Improved quantitative myocardial T2 mapping: Impact of the fitting model

被引:60
作者
Akcakaya, Mehmet [1 ,2 ]
Basha, Tamer A. [1 ,2 ]
Weingaertner, Sebastian [1 ,2 ,3 ]
Roujol, Sebastien [1 ,2 ]
Berg, Sophie [1 ,2 ]
Nezafat, Reza [1 ,2 ]
机构
[1] Beth Israel Deaconess Med Ctr, Dept Med, Div Cardiovasc, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Heidelberg Univ, Univ Med Ctr Mannheim, Comp Assisted Clin Med, Mannheim, Germany
关键词
quantitative myocardial tissue characterization; myocardial T-2 mapping; three-parameter fit; myocardial inflammation; CARDIOVASCULAR MAGNETIC-RESONANCE; ACUTE CORONARY SYNDROME; TRANSPLANT REJECTION; T2; QUANTIFICATION; RELAXATION-TIMES; EDEMA; INFARCTION; HEART; SEQUENCES; CONTRAST;
D O I
10.1002/mrm.25377
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop an improved T-2 prepared (T(2)prep) balanced steady-state free-precession (bSSFP) sequence and signal relaxation curve fitting method for myocardial T-2 mapping. MethodsMyocardial T-2 mapping is commonly performed by acquisition of multiple T(2)prep bSSFP images and estimating the voxel-wise T-2 values using a two-parameter fit for relaxation. However, a two-parameter fit model does not take into account the effect of imaging pulses in a bSSFP sequence or other imperfections in T(2)prep RF pulses, which may decrease the robustness of T-2 mapping. Therefore, we propose a novel T-2 mapping sequence that incorporates an additional image acquired with saturation preparation, simulating a very long T(2)prep echo time. This enables the robust estimation of T-2 maps using a 3-parameter fit model, which captures the effect of imaging pulses and other imperfections. Phantom imaging is performed to compare the T-2 maps generated using the proposed 3-parameter model with the conventional two-parameter model, as well as a spin echo reference. In vivo imaging is performed on eight healthy subjects to compare the different fitting models. ResultsPhantom and in vivo data show that the T-2 values generated by the proposed 3-parameter model fitting do not change with different choices of the T(2)prep echo times, and are not statistically different than the reference values for the phantom (P=0.10 with three T(2)prep echoes). The two-parameter model exhibits dependence on the choice of T(2)prep echo times and are significantly different than the reference values (P=0.01 with three T(2)prep echoes). ConclusionThe proposed imaging sequence in combination with a three-parameter model allows accurate measurement of myocardial T-2 values, which is independent of number and duration of T(2)prep echo times. Magn Reson Med 74:93-105, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:93 / 105
页数:13
相关论文
共 37 条
  • [1] Diagnostic performance of cardiovascular magnetic resonance in patients with suspected acute myocarditis -: Comparison of different approaches
    Abdel-Aty, H
    Boyé, P
    Zagrosek, A
    Wassmuth, R
    Kumar, A
    Messroghli, D
    Bock, P
    Dietz, R
    Friedrich, MG
    Schulz-Menger, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (11) : 1815 - 1822
  • [2] Delayed enhancement and T2-weighted cardiovascular magnetic resonance imaging differentiate acute from chronic myocardial infarction
    Abdel-Aty, H
    Zagrosek, A
    Schulz-Menger, J
    Taylor, AJ
    Messroghli, D
    Kumar, A
    Gross, M
    Dietz, R
    Friedrich, MG
    [J]. CIRCULATION, 2004, 109 (20) : 2411 - 2416
  • [3] T2-weighted cardiovascular magnetic resonance imaging
    Abdel-Aty, Hassan
    Simonetti, Orlando
    Friedrich, Matthias G.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2007, 26 (03) : 452 - 459
  • [4] Myocardial edema is a feature of Tako-Tsubo cardiomyopathy and is related to the severity of systolic dysfunction: Insights from T2-weighted cardiovascular magnetic resonance
    Abdel-Aty, Hassan
    Cocker, Myra
    Friedrich, Matthias G.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2009, 132 (02) : 291 - 293
  • [5] On the Selection of Sampling Points for Myocardial T1 Mapping
    Akcakaya, Mehmet
    Weingaertner, Sebastian
    Roujol, Sebastien
    Nezafat, Reza
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2015, 73 (05) : 1741 - 1753
  • [6] [Anonymous], P 18 ANN M ISMRM STO
  • [7] Using magnetic resonance imaging to characterize recent myocardial injury - Utility in acute coronary syndrome and other clinical scenarios
    Arai, Andrew E.
    [J]. CIRCULATION, 2008, 118 (08) : 795 - 796
  • [8] Interleaved T1 and T2 Relaxation Time Mapping for Cardiac Applications
    Blume, Ulrike
    Lockie, Timothy
    Stehning, Christian
    Sinclair, Stephen
    Uribe, Sergio
    Razavi, Reza
    Schaeffter, Tobias
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 29 (02) : 480 - 487
  • [9] BOTTOMLEY PA, 1984, MED PHYS, V11, P425, DOI 10.1118/1.595535
  • [10] CORONARY ANGIOGRAPHY WITH MAGNETIZATION-PREPARED T-2 CONTRAST
    BRITTAIN, JH
    HU, BS
    WRIGHT, GA
    MEYER, CH
    MACOVSKI, A
    NISHIMURA, DG
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) : 689 - 696