Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study

被引:4
|
作者
Ding, Qian [1 ,2 ]
Luo, Qiang [3 ]
Tian, Yajing [4 ]
Zhang, Lei [1 ]
Xie, Qiufei [1 ]
Zhou, Yongsheng [1 ]
机构
[1] Peking Univ, Dept Prosthodont, Sch & Hosp Stomatol, 22 South St, Beijing 100081, Peoples R China
[2] Foshan Southern China Inst New Mat, Foshan, Guangdong, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Inst Stomatol, Beijing, Peoples R China
[4] Renmin Univ China, Sch Business, Beijing, Peoples R China
关键词
Dental implant; Single crown; Implant-supported prosthesis; Occlusion; Occlusal force; Marginal bone level; TOOTH WEAR; FORCE; GUIDELINES; PROSTHESES; OVERLOAD; THERAPY; SYSTEMS; SURFACE; SOFT;
D O I
10.1007/s00784-022-04394-0
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives This study aims to analyze the 5-year occlusal change in posterior implant- supported single crowns and the association between the relative occlusal force ( ROF) and peri-implant bone level. Materials and methods Partially edentulous patients who had received implant-supported single crowns in the posterior region were included. Occlusal examinations with a computerized occlusion analysis system were conducted at 0.5, 3, 6, 12, 24, 36, 48, and 60 months after delivery of the implant-supported single crown. The ROFs of implant- supported single crowns, mesial adjacent teeth, and control natural teeth were recorded. Intraoral periapical radiographs were taken at each follow-up time to evaluate marginal bone level (MBL). Ordinary least square regression was used to analyze the association between ROF and MBL. Results Thirty- seven posterior implant-supported single crowns in 33 participants (23.9 to 70.0 years) were followed up for 0.5 to 60 months [(42.4 +/- 26.0) months]. The ROF of implant-supported single crowns increased from 2 weeks to 3 months (P < 0.01) and increased continuously between all two sequential time points from 6 to 36 months, with significant differences (P < 0.05). Then ROFs of implant-supported single crowns were significantly higher than those of control teeth at 48 and 60 months (P < 0.05). Regression analysis showed that ROF was significantly associated with MBL with a coefficient of 0.008 (P < 0.05). Conclusion The ROFs of posterior implant-supported single crown have significant change during 5 years' follow-up. The association between ROF and MBL has limited clinical significance.
引用
收藏
页码:4217 / 4227
页数:11
相关论文
共 48 条
  • [1] Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study
    Qian Ding
    Qiang Luo
    Yajing Tian
    Lei Zhang
    Qiufei Xie
    Yongsheng Zhou
    Clinical Oral Investigations, 2022, 26 : 4217 - 4227
  • [2] Evaluation of two different occlusal patterns on single posterior implant-supported crowns: A 12-month prospective study of occlusal analysis
    Zhang, Ru
    Hao, Xiaoyu
    Zhang, Kaiyu
    JOURNAL OF PROSTHETIC DENTISTRY, 2024, 132 (06) : 1277 - 1284
  • [3] Association Between Peri-implant Bone Morphology and Marginal Bone Loss: A Retrospective Study on Implant-Supported Mandibular Overdentures
    Ding, Qian
    Zhang, Lei
    Geraets, Wil
    Wu, Wuqing
    Zhou, Yongsheng
    Wismeijer, Daniel
    Xie, Qiufei
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (01) : 147 - 155
  • [4] Occlusal changes on implant-supported single crowns with one year follow-up after loading: A systematic review and meta-analysis
    Mao, Zhen
    Bleiel, Hannah
    Beuer, Florian
    Boese, Mats Wernfried Heinrich
    Soetebeer, Maren
    JOURNAL OF DENTISTRY, 2024, 146
  • [5] Efficacy of Three Interdental Cleaning Methods for Peri-Implant Health Maintenance of Single Implant-Supported Crowns: A Randomised Clinical Trial
    Almoharib, Hani S.
    Alaskar, Mansour H.
    Abuthera, Essam A.
    Alshalhoub, Khalid A.
    Binrokan, Faisal K.
    Alqahtani, Nawaf S.
    Almadhoon, Hossam W.
    ORAL HEALTH & PREVENTIVE DENTISTRY, 2024, 22 (01) : 51 - 56
  • [6] A new classification of peri-implant bone morphology: a radiographic study of patients with lower implant-supported mandibular overdentures
    Zhang, Lei
    Geraets, Wil
    Zhou, Yongsheng
    Wu, Wuqing
    Wismeijer, Daniel
    CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (08) : 905 - 909
  • [7] Occlusal contact and clearance of posterior implant-supported single crowns designed by two different methods: a self-controlled study
    He, Mingzhu
    Pu, Tingting
    Ding, Qian
    Sun, Yao
    Wang, Pengfei
    Sun, Yuchun
    Zhang, Lei
    BMC ORAL HEALTH, 2023, 23 (01)
  • [8] CAD/CAM-fabricated ceramic implant-supported single crowns made from lithium disilicate: Final results of a 5-year prospective cohort study
    Spies, Benedikt Christopher
    Pieralli, Stefano
    Vach, Kirstin
    Kohal, Ralf-Joachim
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2017, 19 (05) : 876 - 883
  • [9] Assessment of Peri-Implant Soft Tissues Conditions around Short and Ultra-Short Implant-Supported Single Crowns: A 3-Year Retrospective Study on Periodontally Healthy Patients and Patients with a History of Periodontal Disease
    Lombardo, Giorgio
    Signoriello, Annarita
    Marincola, Mauro
    Nocini, Pier Francesco
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (24) : 1 - 20
  • [10] Effect of customized abutment taper configuration on bone remodeling and peri-implant tissue around implant-supported single crown: A 3D nonlinear finite element study
    Poovarodom, Pongsakorn
    Rungsiyakull, Chaiy
    Suriyawanakul, Jarupol
    Li, Qing
    Sasaki, Keiichi
    Yoda, Nobuhiro
    Rungsiyakull, Pimduen
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024, 33 (08): : 815 - 823