Evaluation of grip strength measurements after Colles' fracture:: A methodological study

被引:0
作者
Lagerström, C
Nordgren, B
Olerud, C
机构
[1] Uppsala Univ, Dept Rehabil Med, SE-75185 Uppsala, Sweden
[2] Uppsala Univ, Dept Clin Physiol, SE-75185 Uppsala, Sweden
[3] Uppsala Univ, Dept Orthopaed, SE-75185 Uppsala, Sweden
[4] Uppsala Univ, Ctr Caring Sci, SE-75185 Uppsala, Sweden
来源
SCANDINAVIAN JOURNAL OF REHABILITATION MEDICINE | 1999年 / 31卷 / 01期
关键词
Colles' fracture; physiotherapy; isometric grip strength; measurement method; reliability; discriminatory ability;
D O I
暂无
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Maximal isometric grip strength during short and sustained contractions was registered in 28 females and five males with displaced Colles' fracture involving the distal radio-ulnar joint. After reduction the patients were immobilized with plaster cast or with external fixation. The reliability of the measurements of the uninjured side was high and stable over a two-year follow-up period. The between-occasion reliability of the injured side was lower than that of the uninjured side. At each session the intensity of pain was measured. There was a reduction in pain after two years. The discriminatory ability of the measurements was satisfactory. It is suggested that the measurement methods and the present findings may serve as guidance in physiotherapy for these patients, especially if the uninjured side is used as reference.
引用
收藏
页码:49 / 54
页数:6
相关论文
共 18 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]  
[Anonymous], 1987, J Hand Ther, DOI [DOI 10.1016/S0894-1130(87)80009-1, 10.1016/S0894-1130, DOI 10.1016/S0894-1130]
[3]   TIME-DEPENDENT VARIATION IN THE CARDIAC CONDUCTION SYSTEM ASSESSED IN YOUNG HEALTHY-INDIVIDUALS AT WEEKS INTERVAL - IMPLICATIONS FOR CLINICAL-TRIALS [J].
BERGFELDT, L ;
MELANDER, H ;
SCHENCKGUSTAFSSON, K .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 18 (03) :792-800
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]  
EKENSTAM AF, 1986, LAKARTIDNINGEN, V83, P3254
[6]  
FRYKMAN G, 1967, ACTA ORTHOP SCAND S, V108
[7]  
HUSKISSON EC, 1974, LANCET, V2, P1127, DOI 10.1016/S0140-6736(74)90884-8
[8]  
KONGSHOLM J, 1989, CLIN ORTHOP RELAT R, V241, P57
[9]  
Lagerström C, 1999, SCAND J REHABIL MED, V31, P55
[10]  
Lagerstrom C, 1998, SCAND J REHABIL MED, V30, P113