Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study

被引:4
作者
Ding, Qian [1 ,2 ]
Luo, Qiang [3 ]
Tian, Yajing [4 ]
Zhang, Lei [1 ]
Xie, Qiufei [1 ]
Zhou, Yongsheng [1 ]
机构
[1] Peking Univ, Dept Prosthodont, Sch & Hosp Stomatol, 22 South St, Beijing 100081, Peoples R China
[2] Foshan Southern China Inst New Mat, Foshan, Guangdong, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Inst Stomatol, Beijing, Peoples R China
[4] Renmin Univ China, Sch Business, Beijing, Peoples R China
关键词
Dental implant; Single crown; Implant-supported prosthesis; Occlusion; Occlusal force; Marginal bone level; TOOTH WEAR; FORCE; GUIDELINES; PROSTHESES; OVERLOAD; THERAPY; SYSTEMS; SURFACE; SOFT;
D O I
10.1007/s00784-022-04394-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aims to analyze the 5-year occlusal change in posterior implant- supported single crowns and the association between the relative occlusal force ( ROF) and peri-implant bone level. Materials and methods Partially edentulous patients who had received implant-supported single crowns in the posterior region were included. Occlusal examinations with a computerized occlusion analysis system were conducted at 0.5, 3, 6, 12, 24, 36, 48, and 60 months after delivery of the implant-supported single crown. The ROFs of implant- supported single crowns, mesial adjacent teeth, and control natural teeth were recorded. Intraoral periapical radiographs were taken at each follow-up time to evaluate marginal bone level (MBL). Ordinary least square regression was used to analyze the association between ROF and MBL. Results Thirty- seven posterior implant-supported single crowns in 33 participants (23.9 to 70.0 years) were followed up for 0.5 to 60 months [(42.4 +/- 26.0) months]. The ROF of implant-supported single crowns increased from 2 weeks to 3 months (P < 0.01) and increased continuously between all two sequential time points from 6 to 36 months, with significant differences (P < 0.05). Then ROFs of implant-supported single crowns were significantly higher than those of control teeth at 48 and 60 months (P < 0.05). Regression analysis showed that ROF was significantly associated with MBL with a coefficient of 0.008 (P < 0.05). Conclusion The ROFs of posterior implant-supported single crown have significant change during 5 years' follow-up. The association between ROF and MBL has limited clinical significance.
引用
收藏
页码:4217 / 4227
页数:11
相关论文
共 48 条
  • [21] All-ceramic single crowns supported by zirconia implants: 5-year results of a prospective multicenter study
    Spies, Benedikt C.
    Balmer, Marc
    Jung, Ronald E.
    Sailer, Irena
    Vach, Kirstin
    Kohal, Ralf-Joachim
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (05) : 466 - 475
  • [22] Clinical outcomes of single implant supported crowns utilising the titanium base abutment: A 7.5-year prospective cohort study
    Smirani, Rawen
    Chantler, Jennifer G. M.
    Endres, Janina
    Jung, Ronald E.
    Naenni, Nadja
    Strauss, Franz J.
    Thoma, Daniel S.
    JOURNAL OF DENTISTRY, 2024, 149
  • [23] Randomized Controlled Clinical Trial to Compare Posterior Implant-Supported Modified Monolithic Zirconia and Metal-Ceramic Single Crowns: One-Year Results
    Cheng, Chih-Wen
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (01): : 15 - 21
  • [24] Tissue-level versus bone-level single implants in the anterior area rehabilitated with feather-edge crowns on conical implant abutments: An up to 5-year retrospective study
    Canullo, Luigi
    Menini, Maria
    Bagnasco, Francesco
    Di Tullio, Nicola
    Pesce, Paolo
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (05) : 936 - 941
  • [25] Histologic and histomorphometric evaluation of peri-implant bone of immediate or delayed occlusal-loaded non-splinted implants in the posterior mandible - an experimental study in monkeys
    Stokholm, Rie
    Isidor, Flemming
    Nyengaard, Jens R.
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (11) : 1311 - 1318
  • [26] Radiographic changes of trabecular bone density after loading of implant-supported complete dentures: A 3-year prospective study
    Gerhardt, Mauricio N.
    Villarinho, Eduardo A.
    Rockenbach, Maria Ivete B.
    Vigo, Alvaro
    dos Reis, Rodrigo C. P.
    Shinkai, Rosemary S. A.
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2019, 21 (05) : 1041 - 1047
  • [27] Peri-implant defect grafting with autogenous bone or bone graft material in immediate implant placement in molar extraction sites-1-to 3-year results of a prospective randomized study
    Noelken, Robert
    Pausch, Tobias
    Wagner, Wilfried
    Al-Nawas, Bilal
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (11) : 1138 - 1148
  • [28] Evaluation of the Peri-Implant Bone Level around Platform-Switched Dental Implants: A Retrospective 3-Year Radiographic Study
    Pan, Yu Hwa
    Lin, His Kuei
    Lin, Jerry C-Y
    Hsu, Yung-Szu
    Wu, Yi-Fan
    Salamanca, Eisner
    Chang, Wei-Jen
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2019, 16 (14)
  • [29] Clinical Results and Technical Complications of Posterior Implant-Supported Modified Monolithic Zirconia Single Crowns and Short-Span Fixed Dental Prostheses: A 2-Year Pilot Study
    Cheng, Chih-Wen
    Chien, Chia-Hui
    Chen, Chun-Jung
    Papaspyridakos, Panos
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (02): : 108 - 114
  • [30] Treatment of buccal soft tissue dehiscence around single implant: 5-year results from a prospective study
    Roccuzzo, Mario
    Dalmasso, Paola
    Pittoni, Dario
    Roccuzzo, Andrea
    CLINICAL ORAL INVESTIGATIONS, 2019, 23 (04) : 1977 - 1983