School building experimental characterization in Mediterranean climate regarding comfort, indoor air quality and energy consumption

被引:37
作者
Barbosa, F. C. [1 ]
de Freitas, V. P. [1 ]
Almeida, M. [2 ]
机构
[1] Univ Porto, Fac Engn, Construct LFC, R Dr Roberto Frias, P-4200465 Porto, Portugal
[2] Univ Minho, Sch Engn, Dept Civil Engn, CTAC, Campus Azurem, P-4804533 Guimaraes, Portugal
关键词
School buildings; Thermal comfort; Indoor air quality; Energy consumption; Prototype; Experimental characterization; PERFORMANCE; CLASSROOMS; VENTILATION; ENVIRONMENT; STRATEGIES; EFFICIENCY;
D O I
10.1016/j.enbuild.2020.109782
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Public school buildings represent an important share of public buildings in Europe, some of them built several decades ago. In Portugal, there are about 5800 public schools, many of them in free-running conditions, with significant thermal discomfort and without any heating strategy due to economic restrictions. This work studies the Portuguese Brandao school model (from the '70 s), which comprises about 100 non-refurbished basic schools. This paper suggests the passive refurbishment of these public schools with some affordable interventions, regarding the climate features and the reduced capacity to support the operating costs. A prototype classroom was prepared in a Brandao school, in Porto. The in situ experimental campaign consisted of temperature, relative humidity, CO2 concentration and energy consumption measurements. The prototype construction included the improvement of the envelope and of the technical systems. The main goals of this work are: (1) the comparison of the prototype in-service thermal performance in pre-existing conditions and the improvement after the refurbishment in free-running conditions or with some intermittent heating strategies; (2) the establishment of discomfort indexes for the assessment of the discomfort for Mediterranean temperate climate; (3) the quantification of the energy consumption vs discomfort regarding the passive refurbishment strategy and the intermittent heating strategies. When comparing the before and after refurbishment results, the mean daily discomfort indicator has decreased from 34.7 degrees C.hour to 25.2 degrees C.hour in free-running conditions and after the refurbishment has decreased from 25.2 degrees C.hour to 11.9 degrees C.hour for 3 heating hours strategy and to 2.5 degrees C.hour for 10 heating hours strategy. There was an expected increase of CO2 inside the classroom for the corresponding months before and after refurbishment, although the mean CO2 was below the required 1500 ppm. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:17
相关论文
共 52 条
[1]  
Agencia Estatal de Meteorologia Ministerio de Medio Ambiente y Medio Rural y Marino Instituto de Meteorologia de Portugal Iberian Climate Atlas, 2011, AIR TEMP PREC 1971 2
[2]  
Alegre A., 2010, ESCOLAS TECNICAS SEC
[3]   Envelope retrofitting strategies for public school buildings in Jordan [J].
Ali, Hikmat ;
Hashlamun, Rifqa .
JOURNAL OF BUILDING ENGINEERING, 2019, 25
[4]  
Almeida R., 2011, Avaliacao do desempenho higrotermico do parque escolar reabilitado
[5]  
Almeida R.M., 2015, School Buildings Rehabilitation: Indoor Environmental Quality and Enclosure Optimization
[6]  
Almeida R.M. S.F., 2014, J PERFORM CONSTR FAC
[7]   Indoor environmental quality of classrooms in Southern European climate [J].
Almeida, Ricardo M. S. F. ;
de Freitas, Vasco Peixoto .
ENERGY AND BUILDINGS, 2014, 81 :127-140
[8]  
[Anonymous], 2011, Proceedings of the 9th ACM Conference on Embedded Networked Sensor Systems, DOI DOI 10.1145/2070942.2070966
[9]  
[Anonymous], 2005, Ergonomics of the thermal environment _ Analytical determination and interpretation of thermal comfort using calculation of the PMV and PPD indices and local thermal comfort criteria, DOI DOI 10.1016/J.SOILDYN.2004.11.005
[10]  
[Anonymous], 2011, EPE P N 2011 31 A3 4