Histological examination of the biocompatibility of polyethylene glycol terephthalate in a rat in vivo bone model

被引:0
|
作者
Ceyhan, Taskin [1 ]
Guelcubuk, Ahmet [2 ]
Sayrak, Hakan [3 ]
Karaca, Cetin [4 ]
机构
[1] Ozel Cevre Hastanesi, Ortoped Travmatol Bolumu, TR-34394 Istanbul, Turkey
[2] Istanbul Univ Vet, Fak Patol Anabilim Dali, Istanbul, Turkey
[3] Istanbul Pasabahce Devlet Hastanesi Patol Klin, Istanbul, Turkey
[4] Istanbul Univ Cerrahpasa, Tip Fak Deney Hayvanlari Uretim Arastirma Merkezi, Istanbul, Turkey
来源
EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY | 2007年 / 18卷 / 01期
关键词
biocompatible materials; osteogenesis; polyethylene terephthalates; prostheses and implants; rats;
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objectives: The purpose of the study was to examine histocompatibility of polyethylene terephthalate (PET) fibers with bone tissue and its usability as a bone substitute. Materials and methods: Twenty male Wistar rats were divided into four groups equal in number. The proximal ends of the right hind tibia bones were drilled and PET thread ball fibers (PET, Advansa SaSA) were placed into 0.5 cm(2) holes. The left hind tibias (controls) were subjected to the same drilling procedure but were left untreated for natural healing. The four groups of rats were sacrificed after 2, 4, 6, and 8 weeks, respectively, and the hind tibias were removed for histologic examination. Results: There was an increased number of bone tissue cells surrounding PET fibers, which were similar to those of control specimens with respect to number and morphological features. Formation of fibroblasts and osteoblasts was at the highest level within the first two weeks. Giant cell formation was observed in all PET groups, but was larger in number in two- and eight-week groups. At 4, 6, and 8 weeks, osteoid tissue produced by osteoblasts was seen in some areas around the fibers without any formation of fibrous tissue. No signs of biodegradation of PET fibers were observed under light microscopy. Conclusion: The presence of osteoblasts, osteocytes, osteoids, and calcified new bone tissue around PET fibers suggests that PET has osteoconductive properties. In order to be used as a bone substitute, further studies are required on its biochemical and interaction properties.
引用
收藏
页码:33 / 38
页数:6
相关论文
共 50 条
  • [1] Histological evaluation of bone in vivo rat model of polyethylene glycol terephthalate biocompatibility (vol 18, pg 33, 2007)
    Ceyhan, T.
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2009, 20 (03): : 178 - 178
  • [2] The Potential of Polyethylene Terephthalate Glycol as Biomaterial for Bone Tissue Engineering
    Hassan, Mohamed H.
    Omar, Abdalla M.
    Daskalakis, Evangelos
    Hou, Yanhao
    Huang, Boyang
    Strashnov, Ilya
    Grieve, Bruce D.
    Bartolo, Paulo
    POLYMERS, 2020, 12 (12) : 1 - 12
  • [3] Enhance the biocompatibility and osseointegration of polyethylene terephthalate ligament by plasma spraying with hydroxyapatite in vitro and in vivo
    Wang, Siheng
    Ge, Yunshen
    Ai, Chengchong
    Jiang, Jia
    Cai, Jiangyu
    Sheng, Dandan
    Wan, Fang
    Liu, Xingwang
    Hao, Yuefeng
    Chen, Jun
    Chen, Shiyi
    INTERNATIONAL JOURNAL OF NANOMEDICINE, 2018, 13 : 3609 - 3623
  • [4] Histological examinations of the in vivo biocompatibility of oxycellulose implanted into rat skeletal muscle
    Kunert-Keil, Christiane
    Narath, Isabel
    Hadzik, Jakub
    Gedrange, Tomasz
    Gredes, Tomasz
    Dominiak, Marzena
    ADVANCES IN CLINICAL AND EXPERIMENTAL MEDICINE, 2019, 28 (05): : 593 - 599
  • [5] In vivo and in vitro responses to poly(ethylene terephthalate-co-diethylene glycol terephthalate) and polyethylene oxide blends
    Barcellos, IO
    Carobrez, SG
    Pires, ATN
    Alvarez-Silva, M
    BIOMATERIALS, 1998, 19 (22) : 2075 - 2082
  • [6] The biocompatibility of polyethylene terephthalate PET (Trevira(R) hochfest). An in vivo study on sheep stifle joints
    Seitz, H
    Marlovits, S
    Schwendenwein, I
    Vecsei, V
    Losert, U
    BIOMEDIZINISCHE TECHNIK, 1996, 41 (06): : 178 - 182
  • [7] Morphological Analysis of Biocompatibility of Autologous Bone Marrow Mononuclear Cells with Synthetic Polyethylene Terephthalate Scaffold
    Gilevich, I. V.
    Polyakov, I. S.
    Porkhanov, V. A.
    Chekhonin, V. P.
    BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2017, 163 (03) : 400 - 404
  • [8] Morphological Analysis of Biocompatibility of Autologous Bone Marrow Mononuclear Cells with Synthetic Polyethylene Terephthalate Scaffold
    I. V. Gilevich
    I. S. Polyakov
    V. A. Porkhanov
    V. P. Chekhonin
    Bulletin of Experimental Biology and Medicine, 2017, 163 : 400 - 404
  • [9] Biocompatibility and Degradation Behavior of Molybdenum in an In Vivo Rat Model
    Schauer, Antje
    Redlich, Christian
    Scheibler, Jakob
    Poehle, Georg
    Barthel, Peggy
    Maennel, Anita
    Adams, Volker
    Weissgaerber, Thomas
    Linke, Axel
    Quadbeck, Peter
    MATERIALS, 2021, 14 (24)
  • [10] In vivo biocompatibility evaluation of in situ-forming polyethylene glycol-collagen hydrogels in corneal defects
    Chun, Yoon Hong
    Park, Sun-Kyoung
    Kim, Eun Jeong
    Lee, Hyun Jong
    Kim, Hyewon
    Koh, Won-Gun
    Cunha, Gabriella Fernandes
    Myung, David
    Na, Kyung-Sun
    SCIENTIFIC REPORTS, 2021, 11 (01)