Design-eligibility study of solar thermal helically coiled heat exchanging system with annular dimples by irreversibility concept

被引:28
作者
Cao, Yan [1 ]
Hashemian, Mehran [2 ]
Ayed, Hamdi [3 ]
Shawabkeh, Ali [4 ]
Issakhov, Alibek [5 ]
Wae-hayee, Makatar [6 ]
机构
[1] Xian Technol Univ, Sch Comp Sci & Engn, Xian 710021, Peoples R China
[2] Urmia Univ, Fac Engn, Dept Mech Engn, Orumiyeh, Iran
[3] King Khalid Univ, Coll Engn, Dept Civil Engn, Abha 61421, Saudi Arabia
[4] Amer Univ Middle East, Coll Engn & Technol, Kuwait, Kuwait
[5] al Farabi Kazakh Natl Univ, Dept Math & Comp Modelling, Alma Ata 50040, Kazakhstan
[6] Prince Songkla Univ, Fac Engn, Dept Mech & Mechatron Engn, Hat Yai 90110, Songkhla, Thailand
关键词
Heat transfer improvement; Solar thermal; Entropy; Exergy; 2ND LAW ANALYSIS; PERFORMANCE; ENHANCEMENT; COLLECTORS;
D O I
10.1016/j.renene.2021.10.095
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This is a numerical research that aims to design several helically grooved coils for solar water heating systems and compare them based on the irreversibility concept. To this end, helical coils with circle, square, horizontal elongated circle (HEC), and vertical elongated circle (VEC) cross-sections were annularly grooved for enhancing heat transfer rate. The Second law analysis in this study was performed based on several variables including flow rate (1-6 lit/min), geometrical, temperature (283-323K), and type of working fluid. Depth and distance of grooves were considered as geometrical parameters. Water, EG (CH2OH)(2)(IUPAC name: ethane-1,2-diol), and Theminol-55 were used as heat transfer fluids. Selected fluids make a Pr range of 3.35-744. Various entropy-based indicators were used to select the most optimum condition. Moreover, the interactions between triple thermodynamic domains (energy, entropy, and exergy) were conceptualized. Results demonstrated that for all cases the highest entropy generation can be achieved in the higher flow rates (6 lit/min), also when groove depth and distance are, respectively, 1.3 mm and 20 mm. Case "VEC" has the lowest ratio of grooved dimensionless entropy to un-grooved dimensionless entropy. (C) 2021 Elsevier Ltd. All rights reserved.
引用
收藏
页码:369 / 384
页数:16
相关论文
共 50 条
[1]   Hydrothermal irreversibility analysis based on multi-criteria assessment in a modified spiral piping system utilized in solar ponds [J].
Abu-Hamdeh, Nidal H. ;
Oztop, Hakan F. ;
Alnefaie, Khalid A. ;
Wae-hayee, Makatar .
RENEWABLE ENERGY, 2020, 162 :355-370
[2]   Effects of ribs on thermal performance of curved absorber tube used in cylindrical solar collectors [J].
Abu-Hamdeh, Nidal H. ;
Bantan, Rashad A. R. ;
Khoshvaght-Aliabadi, Morteza ;
Alimoradi, Ashkan .
RENEWABLE ENERGY, 2020, 161 :1260-1275
[3]   Recent residential applications of low-temperature solar collector [J].
Ahmadi, A. ;
Ehyaei, M. A. ;
Doustgani, A. ;
Assad, M. El Haj ;
Hmida, A. ;
Jamali, D. H. ;
Kumar, R. ;
Li, Z. X. ;
Razmjoo, A. .
JOURNAL OF CLEANER PRODUCTION, 2021, 279 (279)
[4]   Thermal, frictional and exergetic analysis of non-parallel configurations for plate heat exchangers [J].
Al-Turki, Yusuf A. ;
Moria, Hazim ;
Shawabkeh, Ali ;
Pourhedayat, Samira ;
Hashemian, Mehran ;
Dizaji, Hamed Sadighi .
CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2021, 161
[5]   Analysis of a solar air heater for augmented thermohydraulic performance using helicoidal spring shaped fins-A numerical study [J].
Arunkumar, H. S. ;
Kumar, Shiva ;
Karanth, K. Vasudeva .
RENEWABLE ENERGY, 2020, 160 :297-311
[7]  
Assad MEH, 2000, INT J ENERG RES, V24, P865, DOI 10.1002/1099-114X(200008)24:10<865::AID-ER629>3.0.CO
[8]  
2-O
[9]   ε-NTU analysis of turbulent flow in a corrugated double pipe heat exchanger: A numerical investigation [J].
Bashtani, Iman ;
Esfahani, Javad Abolfazli .
APPLIED THERMAL ENGINEERING, 2019, 159
[10]   Inducing swirl flow inside the pipes of flat-plate solar collector by using multiple nozzles for enhancing thermal performance [J].
Cao, Yan ;
Ayed, Hamdi ;
Hashemian, Mehran ;
Issakhov, Alibek ;
Jarad, Fahd ;
Wae-hayee, Makatar .
RENEWABLE ENERGY, 2021, 180 (180) :1344-1357