Highly Porous Titanium Acetabular Components in Primary and Revision Total Hip Arthroplasty: A Systematic Review

被引:34
作者
Malahias, Michael-Alexander [1 ]
Kostretzis, Lazaros [1 ]
Greenberg, Alex [1 ]
Nikolaou, Vasileios S. [2 ]
Atrey, Amit [3 ,4 ]
Sculco, Peter K. [1 ]
机构
[1] Hosp Special Surg, Stavros Niarchos Fdn Complex, Joint Reconstruct Ctr, 535 E 70th St, New York, NY 10021 USA
[2] Natl & Kapodistrian Univ Athens, Sch Med, Orthopaed Dept 2, Athens, Greece
[3] St Michaels Hosp, Div Orthopaed, Toronto, ON, Canada
[4] Univ Toronto, Dept Surg, Toronto, ON, Canada
关键词
total hip replacement; revision arthroplasty; trabecular titanium acetabular; tritanium; systematic review; OUTCOMES; SURGERY; CUPS;
D O I
10.1016/j.arth.2020.01.052
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: A number of papers have been published reporting on the clinical performance of highly porous coated titanium acetabular cups in primary and revision total hip arthroplasty (THA). However, no systematic review of the literature has been published to date. Methods: The US National Library of Medicine (PubMed/MEDLINE), Embase, and the Cochrane Database of Systematic Reviews were queried for publications utilizing the following keywords: "tritanium" OR "highly-porous" AND "titanium" OR "acetabular" AND "trabecular" AND "titanium". Results: Overall, 16 studies were included in this review (11,366 cases; 60% females, 2-7 years mean follow-up). The overall survival rate of highly porous titanium acetabular components in primary cases was 99.3% (10,811 of 10,886 cases), whereas the rate of aseptic loosening was 0.1%. The overall survival rate of the highly porous titanium acetabular components in revision THA cases was 93.5% (449 of 480 cases), whereas the rate of aseptic loosening was 2.1%. Conclusion: There was moderate quality evidence to show that the use of highly porous titanium acetabular components in primary and revision THA cases is associated with satisfactory clinical outcomes in the short- and medium-term, without showing any evidence of cup migration or radiolucency. Taking into consideration that there is no evidence yet regarding the long-term survivorship of these components, we feel that further research of higher quality is required to generate more evidence-based conclusions regarding the longevity of highly porous titanium acetabular implants compared with conventional titanium counterparts. (C) 2020 Elsevier Inc. All rights reserved.
引用
收藏
页码:1737 / 1749
页数:13
相关论文
共 26 条
  • [1] Systematic review on outcomes of acetabular revisions with highly-porous metals
    Banerjee, Samik
    Issa, Kimona
    Kapadia, Bhaveen H.
    Pivec, Robert
    Khanuja, Harpal S.
    Mont, Michael A.
    [J]. INTERNATIONAL ORTHOPAEDICS, 2014, 38 (04) : 689 - 702
  • [2] Short to Midterm Follow-Up of the Tritanium Primary Acetabular Component: A Cause for Concern
    Carli, Alberto V.
    Warth, Lucian C.
    Bentley, Karen L. de Mesy
    Nestor, Bryan J.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (02) : 463 - 469
  • [3] Highly porous titanium cup in cementless total hip arthroplasty: registry results at eight years
    Castagnini, Francesco
    Bordini, Barbara
    Stea, Susanna
    Calderoni, Pierina Paola
    Masetti, Claudio
    Busanelli, Luca
    [J]. INTERNATIONAL ORTHOPAEDICS, 2019, 43 (08) : 1815 - 1821
  • [4] 3D Printed Acetabular Cups for Total Hip Arthroplasty: A Review Article
    Dall'Ava, Lorenzo
    Hothi, Harry
    Di Laura, Anna
    Henckel, Johann
    Hart, Alister
    [J]. METALS, 2019, 9 (07)
  • [5] Trabecular Titanium acetabular cups in hip revision surgery: mid-term clinical and radiological outcomes
    De Meo, Federico
    Cacciola, Giorgio
    Bellotti, Vittorio
    Bruschetta, Antongiolio
    Cavaliere, Pietro
    [J]. HIP INTERNATIONAL, 2018, 28 : 61 - 65
  • [6] Midterm Outcomes of Revision Total Hip Arthroplasty With the Use of a Multihole Highly-Porous Titanium Shell
    Delanois, Ronald E.
    Gwam, Chukwuweike U.
    Mohamed, Nequesha
    Khlopas, Anton
    Chughtai, Morad
    Malkani, Arthur L.
    Mont, Michael A.
    [J]. JOURNAL OF ARTHROPLASTY, 2017, 32 (09) : 2806 - 2809
  • [7] DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
  • [8] Management of severe bone loss in acetabular revision using a trabecular metal shell
    Flecher, Xavier
    Sporer, Scott
    Paprosky, Wayne
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (07) : 949 - 955
  • [9] Trabecular Titanium™ cups and augments in revision total hip arthroplasty: clinical results, radiology and survival outcomes
    Gallart, Xavier
    Fernandez-Valencia, Jenaro A.
    Riba, Josep
    Bori, Guillem
    Garcia, Sebastian
    Tornero, Eduard
    Combalia, Andreu
    [J]. HIP INTERNATIONAL, 2016, 26 (05) : 486 - 491
  • [10] Tritanium Acetabular Cup in Revision Hip Replacement: A Six to Ten Years of Follow-Up Study
    Hosny, Hazem A. H.
    El-Bakoury, Ahmed
    Srinivasan, Sreebala C. M.
    Yarlagadda, Rathan
    Keenan, Jonathan
    [J]. JOURNAL OF ARTHROPLASTY, 2018, 33 (08) : 2566 - 2570