Employment of electrostriction phenomenon for label-free electrochemical immunosensing of tetracycline

被引:19
作者
Starzec, Karolina [1 ]
Cristea, Cecilia [2 ]
Tertis, Mihaela [2 ]
Feier, Bogdan [2 ]
Wieczorek, Marcin [1 ]
Koscielniak, Pawel [1 ]
Kochana, Jolanta [1 ]
机构
[1] Jagiellonian Univ, Fac Chem, Dept Analyt Chem, Gronostajowa 2, PL-30387 Krakow, Poland
[2] Iuliu Hatieganu Univ Med & Pharm, Fac Pharm, Dept Analyt Chem, 4 Louis Pasteur St, Cluj Napoca 400349, Romania
关键词
Immunosensor; Antibacterial resistance; Tetracycline; SAM; Capacitive sensor; ANTIBIOTICS RESIDUES; CAPACITIVE SENSOR; IMMUNOASSAY; CARBON; MILK; ELECTRODE; IMPEDANCE;
D O I
10.1016/j.bioelechem.2019.107405
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The presented work describes a simple label-free electrochemical immunosensor for the determination of tetracycline (TC). The functioning of the sensor was based on the electrostriction of a antibody-terminated thiol layer self-assembled on a gold electrode surface, serving as a dielectric membrane. The intensity of electrostriction was correlated with the amount of TC captured through an affinity reaction with its specific antibody, and was followed in the form of capacitance-potential curves. The process of the immunosensor construction was optimized using electrochemical impedance spectroscopy (EIS). The chemisorption time of the thiol, the duration of the TCAb immobilization and its concentration were optimized. The developed immunosensor exhibited a linear response in two concentration ranges: from 0.95 to 10 mu mol L-1 and from 10 to 140 mu mol L-1, with the mean sensitivity of 6.27 nF mu mol(-1) L (88.67 nF mu mol(-1) L cm(-2)) and 0.56 nF mu mol(-1) L (7.84 nF mu mol(-1) L cm(-2)), respectively. The limit of detection was evaluated as 28 nmol L-1. The specificity of the proposed sensor toward other antibiotics, amoxicillin and ciprofloxacin, was examined. The immunosensor was successfully employed to quantify TC in a tablet form and in a matrix of river water. (C) 2019 The Authors. Published by Elsevier B.V.
引用
收藏
页数:11
相关论文
共 48 条
[11]   Ultralow Cost Electrochemical Sensor Made of Potato Starch and Carbon Black Nanoballs to Detect Tetracycline in Waters and Milk [J].
Delgado, Karina P. ;
Raymundo-Pereira, Paulo A. ;
Campos, Anderson M. ;
Oliveira, Osvaldo N., Jr. ;
Janegitz, Bruno C. .
ELECTROANALYSIS, 2018, 30 (09) :2153-2159
[12]   Electrochemical determination of tetracycline using AuNP-coated molecularly imprinted overoxidized polypyrrole sensing interface [J].
Devkota, Lavaraj ;
Nguyen, Loc. T. ;
Thu Thi Vu ;
Piro, Benoit .
ELECTROCHIMICA ACTA, 2018, 270 :535-542
[13]   Determination of Tetracycline on the Surface of a High-Performance Graphene Modified Screen-Printed Carbon Electrode in Milk and Honey Samples [J].
Filik, Hayati ;
Avan, Asiye A. ;
Aydar, Sevda ;
Ozyurt, Dilek ;
Demirata, Birsen .
CURRENT NANOSCIENCE, 2016, 12 (04) :527-533
[14]   Gold cleaning methods for electrochemical detection applications [J].
Fischer, Lee M. ;
Tenje, Maria ;
Heiskanen, Arto R. ;
Masuda, Noriyuki ;
Castillo, Jaime ;
Bentien, Anders ;
Emneus, Jenny ;
Jakobsen, Mogens H. ;
Boisen, Anja .
MICROELECTRONIC ENGINEERING, 2009, 86 (4-6) :1282-1285
[15]   Immunoassay and amperometric biosensor approaches for the detection of deltamethrin in seawater [J].
Fruhmann, Philipp ;
Sanchis, Ana ;
Mayerhuber, Lisa ;
Vanka, Tuende ;
Kleber, Christoph ;
Salvador, J. -Pablo ;
Marco, M. -Pilar .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2018, 410 (23) :5923-5930
[16]   Simple and novel electrochemical sensor for the determination of tetracycline based on iron/zinc cations-exchanged montmorillonite catalyst [J].
Gan, Tian ;
Shi, Zhaoxia ;
Sun, Junyong ;
Liu, Yanming .
TALANTA, 2014, 121 :187-193
[17]   Optimization of a modified QuEChERS method for the determination of tetracyclines in fish muscle by UHPLC-MS/MS [J].
Grande-Martinez, Angel ;
Moreno-Gonzalez, David ;
Arrebola-Liebanas, Francisco J. ;
Garrido-Frenich, Antonia ;
Garcia-Campana, Ana M. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 155 :27-32
[18]   A unified approach for high-throughput quantitative analysis of the residues of multi-class veterinary drugs and pesticides in bovine milk using LC-MS/MS and GC-MS/MS [J].
Jadhav, Manjusha R. ;
Pudale, Anjali ;
Raut, Prakash ;
Utture, Sagar ;
Shabeer, T. P. Ahammed ;
Banerjee, Kaushik .
FOOD CHEMISTRY, 2019, 272 :292-305
[19]   CPE analysis by local electrochemical impedance spectroscopy [J].
Jorcin, JB ;
Orazem, ME ;
Pébère, N ;
Tribollet, B .
ELECTROCHIMICA ACTA, 2006, 51 (8-9) :1473-1479
[20]   A 4-ELECTRODE SYSTEM FOR MEASUREMENT OF BILAYER-LIPID MEMBRANE CAPACITANCE [J].
KALINOWSKI, S ;
FIGASZEWSKI, Z .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1995, 6 (07) :1043-1049