Audiogram configurations among older adults: Prevalence and relation to self-reported hearing problems

被引:30
作者
Hannula, Samuli [1 ]
Bloigu, Risto [2 ]
Majamaa, Kari [1 ]
Sorri, Martti [1 ]
Maki-Torkko, Elina [1 ,3 ,4 ]
机构
[1] Univ Oulu, Dept Clin Med, FI-90014 Oulu, Finland
[2] Univ Oulu, Med Informat Grp, FI-90014 Oulu, Finland
[3] Linkoping Univ, Dept Clin & Expt Med Tech Audiol, Linkoping, Sweden
[4] Dept ENT Head Neck Surg UHL, Linkoping, Sweden
关键词
Hearing; tinnitus; hyperacusis; adult; audiogram; configuration; shape; AUDIOMETRIC CONFIGURATION; THRESHOLD LEVELS; POPULATION; PRESBYCUSIS; IMPAIRMENT; PATHOLOGY; TINNITUS; HEALTH; SHAPE; GENE;
D O I
10.3109/14992027.2011.593562
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Objective : There are only a few population-based epidemiological studies on audiogram configurations among adults. The aim of this study was to investigate the prevalence of different audiogram configurations among older adults. In addition, audiogram configurations among subjects reporting hearing problems were examined. Design : Cross-sectional, population-based, unscreened epidemiological study among older adults. Study sample : The subjects (850), aged 54-66 years, were randomly sampled from the population register. A questionnaire survey, an otological examination, and pure-tone audiometry were performed. Results : The most prevalent audiogram configuration among men was high-frequency steeply sloping (65.3% left ear, 51.2% right ear) and among women, high-frequency gently sloping (33.0% left ear, 31.5% right ear). There were significantly more flat configurations among women than among men. Unclassified audiograms were common especially among women (17.5%). Subjects reporting hearing difficulties, difficulties in following conversation in noise, or tinnitus, more often had a high-frequency steeply sloping configuration than those not reporting. Conclusions : High-frequency sloping audiogram configurations were common among older adults, and a high-frequency steeply sloping configuration was common among those reporting hearing problems.
引用
收藏
页码:793 / 801
页数:9
相关论文
共 46 条
[1]   Presbycusis phenotypes form a heterogeneous continuum when ordered by degree and configuration of hearing loss [J].
Allen, Paul D. ;
Eddins, David A. .
HEARING RESEARCH, 2010, 264 (1-2) :10-20
[2]  
[Anonymous], 1988, BRIT J AUDIOL, V22, P123, DOI [DOI 10.3109/03005368809077807, 10.3109/03005368809077807]
[3]  
BEAGLEHOLE R, 2003, WORLD HLTH REPORT 20, P14
[4]  
CARHART R, 1945, LARYNGOSCOPE, V55, P640
[5]   Hearing impairment and health-related quality of life: The Blue Mountains Hearing Study [J].
Chia, Ee-Munn ;
Wang, Jie Jin ;
Rochtchina, Elena ;
Cumming, Robert R. ;
Newall, Philip ;
Mitchell, Paul .
EAR AND HEARING, 2007, 28 (02) :187-195
[6]   Prevalence of Hearing Impairment by Gender and Audiometric Configuration: Results from the National Health and Nutrition Examination Survey (1999-2004) and the Keokuk County Rural Health Study (1994-1998) [J].
Ciletti, Lindsay ;
Flamme, Gregory A. .
JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2008, 19 (09) :672-685
[7]  
Cruickshanks KJ, 1998, AM J EPIDEMIOL, V148, P879
[8]  
Davis A., 1995, Hearing in adults
[10]  
Demeester K, 2007, B-ENT, P37