Impact of left ventricular unloading using a peripheral Impella®-pump in eCPR patients

被引:16
|
作者
Gaisendrees, Christopher [1 ]
Djordjevic, Ilija [1 ]
Sabashnikov, Anton [1 ]
Adler, Christopher [2 ]
Eghbalzadeh, Kaveh [1 ]
Ivanov, Borko [1 ]
Walter, Sebastian [1 ]
Schlachtenberger, Georg [1 ]
Merkle-Storms, Julia [1 ]
Gerfer, Stephen [1 ]
Carstens, Henning [1 ]
Deppe, Antje-Christin [1 ]
Kuhn, Elmar [1 ]
Wahlers, Thorsten [1 ]
机构
[1] Univ Hosp Cologne, Dept Cardiothorac Surg, Kerpener Str 62, D-50937 Cologne, Germany
[2] Univ Hosp Cologne, Dept Cardiol, Cologne, Germany
关键词
assist device; cardiogenic shock; ECMO; eCPR; Impella; LV-unloading; mechanical circulatory devices; EXTRACORPOREAL MEMBRANE-OXYGENATION; CRITICALLY-ILL PATIENTS; CARDIOPULMONARY-RESUSCITATION; SURVIVAL; THERAPY; SUPPORT;
D O I
10.1111/aor.14067
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Background Extracorporeal cardiopulmonary resuscitation (eCPR) is a rapidly growing treatment strategy due to increasing survival rates in selected patients. Additional left ventricular mechanical unloading, using a transfemoral micro-axial blood pump (Impella (R) Denver, Massachusetts, USA), might improve patients' outcomes. In this regard, we sought to investigate patients who suffered OHCA (out-of hospital cardiac arrest) or IHCA (in-hospital cardiac arrest) with subsequent eCPR via VA-ECMO (veno-arterial extracorporeal membrane oxygenation) and concomitant Impella (R) implantation based on survival and feasibility of ECMO weaning. Methods From January 2016 until December 2020, 108 patients underwent eCPR at our institution. Data prior to eCPR and early outcome parameters were analyzed comparing patients who were supported with an additional Impella (R) (2.5 or CP) (ECMO+Impella (R), n = 18) and patients without additional (ECMO, n = 90) support during V-A ECMO therapy. The primary endpoint was in-hospital mortality; secondary endpoints were, among others: ECMO explantation, need for hemodialysis, stroke, and need for blood transfusions. Results Low-flow time was significantly lower in the ECMO+Impella group (60 min vs. 55 min, p = .01). All-cause mortality was significantly lower in the ECMO+Impella (R) group (82% vs. 56%, p = .01). The time of circulatory support was shorter in the ECMO cohort (2.0 +/- 1.73 vs. 4.76 +/- 2.88 p = .05). ECMO decannulation was significantly more feasible in patients with ECMO+Impella (R) (72% vs. 32%, p = .01). Patients treated with additional Impella (R) showed significantly more acute kidney injury with the need for dialysis (72% vs. 18%, p <= .01). Conclusion Concomitant Impella (R) support might positively influence survival and ECMO weaning in eCPR patients. Treatment-associated complications such as the need for dialysis were more common in this highly selected patient group. Further studies with larger numbers are necessary to evaluate the clinical relevance of concomitant LV-unloading in eCPR patients using an Impella (R) device.
引用
收藏
页码:451 / 459
页数:9
相关论文
共 50 条
  • [21] Mortality in patients with cardiogenic shock treated with the Impella CP microaxial pump for isolated left ventricular failure
    Sieweke, Jan-Thorben
    Berliner, Dominik
    Tongers, Joern
    Napp, L. Christian
    Flierl, Ulrike
    Zauner, Florian
    Bauersachs, Johann
    Schaefer, Andreas
    EUROPEAN HEART JOURNAL-ACUTE CARDIOVASCULAR CARE, 2020, 9 (02) : 138 - 148
  • [22] Effect of Left Ventricular Unloading by Pump Speed Adjustment on Myocardial Flow in Continuous-flow Left Ventricular Assist Device Patients
    Yuzefpolskaya, Melana
    Ladanyi, Annamaria
    Bokhari, Sabahat
    Jorde, Ulrich P.
