Z-source T-type inverter for renewable energy systems with proportional resonant controller

被引:32
作者
Ozdemir, Saban [1 ]
机构
[1] Gazi Univ, Vocat Sch Tech Sci, Ankara, Turkey
关键词
Z-source inverter; T-type inverter; PR controller; Grid interactive inverter; GRID-CONNECTED INVERTERS; POWER POINT TRACKING; Z-SOURCE NETWORK; 3-LEVEL; CONVERTER; QUALITY;
D O I
10.1016/j.ijhydene.2016.01.140
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this study, a novel z-source T-type inverter for grid connected renewable energy system is proposed. The proposed system has ability of boosting voltage level without any additional DC DC converter or transformer through the z-impedance network. The size of the system is reduced by eliminating DC DC converter or step-up transformer requirement. Furthermore, an additional improvement in system efficiency is obtained by using T-type inverter structure which is more efficient than the conventional two-level inverter or three-level neutral point clamped inverter. Inverter output currents are controlled by the proportional resonant controller. MATLAB/Simulink simulations show that, fast dynamic response is obtained and steady state error is eliminated. In addition, the inverter output currents are in sinusoidal waveforms and synchronous with the grid frequency and phase. Besides, total harmonic distortion values of the inverter currents are measured as 2.41% which meets the international standards such as IEC61727 and IEEE1547. (C) 2016 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:12591 / 12602
页数:12
相关论文
共 33 条
[2]   Three-phase three-level grid interactive inverter with fuzzy logic based maximum power point tracking controller [J].
Altin, Necmi ;
Ozdemir, Saban .
ENERGY CONVERSION AND MANAGEMENT, 2013, 69 :17-26
[3]   Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy [J].
Choi, Ui-Min ;
Blaabjerg, Frede ;
Lee, Kyo-Beum .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) :2660-2673
[4]   PV output power fluctuations smoothing: The MYRTE platform experience [J].
Darras, C. ;
Muselli, M. ;
Poggi, P. ;
Voyant, C. ;
Hoguet, J-C ;
Montignac, F. .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2012, 37 (19) :14015-14025
[5]   Space-Vector-Modulated Three-Level Inverters With a Single Z-Source Network [J].
Effah, Francis Boafo ;
Wheeler, Patrick ;
Clare, Jon ;
Watson, Alan .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2013, 28 (06) :2806-2815
[6]  
Ellabban O, 2009, IEEE 13 EUR C POW EL, P1
[7]  
Fereidouni A, 2016, IEEE POWER ENERGY TE
[8]   Single phase three-level neutral-point-clamped quasi-Z-source inverter [J].
Husev, Oleksandr ;
Roncero-Clemente, Carlos ;
Romero-Cadaval, Enrique ;
Vinnikov, Dmitri ;
Stepenko, Serhii .
IET POWER ELECTRONICS, 2015, 8 (01) :1-10
[9]   Current control techniques for three-phase voltage-source PWM converters: A survey [J].
Kazmierkowski, MP ;
Malesani, L .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) :691-703
[10]   A review of single-phase grid-connected inverters for photovoltaic modules [J].
Kjaer, SB ;
Pedersen, JK ;
Blaabjerg, F .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2005, 41 (05) :1292-1306