Corrosion Resistance of Copper Coatings Deposited by Cold Spraying

被引:21
作者
Winnicki, M. [1 ]
Baszczuk, A. [2 ]
Jasiorski, M. [2 ]
Malachowska, A. [1 ]
机构
[1] Wrocaw Univ Sci & Technol, Dept Mat Sci Strength & Welding Technol, Lukasiewicza 5 Str, PL-50371 Wroclaw, Poland
[2] Wrocaw Univ Sci & Technol, Dept Mech Mat Sci & Engn, Smoluchowskiego 25 Str, PL-50370 Wroclaw, Poland
关键词
copper coatings; cyclic salt spray test; electrical conductivity measurements; Kesternich test; XRD phase analysis; COMPOSITE COATINGS; RESIDUAL-STRESS; WEAR-RESISTANCE; IMPACT BEHAVIOR; LPCS COATINGS; STEEL; MICROSTRUCTURE; PROTECTION; ALUMINUM; METALS;
D O I
10.1007/s11666-017-0646-2
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In the article, a study of corrosion resistance of copper and copper-based cermet (Cu+Al2O3 and Cu+SiC) coatings deposited onto aluminum alloy substrate using the low-pressure cold spraying method is presented. The samples were subjected to two different corrosion tests at room temperature: (1) Kesternich test and (2) a cyclic salt spray test. The selected tests were allowed to simulate service conditions typical for urban, industrial and marine environment. Examination of corroded samples included analysis changes on the coating surface and in the microstructure. The physicochemical tests were carried out using x-ray diffraction to define corrosion products. Moreover, microhardness and electrical conductivity measurements were conducted to estimate mechanical and physical properties of the coatings after corrosion tests. XRD analysis clearly showed that regardless of corrosion conditions, for all samples cuprite (Cu2O) was the main product. However, in the case of Cu+Al2O3 cermet coating, chlorine- and sulfate-containing phases such as Cu2Cl(OH)(3) (paracetamite) and Cu-3(SO4)(OH)(4) (antlerite) were also recorded. This observation gives better understanding of the lowest microstructure changes observed for Cu+Al2O3 coating after the corrosion tests. This is also a justification for the lowest decrease in electrical conductivity registered after the corrosion tests for this coating.
引用
收藏
页码:1935 / 1946
页数:12
相关论文
共 49 条
  • [1] [Anonymous], 2000, 6988 PNEN ISO
  • [2] [Anonymous], 2010, 16701 PNEN ISO
  • [3] Effect of carrier gases on microstructural and electrochemical behavior of cold-sprayed 1100 aluminum coating
    Balani, K
    Laha, T
    Agarwal, A
    Karthikeyan, J
    Munroe, N
    [J]. SURFACE & COATINGS TECHNOLOGY, 2005, 195 (2-3) : 272 - 279
  • [4] Bobic B., 2010, Tribology in industry, V32, P3
  • [5] Investigation of Wear and Corrosion Protection of AlSi20 Coatings Produced by Plasma Spraying and Laser Cladding on AZ31B
    Bobzin, Kirsten
    Kopp, Nils
    Warda, Thomas
    Schulz, Christiane
    Rolink, Gesa
    Weisheit, Andreas
    [J]. JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2013, 22 (2-3) : 207 - 212
  • [6] Bruce D. C., 1994, HDB CORROSION DATA, P20
  • [7] Fatigue behaviour of cold sprayed metals and alloys: critical review
    Cavaliere, P.
    Silvello, A.
    [J]. SURFACE ENGINEERING, 2016, 32 (09) : 631 - 640
  • [8] Mainstreaming cold spray - push for applications
    Champagne, V. K.
    Helfritch, D. J.
    [J]. SURFACE ENGINEERING, 2014, 30 (06) : 396 - 403
  • [9] Di Carloa G., 2017, APPL SURF S IN PRESS
  • [10] Corrosion behaviour of an assembly between an AA1370 cable and a pure copper connector for car manufacturing applications
    Gravina, Rosanne
    Pebere, Nadine
    Laurino, Adrien
    Blanc, Christine
    [J]. CORROSION SCIENCE, 2017, 119 : 79 - 90