Effects of indoor pyrotechnic displays on the air quality in the Houston Astrodome

被引:36
作者
Dutcher, DD [1 ]
Perry, KD
Cahill, TA
Copeland, SA
机构
[1] Univ Calif Davis, Crocker Nucl Lab, Determinat Extinct & Long Range Transport Aerosol, Davis, CA 95616 USA
[2] Colorado State Univ, Cooperat Inst Res Atmosphere, Ft Collins, CO 80523 USA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1999年 / 49卷 / 02期
关键词
D O I
10.1080/10473289.1999.10463790
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fine and coarse particulate mass samples were collected during basel,all games with pyrotechnic displays and control games without displays. The average fine and coarse particulate masses were 173 and 141 mu g/m(3), respectively, for the one-hour period immediately following the pyrotechnic displays. The particulate matter generated by the pyrotechnic displays was composed of the following elements (arranged from most to least abundant): K, S, Mg, Ti, Cl, Si, Ca, Al, Sr, V, Zn, Mn, and Pb. Although the average particulate mass concentrations were high during the first hour, the ventilation system reduced the concentrations by up to 41% during the second hour after the display. The fine and coarse particulate fractions had half-lives of 2.0 and 0.9 hours, respectively, while the ventilation system operated at a capacity of one air change every three hours.
引用
收藏
页码:156 / 160
页数:5
相关论文
共 13 条
[1]  
*AM SOC HEAT REFR, 1990, 621989 ASHRAE, P21
[2]   ANALYSIS OF RESPIRABLE FRACTIONS IN ATMOSPHERIC PARTICULATES VIA SEQUENTIAL FILTRATION [J].
CAHILL, TA ;
ASHBAUGH, LL ;
BARONE, JB ;
ELDRED, RA ;
FEENEY, PJ ;
FLOCCHINI, RG ;
GOODART, C ;
SHADOAN, DJ ;
WOLFE, GW .
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1977, 27 (07) :675-678
[3]  
CAHILL TA, 1995, CHEM ANAL SERIES MON, V133, P237
[4]  
Cahill Thomas A., 1990, VISIBILITY FINE PART, P213
[5]   MEASUREMENT OF AEROSOL ABSORPTION-COEFFICIENT FROM TEFLON FILTERS USING INTEGRATING PLATE AND INTEGRATING SPHERE TECHNIQUES [J].
CAMPBELL, D ;
COPELAND, S ;
CAHILL, T .
AEROSOL SCIENCE AND TECHNOLOGY, 1995, 22 (03) :287-292
[6]  
*DEF LOG AG, 1971, ENG DES HDB EXPL SER, P36
[7]  
FLANAGAN S, COMMUNICATION
[8]  
GRANT E, 1997, DALLAS MORNING 0127, pB14
[9]   INTERCOMPARISON OF AMBIENT AEROSOL SAMPLERS USED IN WESTERN VISIBILITY AND AIR-QUALITY STUDIES [J].
MATHAI, CV ;
WATSON, JG ;
ROGERS, CF ;
CHOW, JC ;
TOMBACH, I ;
ZWICKER, JO ;
CAHILL, T ;
FEENEY, P ;
ELDRED, R ;
PITCHFORD, M ;
MUELLER, PK .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1990, 24 (07) :1090-1099
[10]  
MCLAIN JH, 1980, PYROTECHNICS