paul A. ;
Taylor, Robert ;
Thielke, Robert ;
Payne, Jonathon ;
Gonzalez, Nathaniel ;
Conde, Jose G. .
JOURNAL OF BIOMEDICAL INFORMATICS, 2009, 42 (02) :377-381
[10]   A randomized controlled trial comparing the frequency of acute reactions to plasma-removed platelets and prestorage WBC-reduced platelets [J].
Heddle, NM ;
Blajchman, MA ;
Meyer, RM ;
Lipton, JH ;
Walker, IR ;
Sher, GD ;
Constantini, LA ;
Patterson, B ;
Roberts, RS ;
Thorpe, KE ;
Levine, MN .
TRANSFUSION, 2002, 42 (05) :556-566