Wide area oscillation damping controller for DFIG using WAMS with delay compensation

被引:28
作者
Simon, Likin [1 ]
Swarup, K. Shanti [1 ]
Ravishankar, Jayashri [2 ]
机构
[1] Indian Inst Technol, Elect Engn Dept, Madras, Tamil Nadu, India
[2] Univ New South Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
关键词
phasor measurement; oscillations; asynchronous generators; control system synthesis; power generation control; wind turbines; power system stability; power system control; damping; power system interconnection; wind power plants; power system measurement; wide area oscillation; DFIG; delay compensation; system stability; induction generator based wind turbines; remote location; local signals; complete oscillation information; wide area damping control; local area oscillations; inter area oscillations; wide area measurement systems; phasor measurement units; synchrophasors; centralised controller; inter-area; local oscillatory modes; damping controller parameters; local power system stabiliser settings; system modal damping; WAMS based controller; controller design process; WADC algorithm addresses this issue; delayed time; optimisation algorithm; comprehensive case studies; noisy delayed communication signals; FED INDUCTION GENERATOR; POWER-SYSTEM; DESIGN; PENETRATION; STABILITY;
D O I
10.1049/iet-rpg.2018.5192
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Several studies have reported the improvement of system stability with a doubly-fed induction generator (DFIG) based wind turbines. Due to the remote location of DFIG, the local signals measured may not contain the complete oscillation information of the power system. This study describes an optimisation enabled wide area damping control (WADC) for DFIG to mitigate both local and inter area oscillations. Wide area measurement systems (WAMSs) which include phasor measurement units and synchrophasors are used for a centralised controller for damping inter-area and local oscillatory modes. The proposed damping controller parameters are optimised along with the local power system stabiliser settings for maximising the impact on system modal damping. The challenging shortcoming of WAMS based controller is the variable communication latency which can adversely affect the controller if not accounted in the controller design process. The proposed WADC algorithm addresses this issue and compensates for the delayed and time stamped error signals. The variable latencies are normalised in the optimisation algorithm in the design of controller parameters. The proposed algorithm is verified with transient simulation in PSCAD/EMTDC for the most severe three-phase faults. A set of comprehensive case studies are performed to analyse the effectiveness of the proposed algorithm for the noisy, delayed communication signals.
引用
收藏
页码:128 / 137
页数:10
相关论文
共 40 条
  • [31] Power system stabiliser and flexible alternating current transmission systems controller coordinated design using adaptive velocity update relaxation particle swarm optimisation algorithm in multi-machine power system
    Shahgholian, Ghazanfar
    Movahedi, Amir
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (08) : 1860 - 1868
  • [32] Sensorless Maximum Power Point Tracking of Wind by DFIG Using Rotor Position Phase Lock Loop (PLL)
    Shen, Baike
    Mwinyiwiwa, Bakari
    Zhang, Yongzhen
    Ooii, Boon-Teck
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (3-4) : 942 - 951
  • [33] Adaptive wide-area power oscillation damper design for photovoltaic plant considering delay compensation
    Shen, Yu
    Yao, Wei
    Wen, Jinyu
    He, Haibo
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (18) : 4511 - 4519
  • [34] Simon L, 2015, ASIA-PAC POWER ENERG
  • [35] Coordinated Robust Control of DFIG Wind Turbine and PSS for Stabilization of Power Oscillations Considering System Uncertainties
    Surinkaew, Tossaporn
    Ngamroo, Issarachai
    [J]. IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (03) : 823 - 833
  • [36] A Divide-by-Difference-Filter Based Algorithm for Estimation of Generator Rotor Angle Utilizing Synchrophasor Measurements
    Tripathy, Praveen
    Srivastava, S. C.
    Singh, S. N.
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2010, 59 (06) : 1562 - 1570
  • [37] Input-Output Analysis and Decentralized Optimal Control of Inter-Area Oscillations in Power Systems
    Wu, Xiaofan
    Doerfler, Florian
    Jovanovic, Mihailo R.
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (03) : 2434 - 2444
  • [38] Dominant low-frequency oscillation modes tracking and parameter optimisation of electrical power system using modified Prony method
    Xia, Xin
    Li, Chaoshun
    Ni, Wei
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2017, 11 (17) : 4358 - 4364
  • [39] Wide-Area Damping Controller for Power System Interarea Oscillations: A Networked Predictive Control Approach
    Yao, Wei
    Jiang, Lin
    Wen, Jinyu
    Wu, Qinghua
    Cheng, Shijie
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2015, 23 (01) : 27 - 36
  • [40] Adaptive wide-area damping control scheme with stochastic subspace identification and signal time delay compensation
    Zhang, P.
    Yang, D. Y.
    Chan, K. W.
    Cai, G. W.
    [J]. IET GENERATION TRANSMISSION & DISTRIBUTION, 2012, 6 (09) : 844 - 852