Volumetric modulated arc therapy is superior to conventional intensity modulated radiotherapy - a comparison among prostate cancer patients treated in an Australian centre

被引:26
作者
Fogarty, Gerald B. [1 ]
Ng, Diana [1 ]
Liu, Guilin [1 ]
Haydu, Lauren E. [2 ,3 ]
Bhandari, Nastik [1 ]
机构
[1] Mater Hosp, Dept Radiat Oncol, Crows Nest, NSW, Australia
[2] Melanoma Inst Australia, Sydney, NSW, Australia
[3] Univ Sydney, Sydney Med Sch, Sydney, NSW 2006, Australia
来源
RADIATION ONCOLOGY | 2011年 / 6卷
关键词
Intensity-modulated radiotherapy; Volumetric modulated arc therapy; three-dimensional conformal radiotherapy; Australia; health care cost; RADIATION-THERAPY;
D O I
10.1186/1748-717X-6-108
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: Radiotherapy technology is expanding rapidly. Volumetric Modulated Arc Therapy (VMAT) technologies such as RapidArc (R) (RA) may be a more efficient way of delivering intensity-modulated radiotherapy-like (IM) treatments. This study is an audit of the RA experience in an Australian department with a planning and economic comparison to IM. Methods: 30 consecutive prostate cancer patients treated radically with RA were analyzed. Eight RA patients treated definitively were then completely re-planned with 3D conformal radiotherapy (3D); and a conventional sliding window IM technique; and a new RA plan. The acceptable plans and their treatment times were compared and analyzed for any significant difference. Differences in staff costs of treatment were computed and analyzed. Results: Thirty patients had been treated to date with eight being treated definitely to at least 74 Gy, nine post high dose brachytherapy (HDR) to 50.4Gy and 13 post prostatectomy to at least 64Gy. All radiotherapy courses were completed with no breaks. Acute rectal toxicity by the RTOG criteria was acceptable with 22 having no toxicity, seven with grade 1 and one had grade 2. Of the eight re-planned patients, none of the 3D (three-dimensional conformal radiotherapy) plans were acceptable based on local guidelines for dose to organs at risk. There was no statistically significant difference in planning times between IM and RA (p = 0.792). IM had significantly greater MUs per fraction (1813.9 vs 590.2 p < 0.001), total beam time per course (5.2 vs 3.1 hours, p = 0.001) and average treatment staff cost per patient radiotherapy course ($AUD489.91 vs $AUD315.66, p = 0.001). The mean saving in treatment staff cost for RA treatment was $AUD174.25 per patient. Conclusions: 3D was incapable of covering a modern radiotherapy volume for the radical treatment of prostate cancer. These volumes can be treated via conventional IM and RA. RA was significantly more efficient, safe and cost effective than IM. VMAT technologies are a superior way of delivering IM-like treatments.
引用
收藏
页数:5
相关论文
共 9 条
  • [1] Lung cancer patients in Queensland suffer delays in receiving radiation therapy - but not as a result of distance
    Burmeister, B. H.
    Zarate, D. D.
    Burmeister, E. A.
    Harden, H. E.
    Colquist, S. P.
    Cossio, D. L.
    Poulsen, M. G.
    Collins, M.
    Pratt, G. R.
    Walpole, E. T.
    [J]. INTERNAL MEDICINE JOURNAL, 2010, 40 (02) : 126 - 132
  • [2] EVOLUTION AND ACCOMPLISHMENTS OF THE RADIATION-THERAPY ONCOLOGY GROUP
    COX, JD
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (03): : 747 - 754
  • [3] TOLERANCE OF NORMAL TISSUE TO THERAPEUTIC IRRADIATION
    EMAMI, B
    LYMAN, J
    BROWN, A
    COIA, L
    GOITEIN, M
    MUNZENRIDER, JE
    SHANK, B
    SOLIN, LJ
    WESSON, M
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 109 - 122
  • [4] Cost-minimization analysis: Radiation treatment with and without a multi-leaf collimator
    Foroudi, F
    Lapsley, H
    Manderson, C
    Yeghiaian-Alvandi, R
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (05): : 1443 - 1448
  • [5] Intensity-modulated radiation therapy, protons, and the risk of second cancers
    Hall, Eric J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 65 (01): : 1 - 7
  • [6] Kenny Liz, 2004, Australas Radiol, V48, P29, DOI 10.1111/j.1440-1673.2004.01239.x
  • [7] WHOLE-BRAIN RADIOTHERAPY WITH SIMULTANEOUS INTEGRATED BOOST TO MULTIPLE BRAIN METASTASES USING VOLUMETRIC MODULATED ARC THERAPY
    Lagerwaard, Frank J.
    van der Hoorn, Elles A. P.
    Verbakel, Wilko F. A. R.
    Haasbeek, Cornelis J. A.
    Slotman, Ben J.
    Senan, Suresh
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (01): : 253 - 259
  • [8] The effect of intensity-modulated radiotherapy on radiation-induced second malignancies
    Ruben, Jeremy D.
    Davis, Sidney
    Evans, Cherie
    Jones, Phillip
    Gagliardi, Frank
    Haynes, Matthew
    Hunter, Alistair
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (05): : 1530 - 1536
  • [9] NSW HLTH EMPLOYEES M