Towards toxicity detection using a lab-on-chip based on the integration of MOEMS and whole-cell sensors

被引:14
|
作者
Elman, Noel M. [1 ,2 ,3 ]
Ben-Yoav, Hadar [2 ]
Sternheim, Marek [3 ]
Rosen, Rachel [5 ]
Krylov, Slava [4 ]
Shacham-Diamand, Yosi [2 ,3 ]
机构
[1] MIT, Dept Mat Sci & Engn, Cambridge, MA 02139 USA
[2] Tel Aviv Univ, Fac Engn, Dept Elect Engn Phys Elect, IL-69978 Ramat Aviv, Israel
[3] Tel Aviv Univ, Univ Res Inst NanoSci & NanoTechnol, IL-69978 Ramat Aviv, Israel
[4] Tel Aviv Univ, Fac Engn, Dept Solid Mech Mat & Syst, IL-69978 Ramat Aviv, Israel
[5] Hebrew Univ Jerusalem, Dept Plant Sci, IL-91904 Jerusalem, Israel
关键词
whole-cell sensors; bioluminescence; toxicity; environmental toxicity; water toxicity; MOEMS; MEMS; modulator; optical modulation; lab-on-chip; solid-state shoto-detectors;
D O I
10.1016/j.bios.2008.01.028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A lab-on-chip consisting of a unique integration of whole-cell sensors, a MOEMS (Micro-Opto-Electro-Mechanical-System) modulator, and solid-state photo-detectors was implemented for the first time. Whole-cell sensors were genetically engineered to express a bioluminescent reporter (lux) as a function of the lac promoter. The MOEMS modulator was designed to overcome the inherent low frequency noise of solid-state photo-detectors by means of a previously reported modulation technique, named IHOS (Integrated Heterodyne Optical System). The bio-reporter signals were modulated prior to photo-detection, increasing the SNR of solid-state photo-detectors at least by three orders of magnitude. Experiments were performed using isopropyl-beta-D-thiogalactopyranoside (IPTG) as a preliminary step towards testing environmental toxicity. The inducer was used to trigger the expression response of the whole-cell sensors testing the sensitivity of the lab-on-chip. Low intensity bio-reporter optical signals were measured after the whole-cell sensors were exposed to IPTG concentrations of 0.1, 0.05, and 0.02 mM. The experimental results reveal the potential of this technology for future implementation as an inexpensive massive method for rapid environmental toxicity detection. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1631 / 1636
页数:6
相关论文
共 42 条
  • [1] Whole cell luminescence biosensor based lab-on-chip integrated system for water toxicity analysis
    Rabner, Arthur
    Belkin, Shimshon
    Rozen, Rachel
    Shacham, Yosi
    MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS IV, 2006, 6112
  • [2] LIGHT EMITTING DEVICES AND INTEGRATED ELECTROCHEMICAL SENSORS ON LAB-ON-CHIP FOR TOXICITY BIOASSAYS BASED ON ALGAL PHYSIOLOGY
    Tsopela, A.
    Laborde, A.
    Salvagnac, L.
    Seguy, I.
    Izquierdo, R.
    Juneau, P.
    Temple-Boyer, P.
    Launay, J.
    2015 TRANSDUCERS - 2015 18TH INTERNATIONAL CONFERENCE ON SOLID-STATE SENSORS, ACTUATORS AND MICROSYSTEMS (TRANSDUCERS), 2015, : 1621 - 1624
  • [3] Monolithic Wafer Scale Integration of Silicon Nanoribbon Sensors with CMOS for Lab-on-Chip Application
    Jayakumar, Ganesh
    Hellstrom, Per-Erik
    Ostling, Mikael
    MICROMACHINES, 2018, 9 (11):
  • [4] Biomolecular Monitoring Tool Based on Lab-on-Chip for Virus Detection
    Costantini, Francesca
    Lovecchio, Nicola
    Nandimandalam, Manasa
    Manglli, Ariana
    Faggioli, Francesco
    Biasin, Mara
    Manetti, Cesare
    Roversi, Pio Federico
    Nascetti, Augusto
    de Cesare, Giampiero
    Caputo, Domenico
    BIOSENSORS-BASEL, 2023, 13 (05):
  • [5] Simple lab-on-chip approach with time-based detection
    Grudpan, K.
    Lapanantnoppakhun, S.
    Hartwell, S. Kradtap
    Watla-iad, K.
    Wongwilai, W.
    Siriangkhawut, W.
    Jangbai, W.
    Kumutanat, W.
    Nuntaboon, P.
    Tontrong, S.
    TALANTA, 2009, 79 (04) : 990 - 994
  • [6] Towards High Sensitive Label Free DNA Detection in Lab-on-Chip Systems
    Hoffmann, W.
    Muehberger, H.
    Hwang, W.
    Demattio, H.
    Guber, A.
    Saile, V.
    PROCEEDINGS OF THE THIRD INTERNATIONAL CONFERENCE ON SENSING TECHNOLOGY, 2008, : 615 - +
  • [7] Assay of chondroitin sulfate using time-based detection in a simple lab-on-chip
    S. Kradtap Hartwell
    W. Sripaoraya
    K. Grudpan
    Journal of Analytical Chemistry, 2011, 66 : 135 - 138
  • [8] Assay of chondroitin sulfate using time-based detection in a simple lab-on-chip
    Hartwell, S. Kradtap
    Sripaoraya, W.
    Grudpan, K.
    JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 66 (02) : 135 - 138
  • [9] Detection of pathogens in foods using microfluidic "lab-on-chip": A mini review
    Lonchamps, Pierre-Luc
    He, Yihan
    Wang, Kaidi
    Lu, Xiaonan
    JOURNAL OF AGRICULTURE AND FOOD RESEARCH, 2022, 10
  • [10] Enhancement in the limit of detection of lab-on-chip microfluidic devices using functional nanomaterials
    Vaishampayan, Vijay
    Kapoor, Ashish
    Gumfekar, Sarang P.
    CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 2023, 101 (09) : 5208 - 5221