Fracture resistance and 2-body wear of 3-dimensional-printed occlusal devices

被引:62
作者
Lutz, Anna-Maria [1 ]
Hampe, Ruediger [2 ]
Roos, Malgorzata [3 ]
Luemkemann, Nina [2 ]
Eichberger, Marlis [1 ]
Stawarczyk, Bogna [2 ]
机构
[1] Ludwig Maximilians Univ Munchen, Dept Prosthet Dent, Dent Mat Unit, Munich, Germany
[2] Ludwig Maximilians Univ Munchen, Dept Prosthodont, Dent Mat Unit, Munich, Germany
[3] Univ Zurich, Dept Biostat, Epidemiol Biostat & Prevent Inst, Zurich, Switzerland
关键词
ORAL APPLIANCES; BITE FORCE; SPLINT; TECHNOLOGY;
D O I
10.1016/j.prosdent.2018.04.007
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Polymeric material for 3-dimensional printing can be used to fabricate occlusal devices. However, information about fracture resistance and wear is scarce. Purpose.The purpose of this in vitro study was to investigate the fracture resistance and 2-body wear of 3-dimensional-printed (3DP) (FotoDent splint; Dreve Dentamid GmbH), milled polymethylmethacrylate (CAM) (Temp Basic; Transpa 95H16, Zirkonzahn GmbH), and conventionally fabricated polymethylmethacrylate (CAST) (Castdon; Dreve Dentamid GmbH) occlusal devices. Material and methods. A total of 96 occlusal devices were prepared according to the 3 different manufacturing techniques 3DP, CAM, and CAST (n=32). For each manufacturing technique, specimens were further divided into initial fracture resistance tests (n=16) and artificial aging in the mastication simulator (50 N, 37 degrees C) with 2-body wear followed by fracture resistance tests (n=16). The fracture resistance was determined using a universal testing machine (1 mm/min). The wear was measured after 20 000 and 120 000 mastication cycles with the replica technique, mapped with a laser scanner, and quantified in R software. Data were analyzed using a 2-way ANOVA followed by a 1-way ANOVA with Scheffe or Games-Howell post hoc tests, repeated measures ANOVA with corrected Greenhouse-Geisser P values, and the Levene, Mann-Whitney, and paired t tests (alpha=.05). Results. CAM presented higher initial fracture resistance than 3DP or CAST (P<.001). After mastication simulation, CAM followed by 3DP showed higher fracture resistance than CAST (P<.001). Mastication simulation decreased the fracture resistance for CAM and CAST (P<.001) but not for 3DP (P=.78). Three-dimensional-printed occlusal devices showed the highest material volume loss, followed by CAM and the lowest in CAST (P<.001). Conclusions. Three-dimensional-printed occlusal devices showed the highest material volume loss, followed by CAM and the lowest in CAST (P<.001). Three-dimensional-printed occlusal devices showed lower wear resistance and lower fracture resistance than those milled or conventionally fabricated. Therefore, only short-term application in the mouth is recommended. Further developments of occlusal device material for 3-dimensional printing are necessary.
引用
收藏
页码:166 / 172
页数:7
相关论文
共 35 条
  • [1] [Anonymous], 1986, GOOGLE PATENTS
  • [2] SIMPLIFIED TECHNIQUE FOR FABRICATION OF NIGHT GUARDS
    BECKER, CM
    KAISER, DA
    LEMM, RB
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1974, 32 (05) : 582 - 589
  • [3] Dimensional stability of occlusal splints
    Bohnenkamp, DM
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 75 (03) : 262 - 268
  • [4] In vitro wear of various orthotic device materials
    Casey, J
    Dunn, WJ
    Wright, E
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2003, 90 (05) : 498 - 502
  • [5] Influence of layer thickness on mechanical properties in stereolithography
    Chockalingam, K.
    Jawahar, N.
    Chandrasekhar, U.
    [J]. RAPID PROTOTYPING JOURNAL, 2006, 12 (02) : 106 - 113
  • [6] Oral splints: The crutches for temporomandibular disorders and bruxism?
    Dao, TTT
    Lavigne, GJ
    [J]. CRITICAL REVIEWS IN ORAL BIOLOGY & MEDICINE, 1998, 9 (03) : 345 - 361
  • [7] Three-Dimensional Plotting and Printing of an Implant Drilling Guide: Simplifying Guided Implant Surgery
    Fluegge, Tabea Viktoria
    Nelson, Katja
    Schmelzeisen, Rainer
    Metzger, Marc Christian
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 71 (08) : 1340 - 1346
  • [8] TWO-BODY WEAR OF ARTIFICIAL ACRYLIC AND COMPOSITE RESIN TEETH IN RELATION TO ANTAGONIST MATERIAL
    Hahnel, Sebastian
    Behr, Michael
    Handel, Gerhard
    Rosentritt, Martin
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2009, 101 (04) : 269 - 278
  • [9] How to qualify and validate wear simulation devices and methods
    Heintze, S. D.
    [J]. DENTAL MATERIALS, 2006, 22 (08) : 712 - 734
  • [10] Polishability and wear resistance of splint material for oral appliances produced with conventional, subtractive, and additive manufacturing
    Huettig, Fabian
    Kustermann, Achim
    Kuscu, Ebru
    Geis-Gerstorfer, Juergen
    Spintzyk, Sebastian
    [J]. JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2017, 75 : 175 - 179