UHPC-filled duct connections for accelerated bridge construction of RC columns in high seismic zones

被引:144
作者
Tazarv, Mostafa [1 ]
Saiidi, M. Saiid [1 ]
机构
[1] Univ Nevada, Dept Civil & Environm Engn, Reno, NV 89557 USA
关键词
ABC; RC bridge column; UHPC; Duct; Seismic performance; Cyclic test; Analysis; New bond-slip method;
D O I
10.1016/j.engstruct.2015.05.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Substantial attention is being paid to accelerated bridge construction (ABC) in the United States because ABC offers many advantages such as shorter onsite construction time, lower traffic impact, and higher quality structural members. Prefabricated bridge elements and systems are one of the most important ABC components. However, scarcity of seismic performance data for prefabricated element connections has limited the application of ABC in high seismic zones. In this paper, seismic performance of a new column-to-footing connection was experimentally investigated by cyclic testing of a half-scale precast reinforced concrete bridge column connected to the footing incorporating an ultra-high performance concrete (UHPC) filled duct connection. The seismic performance of the test model was comprehensively compared with a reference cast-in-place model. Furthermore, connection performance of another half-scale precast bridge column utilizing this type of connection was presented. The former model was design and tested to specifically evaluate the seismic performance of the column utilizing new column-to-footing connection and the latter column was built with eight different materials to investigate the seismic performance of a low-damage precast column detailing for high seismic regions. Nevertheless, UHPC-filled duct connections were incorporated in the column-to-footing connections of the both test models. The test results showed that the UHPC-filled duct connections were emulative of the conventional connection. An analytical model was developed using a finite element computer program to simulate cyclic response of the column. The model incorporated a new analytical technique to include the effect of bond slip through a modified stress strain relationship for reinforcing steel. The calculated and measured force displacement relationships of the column showed good correlation. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:413 / 422
页数:10
相关论文
共 24 条
[1]  
A.C.I. Committee 239, 2012, 239 ACI COMM
[2]  
American Association State Highway and Transportation Officials, 2014, AASHTO GUID SPEC LRF
[3]  
American Concrete Institute (ACI), 2011, ACI31811
[4]  
[Anonymous], 2006, MAT PROPERTY CHARACT
[5]  
[Anonymous], 2011, 681 NCHRP TRANSP RES, DOI DOI 10.17226/14484
[6]  
[Anonymous], 2013, OPEN SYSTEM EARTHQUA
[7]  
ASTM, 2011, A653A653M11 ASTM
[8]  
ASTM, 2009, A706A706M09B ASTM
[9]  
ASTM S, 2009, A615A615M09B ASTM
[10]  
Caltrans, 2010, SEISM DES CRIT SDC V