Comparison of implant stability measurement devices for bone-anchored hearing aid systems

被引:0
|
作者
Westover, Lindsey [1 ]
Faulkner, Gary [2 ]
Hodgetts, William [3 ]
Raboud, Don [1 ]
机构
[1] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
[2] Glenrose Rehabil Hosp, Rehabil Res & Technol Dev, Edmonton, AB, Canada
[3] Univ Alberta, Commun Sci & Disorders, Rehabil Med, Edmonton, AB, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
RESONANCE FREQUENCY-ANALYSIS; OSSEOINTEGRATED IMPLANTS; CONDUCTION DEVICES; SURVIVAL; COMPLICATIONS; TOLERABILITY;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The success of implants for bone-anchored hearing aids (BAHA) relies on proper osseointegration at the bone-implant interface. Clinical evaluation of implant stability is important in prescribing loading, identifying the risk of failure, and monitoring the long-term health of the implant. Purpose. The purpose of this in vitro study was to evaluate 2 measurement systems for BAHA implant stability: the most commonly used, Osstell implant stability quotient (ISQ), and a newly developed advance system for implant stability testing (ASIST). Material and methods. BAHA implants (Oticon Medical Ponto and Cochlear BAHA Connect systems) were installed in plastic materials with adhesive to simulate implants integrated in bone with varying levels of interface stiffness. Different lengths of BAHA abutments were used with each implant specimen, and stability measurements were obtained with both the Osstell ISQ and the ASIST systems. The measurement systems were evaluated in terms of sensitivity to differences in interface stiffness and the effect of abutment length on the stability measurement. Repeated measures ANOVA followed by post hoc t tests were used for the comparisons with a Bonferroni adjusted alpha value of.05/15 = .003 to control for potential type 1 errors. Results. Changing the abutment length of a single implant installation had minimal effect on the ASIST stability coefficient, whereas large variations were observed in the Osstell implant stability quotient (ISQ). The Osstell showed a clear relationship of decreasing ISQ with increasing abutment length for both the Oticon Medical and the Cochlear implant systems. Both the ASIST and the Osstell were found to be sensitive to changes in interface properties, with the ASIST being more sensitive to these changes. Conclusions. The ASIST system is more sensitive to changes in interface properties and shows smaller variation because of changes in abutment length than the Osstell ISQ system.
引用
收藏
页码:178 / 184
页数:7
相关论文
共 50 条
  • [1] Longitudinal Evaluation of Bone-Anchored Hearing Aid Implant Stability Using the Advanced System for Implant Stability Testing (ASIST)
    Westover, Lindsey
    Faulkner, Gary
    Hodgetts, William
    Kamal, Fraaz
    Lou, Edmond
    Raboud, Don
    OTOLOGY & NEUROTOLOGY, 2018, 39 (06) : e489 - e495
  • [2] Stability and survival of bone-anchored hearing aid implant systems in post-irradiated patients
    Mark D. Wilkie
    Kathryn A. Lightbody
    Ali A. Salamat
    Kalyan M. Chakravarthy
    David A. Luff
    Robert H. Temple
    European Archives of Oto-Rhino-Laryngology, 2015, 272 : 1371 - 1376
  • [3] Stability and survival of bone-anchored hearing aid implant systems in post-irradiated patients
    Wilkie, Mark D.
    Lightbody, Kathryn A.
    Salamat, Ali A.
    Chakravarthy, Kalyan M.
    Luff, David A.
    Temple, Robert H.
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2015, 272 (06) : 1371 - 1376
  • [4] Bone-Anchored Hearing Implant Loading at 3 Weeks: Stability and Tolerability After 6 Months
    Faber, Hubert T.
    Dun, Catharina A. J.
    Nelissen, Rik C.
    Mylanus, Emmanuel A. M.
    Cremers, Cor W. R. J.
    Hol, Myrthe K. S.
    OTOLOGY & NEUROTOLOGY, 2013, 34 (01) : 104 - 110
  • [5] Bone-Anchored Hearing Aid: A Comparison of Surgical Techniques
    van de Berg, Raymond
    Stokroos, Robert J.
    Hof, Janny R.
    Chenault, Michelene N.
    OTOLOGY & NEUROTOLOGY, 2010, 31 (01) : 129 - 135
  • [6] Implant Losses for the Bone-Anchored Hearing Devices Are More Frequent in Some Patients
    Larsson, Anna
    Tjellstrom, Anders
    Stalfors, Joacim
    OTOLOGY & NEUROTOLOGY, 2015, 36 (02) : 336 - 340
  • [7] Bone-Anchored Hearing Aid Implant Location in Relation to Skin Reactions
    Faber, Hubert T.
    de Wolf, Maarten J. F.
    de Rooy, Jacky W. J.
    Hol, Myrthe K. S.
    Cremers, Cor W. R. J.
    Mylanus, Emmanuel A. M.
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2009, 135 (08) : 742 - 747
  • [8] Bone-Anchored Hearing Aid Surgery in Older Adults: Implant Loss and Skin Reactions
    de Wolf, Maarten J. F.
    Hol, Myrthe K. S.
    Mylanus, Emmanuel A. M.
    Cremers, Cor W. R. J.
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2009, 118 (07) : 525 - 531
  • [9] Resonance Frequency Analysis Identifies Implant- and Host-Related Factors Associated With Bone-Anchored Hearing Implant Stability
    Bezdjian, Aren
    Mikolajewicz, Nicholas
    Denton, Carolyn
    Bouchard, Alice
    Rummler, Maximilian
    Gludovatz, Bernd
    Shin, Mihee
    Zimmermann, Elizabeth
    Salameh, Samer
    Daniel, Sam J.
    Willie, Bettina M.
    OTOLOGY & NEUROTOLOGY, 2024, 45 (06) : 676 - 683
  • [10] Complications of bone-anchored hearing aid implantation
    Hobson, J. C.
    Roper, A. J.
    Andrew, R.
    Rothera, M. P.
    Hill, P.
    Green, K. M.