Unstable subtrochanteric fractures - gamma nail versus dynamic condylar screw

被引:25
作者
Pakuts, AJ [1 ]
机构
[1] Hosp Reg Coquimbo, Dept Orthopaed, La Serena, Chile
关键词
D O I
10.1007/s00264-003-0497-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We reviewed the operative treatment of subtrochanteric fractures. Before 1999, 15 fractures were treated with a dynamic condylar screw (DCS) and after 1999, 11 fractures were treated with a gamma nail (GN). The mean age of all patients was 70 (31-92) years, and the mean follow up was 16 (9-30) months for the DCS group and 14 (6-26) months for the GN group. All fractures united. There were no infections or implant cut out. In the DCS group, there was one malunion in varus and one late fracture of the implant. In the GN group, there was one malunion in internal rotation and three intraoperative fractures. Functional evaluation showed no significant differences in pain, range of movement, or walking ability, but recovery was significantly earlier in the GN group.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 18 条
[1]   Prospective randomized controlled trial of an intramedullary nail versus dynamic screw and plate for intertrochanteric fractures of the femur [J].
Adams, CI ;
Robinson, CM ;
Court-Brown, CM ;
McQueen, MM .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (06) :394-400
[2]   Intertrochanteric-subtrochanteric fractures:: Treatment with the long gamma nail [J].
Barquet, A ;
Francescoli, L ;
Rienzi, D ;
López, L .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2000, 14 (05) :324-328
[3]   The long gamma nail: a DGH experience [J].
Edwards, SA ;
Pandit, HG ;
Clarke, HJ .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2000, 31 (09) :701-709
[4]   Comparative dynamic evaluation of the sliding/characteristics of the Gamma nail: a biomechanical analysis [J].
Haynes, RC ;
Miles, AW .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 1997, 211 (05) :411-417
[5]   Failure of femoral head fixation: a cadaveric analysis of lag screw cut-out with the gamma locking nail and AO dynamic hip screw [J].
Haynes, RC ;
Poll, RG ;
Miles, AW ;
Weston, RB .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1997, 28 (5-6) :337-341
[6]   Minimal invasive treatment of proximal femur fractures with the long gamma nail: Indication, technique, results [J].
Hotz, TK ;
Zellweger, R ;
Kach, KP .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1999, 47 (05) :942-945
[7]   The standard Gamma nail:: A critical analysis of 1,000 cases [J].
Kukla, C ;
Heinz, T ;
Gaebler, C ;
Heinze, G ;
Vécsei, V .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2001, 51 (01) :77-83
[8]   Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: A comparative study with the Gamma nail and compression hip screw [J].
Madsen, JE ;
Naess, L ;
Aune, AK ;
Alho, A ;
Ekeland, A ;
Stromsoe, K .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (04) :241-248
[9]  
MAHOMED N, 1994, CLIN ORTHOP RELAT R, V304, P280
[10]   Treatment of intertrochanteric fracture with the Gamma AP locking nail or by a compression hip screw - a randomised prospective trial [J].
Park, SR ;
Kang, JS ;
Kim, HS ;
Lee, WH .
INTERNATIONAL ORTHOPAEDICS, 1998, 22 (03) :157-160