Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors

被引:14
|
作者
Elman, Noel M. [1 ,2 ,3 ]
Ben-Yoav, Hadar [2 ]
Sternheim, Marek [3 ]
Rosen, Rachel [5 ]
Krylov, Slava [4 ]
Shacham-Diamand, Yosi [2 ,3 ]
机构
[1] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[2] Tel Aviv Univ, Fac Engn, Dept Elect Engn Phys Elect, IL-69978 Ramat Aviv, Israel
[3] Tel Aviv Univ, Univ Res Inst NanoSci & NanoTechnol, IL-69978 Ramat Aviv, Israel
[4] Tel Aviv Univ, Fac Engn, Dept Solid Mech Mat & Syst, IL-69978 Ramat Aviv, Israel
[5] Hebrew Univ Jerusalem, Dept Plant Sci, IL-91904 Jerusalem, Israel
关键词
whole-cell sensors; bioluminescence; toxicity; environmental toxicity; water toxicity; MOEMS; MEMS; modulator; optical modulation; lab-on-chip; solid-state shoto-detectors;
D O I
10.1016/j.bios.2008.01.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-D-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02 mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1631 / 1636
页数:6
相关论文
共 42 条
  • [21] A lab-on-chip cell-based biosensor for label-free sensing of water toxicants
    Liu, F.
    Nordin, A. N.
    Li, F.
    Voiculescu, I.
    LAB ON A CHIP, 2014, 14 (07) : 1270 - 1280
  • [22] Integrated device for colorimetric detection of arsenite using polyethylene glycol capped gold nanoparticles—Lab-on-chip
    Nitesh Shalvi
    Kanak Lata Kumar
    Vinod Kumar Verma
    Suman Jain
    Toxicology and Environmental Health Sciences, 2021, 13 : 351 - 362
  • [23] Dielectrophoresis-Based Integrated Lab-on-Chip for Nano and Micro-Particles Manipulation and Capacitive Detection
    Miled, Mohamed Amine
    Sawan, Mohamad
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2012, 6 (02) : 120 - 132
  • [24] Detection of Multiple Breast Cancer ESR1 Mutations on an ISFET Based Lab-on-Chip Platform
    Alexandrou, George
    Moser, Nicolas
    Mantikas, Katerina-Theresa
    Rodriguez-Manzano, Jesus
    Ali, Simak
    Coombes, R. Charles
    Shaw, Jacqui
    Georgiou, Pantelis
    Toumazou, Christopher
    Kalofonou, Melpomeni
    IEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS, 2021, 15 (03) : 380 - 389
  • [25] Towards a Multifunctional Electrochemical Sensing and Niosome Generation Lab-on-Chip Platform Based on a Plug-and-Play Concept
    Kara, Adnane
    Rouillard, Camille
    Mathault, Jessy
    Boisvert, Martin
    Tessier, Frederic
    Landari, Hamza
    Melki, Imene
    Laprise-Pelletier, Myriam
    Boisselier, Elodie
    Fortin, Marc-Andre
    Boilard, Eric
    Greener, Jesse
    Miled, Amine
    SENSORS, 2016, 16 (06):
  • [26] Rapid detection of Klebsiella pneumoniae using an auto-calibrated ISFET-array Lab-on-Chip platform
    Rodriguez-Manzano, Jesus
    Miscourides, Nicholas
    Malpartida-Cardenas, Kenny
    Pennisi, Ivana
    Moser, Nicolas
    Holmes, Alison
    Georgiou, Pantelis
    2019 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS 2019), 2019,
  • [27] Mathematical model of whole cell based bio-chip: An electrochemical biosensor for water toxicity detection
    Popovtzer, Rachela
    Natan, Amir
    Shacham-Diamand, Yosi
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2007, 602 (01): : 17 - 23
  • [28] Liquid crystal-based biosensors as lab-on-chip tools: Promising for future on-site detection test kits
    Khoshbin, Zahra
    Abnous, Khalil
    Taghdisi, Seyed Mohammad
    Verdian, Asma
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2021, 142
  • [29] Quantitative and rapid Plasmodium falciparum malaria diagnosis and artemisinin-resistance detection using a CMOS Lab-on-Chip platform
    Malpartida-Cardenas, Kenny
    Miscourides, Nicholas
    Rodriguez-Manzano, Jesus
    Yu, Ling-Shan
    Moser, Nicolas
    Baum, Jake
    Georgiou, Pantelis
    BIOSENSORS & BIOELECTRONICS, 2019, 145
  • [30] Whole-cell luminescence-based flow-through biodetector for toxicity testing
    Philipp Stolper
    Susanne Fabel
    Michael G. Weller
    Dietmar Knopp
    Reinhard Niessner
    Analytical and Bioanalytical Chemistry, 2008, 390 : 1181 - 1187