Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors

被引:14
作者
Elman, Noel M. [1 ,2 ,3 ]
Ben-Yoav, Hadar [2 ]
Sternheim, Marek [3 ]
Rosen, Rachel [5 ]
Krylov, Slava [4 ]
Shacham-Diamand, Yosi [2 ,3 ]
机构
[1] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[2] Tel Aviv Univ, Fac Engn, Dept Elect Engn Phys Elect, IL-69978 Ramat Aviv, Israel
[3] Tel Aviv Univ, Univ Res Inst NanoSci & NanoTechnol, IL-69978 Ramat Aviv, Israel
[4] Tel Aviv Univ, Fac Engn, Dept Solid Mech Mat & Syst, IL-69978 Ramat Aviv, Israel
[5] Hebrew Univ Jerusalem, Dept Plant Sci, IL-91904 Jerusalem, Israel
关键词
whole-cell sensors; bioluminescence; toxicity; environmental toxicity; water toxicity; MOEMS; MEMS; modulator; optical modulation; lab-on-chip; solid-state shoto-detectors;
D O I
10.1016/j.bios.2008.01.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-D-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02 mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1631 / 1636
页数:6
相关论文
共 42 条
  • [31] Whole-cell luminescence-based flow-through biodetector for toxicity testing
    Philipp Stolper
    Susanne Fabel
    Michael G. Weller
    Dietmar Knopp
    Reinhard Niessner
    Analytical and Bioanalytical Chemistry, 2008, 390 : 1181 - 1187
  • [32] A Smartphone-Based Whole-Cell Array Sensor for Detection of Antibiotics in Milk
    Lu, Mei-Yi
    Kao, Wei-Chen
    Belkin, Shimshon
    Cheng, Ji-Yen
    SENSORS, 2019, 19 (18)
  • [33] Highly Sensitive Whole-Cell Biosensor for Cadmium Detection Based on a Negative Feedback Circuit
    Zhang, Guangbao
    Hu, Shuting
    Jia, Xiaoqiang
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 9
  • [34] Detection of YAP1 and AR-V7 mRNA for Prostate Cancer Prognosis Using an ISFET Lab-On-Chip Platform
    Broomfield, Joseph
    Kalofonou, Melpomeni
    Pataillot-Meakin, Thomas
    Powell, Sue M.
    Fernandes, Rayzel C.
    Moser, Nicolas
    Bevan, Charlotte L.
    Georgiou, Pantelis
    ACS SENSORS, 2022, : 3389 - 3398
  • [35] Detection of Cadmium in Human Biospecimens by a Cadmium-Selective Whole-Cell Biosensor Based on Deoxyviolacein
    Zhang, Juan
    Guo, Yan
    Lin, Yi-ran
    Ma, Bing-chan
    Ge, Xue-ru
    Zhang, Wen-qi
    Zhang, Nai-xing
    Yang, Shu-man
    Hui, Chang-ye
    ACS BIOMATERIALS SCIENCE & ENGINEERING, 2024, 10 (06): : 4046 - 4058
  • [36] Whole-Cell Electrical Activity Under Direct Mechanical Stimulus by AFM Cantilever Using Planar Patch Clamp Chip Approach
    Kalpesh V. Upadhye
    Joseph E. Candiello
    Lance A. Davidson
    Hai Lin
    Cellular and Molecular Bioengineering, 2011, 4 : 270 - 280
  • [37] Whole-Cell Electrical Activity Under Direct Mechanical Stimulus by AFM Cantilever Using Planar Patch Clamp Chip Approach
    Upadhye, Kalpesh V.
    Candiello, Joseph E.
    Davidson, Lance A.
    Lin, Hai
    CELLULAR AND MOLECULAR BIOENGINEERING, 2011, 4 (02) : 270 - 280
  • [38] Probing synergistic toxicity effects on living cells by combination of two different sized nanoparticles by a whole-cell based biochip
    Pandey, Ashish
    Gurbuz, Yasar
    Ozguz, Volkan
    Niazi, Javed H.
    Qureshi, Anjum
    MATERIALS TODAY-PROCEEDINGS, 2017, 4 (08) : 8427 - 8431
  • [39] Assessing the toxicity and the dissolution rate of zinc oxide nanoparticles using a dual-color Escherichia coli whole-cell bioreporter
    Kim, Sunghoon
    Chae, Yooeun
    Kang, Yerin
    An, Youn-Joo
    Yoon, Youngdae
    CHEMOSPHERE, 2016, 163 : 429 - 437
  • [40] Whole-cell biosensors for detection of heavy metal ions in environmental samples based on metallothionein promoters from Tetrahymena thermophila
    Amaro, Francisco
    Turkewitz, Aaron P.
    Martin-Gonzalez, Ana
    Gutierrez, Juan-Carlos
    MICROBIAL BIOTECHNOLOGY, 2011, 4 (04): : 513 - 522