Electrical impedance tomography: a potential tool for intraoperative imaging of the tongue base

被引:0
作者
Brazey, B. [1 ]
Haddab, Y. [1 ]
Koebel, L. [1 ]
Zemiti, N. [1 ]
机构
[1] Univ Montpellier, CNRS, LIRMM, Montpellier, France
关键词
EIT; electrical impedance tomography; tongue; cancer; surgery; detection; TISSUES; EIT;
D O I
10.1088/1361-6579/ac4a87
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Background. The presence of a tumor in the tongue is a pathology that requires surgical intervention from a certain stage. This type of surgery is difficult to perform because of the limited space available around the base of the tongue for the insertion of surgical tools. During the procedure, the surgeon has to stretch and then fix the tongue firmly in order to optimize the available space and prevent tissue movement. As a result, the preoperative images of the inside of the tongue no longer give a reliable indication of the position and shape of the cancerous tissue due to the deformation of the overall tissue in the area. Thus, new images are needed during the operation, but are very difficult to obtain using conventional techniques due to the presence of surgical tools. Objective. Electrical Impedance Tomography (EIT) is an imaging technique that maps the resistivity or difference of resistivity of biological tissues from electrical signals. The small size of the electrodes makes it a potentially interesting tool to obtain intraoperative images of the inside of the tongue. In this paper, the objective is to study the possibility of using EIT for this purpose is investigated. Main results. A detection method is proposed, including an original configuration of the electrodes, consistent with the anatomical specificities of the tongue. The proposed method is studied in simulation and then a proof of concept is obtained experimentally on a 3D printed test tank filled with saline solution and plant tissue.
引用
收藏
页数:11
相关论文
共 24 条
[1]   Artificial palpation in robotic surgery using haptic feedback [J].
Abiri, Ahmad ;
Juo, Yen-Yi ;
Tao, Anna ;
Askari, Syed J. ;
Pensa, Jake ;
Bisley, James W. ;
Dutson, Erik P. ;
Grundfest, Warren S. .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2019, 33 (04) :1252-1259
[2]   Uses and abuses of EIDORS: an extensible software base for EIT [J].
Adler, A ;
Lionheart, WRB .
PHYSIOLOGICAL MEASUREMENT, 2006, 27 (05) :S25-S42
[3]   Applications of Electrical Impedance Tomography (EIT): A Short Review [J].
Bera, Tushar Kanti .
3RD INTERNATIONAL CONFERENCE ON COMMUNICATION SYSTEMS (ICCS-2017), 2018, 331
[4]   Impedance spectra of tumour tissue in comparison with normal tissue; A possible clinical application for electrical impedance tomography [J].
Blad, B ;
Baldetorp, B .
PHYSIOLOGICAL MEASUREMENT, 1996, 17 :A105-A115
[5]   Electrical impedance tomography [J].
Borcea, L .
INVERSE PROBLEMS, 2002, 18 (06) :R99-R136
[6]   Electrical impedance tomography [J].
Cheney, M ;
Isaacson, D ;
Newell, JC .
SIAM REVIEW, 1999, 41 (01) :85-101
[7]  
Cheney M, 1990, Int J Imaging Syst Technol, V2, P66, DOI 10.1002/ima.1850020203
[8]   The dielectric properties of biological tissues .2. Measurements in the frequency range 10 Hz to 20 GHz [J].
Gabriel, S ;
Lau, RW ;
Gabriel, C .
PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (11) :2251-2269
[9]   Classification of normal and cancerous lung tissues by electrical impendence tomography [J].
Gao, Jianling ;
Yue, Shihong ;
Chen, Jun ;
Wang, Huaxiang .
BIO-MEDICAL MATERIALS AND ENGINEERING, 2014, 24 (06) :2229-2241
[10]   Electrode placement configurations for 3D EIT [J].
Graham, B. M. ;
Adler, A. .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) :S29-S44