Comparison of implant stability measurement devices for bone-anchored hearing aid systems

被引:0
作者
Westover, Lindsey [1 ]
Faulkner, Gary [2 ]
Hodgetts, William [3 ]
Raboud, Don [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
[2] Glenrose Rehabil Hosp, Rehabil Res & Technol Dev, Edmonton, AB, Canada
[3] Univ Alberta, Commun Sci & Disorders, Rehabil Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
RESONANCE FREQUENCY-ANALYSIS; OSSEOINTEGRATED IMPLANTS; CONDUCTION DEVICES; SURVIVAL; COMPLICATIONS; TOLERABILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The success of implants for bone-anchored hearing aids (BAHA) relies on proper osseointegration at the bone-implant interface. Clinical evaluation of implant stability is important in prescribing loading, identifying the risk of failure, and monitoring the long-term health of the implant. Purpose. The purpose of this in vitro study was to evaluate 2 measurement systems for BAHA implant stability: the most commonly used, Osstell implant stability quotient (ISQ), and a newly developed advance system for implant stability testing (ASIST). Material and methods. BAHA implants (Oticon Medical Ponto and Cochlear BAHA Connect systems) were installed in plastic materials with adhesive to simulate implants integrated in bone with varying levels of interface stiffness. Different lengths of BAHA abutments were used with each implant specimen, and stability measurements were obtained with both the Osstell ISQ and the ASIST systems. The measurement systems were evaluated in terms of sensitivity to differences in interface stiffness and the effect of abutment length on the stability measurement. Repeated measures ANOVA followed by post hoc t tests were used for the comparisons with a Bonferroni adjusted alpha value of.05/15 = .003 to control for potential type 1 errors. Results. Changing the abutment length of a single implant installation had minimal effect on the ASIST stability coefficient, whereas large variations were observed in the Osstell implant stability quotient (ISQ). The Osstell showed a clear relationship of decreasing ISQ with increasing abutment length for both the Oticon Medical and the Cochlear implant systems. Both the ASIST and the Osstell were found to be sensitive to changes in interface properties, with the ASIST being more sensitive to these changes. Conclusions. The ASIST system is more sensitive to changes in interface properties and shows smaller variation because of changes in abutment length than the Osstell ISQ system.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 50 条
[41]   Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning [J].
Hultcrantz, Malou .
BIOMED RESEARCH INTERNATIONAL, 2015, 2015
[42]   Percutaneous Bone-Anchored Hearing Implant Surgery: Do Syndromic Children Have More Adverse Perioperative Outcomes? [J].
Salameh, Samer ;
El-Khoury, Sabine ;
Bezdjian, Aren ;
Roy, Catherine F. ;
Khneisser, Edwina ;
Bianchi, Marco ;
Daniel, Sam J. .
OTOLOGY & NEUROTOLOGY, 2023, 44 (07) :E504-E511
[43]   Bone-Anchored Hearing Implants: Surgical and Audiological Comparison of Different Surgical Techniques [J].
Topcu, Merve Torun ;
Mutlu, Basak ;
Celik, Serdal ;
Celikgun, Bahtiyar ;
Mutlu, Ahmet ;
Kalcioglu, M. Tayyar .
INTERNATIONAL ARCHIVES OF OTORHINOLARYNGOLOGY, 2022, 26 (04) :649-656
[44]   Has the use of the linear incision reduced skin complications in bone-anchored hearing aid implantation? [J].
Roplekar, R. ;
Lim, A. ;
Hussain, S. S. M. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2016, 130 (06) :541-544
[45]   High Body Mass Index as a Risk Factor for Skin Overgrowth With the Bone-Anchored Hearing Aid [J].
Berenholz, Leonard P. ;
Burkey, John M. ;
Lippy, William H. .
OTOLOGY & NEUROTOLOGY, 2010, 31 (03) :430-432
[46]   Unusual complication following trauma to a bone-anchored hearing aid: case report and literature review [J].
McDermott, A-L ;
Barraclough, J. ;
Reid, A. P. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2009, 123 (03) :348-350
[47]   An approach to bilateral bone-anchored hearing aid surgery in children: contralateral placement of sleeper fixture [J].
Bernstein, J. M. ;
Sheehan, P. Z. .
JOURNAL OF LARYNGOLOGY AND OTOLOGY, 2009, 123 (05) :555-557
[48]   Experience of bone-anchored hearing aid implantation in children younger than 5 years of age [J].
Amonoo-Kuofi, Kwamena ;
Kelly, Andrea ;
Neeff, Michel ;
Brown, Colin R. S. .
INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2015, 79 (04) :474-480
[49]   Epidural Hematoma After Tympanomastoidectomy and Bone-Anchored Hearing Aid (BAHA) Placement: Case Report [J].
Mesfin, Fassil B. ;
Perkins, Nora W. ;
Brook, Christopher ;
Foyt, David ;
German, John W. .
NEUROSURGERY, 2010, 67 (05) :E1451-E1453
[50]   Clinical evaluation of a new laser-ablated titanium implant for bone-anchored hearing in 34 patients: 1-year experience [J].
Kruyt, I. J. ;
Banga, R. ;
Banerjee, A. ;
Mylanus, E. A. M. ;
Hol, M. K. S. .
CLINICAL OTOLARYNGOLOGY, 2018, 43 (02) :761-764