Energy consumption of paraplegic locomotion using reciprocating gait orthosis

被引:16
作者
Beillot, J
Carre, F
LeClaire, G
Thoumie, P
PerruoinVerbe, B
Cormerais, A
Courtillon, A
Tanguy, E
Nadeau, G
Rochcongar, P
Dassonville, J
机构
[1] CTR REEDUC FONCT KERPAPE,LORIENT,FRANCE
[2] HOP BICHAT C BERNARD,SERV REEDUC FONCT,PARIS,FRANCE
[3] HOP ST JACQUES,SERV REEDUC FONCT,NANTES,FRANCE
[4] CTR REEDUC FONCT BEAULIEU,RENNES,FRANCE
[5] CTR REEDUC FONCT PEN BRON,LA TURBALLE,FRANCE
[6] CTR REEDUC FONCT ARCHE,LE MANS,FRANCE
来源
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY | 1996年 / 73卷 / 3-4期
关键词
paraplegic; hybrid orthosis; gait; oxygen uptake;
D O I
10.1007/BF02425502
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
The energy cost of walking using a reciprocating gait orthosis (RGOII) with functional electrical stimulation (FES) was assessed in 14 patients with spastic complete paraplegia from six rehabilitation centres, Before and after training asing RGOII with FES, the subjects performed a progressive maximal test on an arm-crank ergometer to obtain their laboratory peak oxygen uptake (LVO(2peak)), heart rate (HR) and blood lactate concentration changes. At the end of the training session, oxygen uptake (VO2) was measured during a walking test with orthosis at different speeds (6 min steady state at 0.1 m . s(-1), followed by 2-min stages at progressively increasing speeds up to exhaustion). Of the subjects 4 repeated this test using orthosis without FES. At a speed of 0.1 m . s(-1), VO2 represented 47 (SD 23)% of LVO(2peak), mean HR was 137 (SD 21) beats . min(-1) and mean blood lactate concentration 2.4 (SD 1.4) mmol . l(-1). Maximal speed ranged from 0.23 to 0.5 m . s(-1). At maximal speed, VO2 was 91 (SD 18)% of LVO(2peak), mean HR reached 96 (SD 7)% and mean blood lactate concentration only 52 (SD 19)% of the maximal values measured during the laboratory test, Walking without electrical stimulation induced an increase in HR but there was no difference in VO2 and blood lactate compared to walking with stimulation. The training period did not result in any improvement in maximal physiological data, We concluded that the free cadence walking speed with orthosis remains much lower than that of able-bodied people or wheelchair users, The metabolic cost at a given speed is much higher even if, using a stimulation device, the cardiovascular stress is reduced.
引用
收藏
页码:376 / 381
页数:6
相关论文
共 30 条
  • [1] MAXIMAL OXYGEN-UPTAKE DURING EXERCISE WITH VARIOUS COMBINATIONS OF ARM AND LEG WORK
    BERGH, U
    KANSTRUP, IL
    EKBLOM, B
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1976, 41 (02) : 191 - 196
  • [2] BESSOU P, 1988, J PHYSIOL-PARIS, V83, P102
  • [3] BILLAT V, 1995, J SPORT MED PHYS FIT, V35, P20
  • [4] WALKING AND WHEELCHAIR ENERGETICS IN PERSONS WITH PARAPLEGIA
    CERNY, K
    WATERS, R
    HISLOP, H
    PERRY, J
    [J]. PHYSICAL THERAPY, 1980, 60 (09): : 1133 - 1139
  • [5] CLINKINGBEARD J R, 1964, Am J Phys Med, V43, P157
  • [6] COONEY MM, 1986, MED SCI SPORT EXER, V18, P522
  • [7] CARDIOVASCULAR-RESPONSES TO ARM CRANKING AND FNS-INDUCED LEG EXERCISE IN PARAPLEGICS
    DAVIS, GM
    SERVEDIO, FJ
    GLASER, RM
    GUPTA, SC
    SURYAPRASAD, AG
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1990, 69 (02) : 671 - 677
  • [8] EFFECT OF ARM ERGOMETRY TRAINING ON PHYSICAL WORK CAPACITY OF INDIVIDUALS WITH SPINAL-CORD INJURIES
    DICARLO, SE
    SUPP, MD
    TAYLOR, HC
    [J]. PHYSICAL THERAPY, 1983, 63 (07): : 1104 - 1107
  • [9] AEROBIC PERFORMANCE CAPACITY IN PARAPLEGIC SUBJECTS
    FLANDROIS, R
    GRANDMONTAGNE, M
    GERIN, H
    MAYET, MH
    JEHL, JL
    EYSSETTE, M
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 55 (06): : 604 - 609
  • [10] Glaser R M, 1985, Exerc Sport Sci Rev, V13, P263