    Colombo, Paolo C.
    ASAIO JOURNAL, 2023, 69 (05) : 460 - 466
  • [23] Less Invasive Left Ventricular Unloading With Impella May Improve the Clinical Outcomes of Fulminant Myocarditis
    Kawamura, Takuji
    Toda, Koichi
    Yoshioka, Daisuke
    Kawamura, Masashi
    Saito, Tetsuya
    Kawamura, Ai
    Nakamoto, Kei
    Sakata, Yasushi
    Miyagawa, Shigeru
    ASAIO JOURNAL, 2023, 69 (06) : 561 - 568
  • [24] Venoarterial extracorporeal membrane oxygenation (VA-ECMO) with vs. without left ventricular unloading by Impella: a systematic review and meta-analysis
    Cappannoli, Luigi
    Galli, Mattia
    Zito, Andrea
    Restivo, Attilio
    Princi, Giuseppe
    Laborante, Renzo
    Vergallo, Rocco
    Romagnoli, Enrico
    Leone, Antonio Maria
    Aurigemma, Cristina
    Massetti, Massimo
    Sanna, Tommaso
    Trani, Carlo
    Burzotta, Francesco
    Savarese, Gianluigi
    Crea, Filippo
    D'Amario, Domenico
    EUROPEAN HEART JOURNAL-QUALITY OF CARE AND CLINICAL OUTCOMES, 2023, 9 (04) : 358 - 366
  • [25] Left Ventricular Mechanical Support with Impella Provides More Ventricular Unloading in Heart Failure Than Extracorporeal Membrane Oxygenation
    Kawashima, Dai
    Gojo, Satoshi
    Nishimura, Takashi
    Itoda, Yoshihumi
    Kitahori, Kazuo
    Motomura, Noboru
    Morota, Tetsuro
    Murakami, Arata
    Takamoto, Shinichi
    Kyo, Shunei
    Ono, Minoru
    ASAIO JOURNAL, 2011, 57 (03) : 169 - 176
  • [26] Prediction of survival of patients in cardiogenic shock treated by surgically implanted Impella 5+short-term left ventricular assist device
    Nersesian, Gaik
    Tschope, Carsten
    Spillmann, Frank
    Gromann, Tom
    Roehrich, Luise
    Mueller, Marcus
    Mulzer, Johanna
    Starck, Christoph
    Falk, Volkmar
    Schoenrath, Felix
    Potapov, Evgenij
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2020, 31 (04) : 475 - 482
  • [27] Left ventricular unloading during extracorporeal life support for myocardial infarction with cardiogenic shock: surgical venting versus Impella device
    Radakovic, Darko
    Zittermann, Armin
    Knezevic, Alen
    Razumov, Artyom
    Opacic, Dragan
    Wienrautner, Nicole
    Flottmann, Christian
    Rojas, Sebastian, V
    Fox, Henrik
    Schramm, Rene
    Morshuis, Michiel
    Rudolph, Volker
    Gummert, Jan
    Deutsch, Marcus-Andre
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2022, 34 (01) : 137 - 144
  • [28] Impella CP or VA-ECMO in profound cardiogenic shock: left ventricular unloading and organ perfusion in a large animal model
    Moller-Helgestad, Ole K.
    Hyldebrandt, Janus A.
    Banke, Ann
    Rud, Charlotte S.
    Udesen, Nanna L. J.
    Linde, Louise
    Jensen, Lisette O.
    Schmidt, Henrik
    Ravn, Hanne B.
    Moller, Jacob E.
    EUROINTERVENTION, 2019, 14 (15) : E1585 - E1592
  • [29] Estimation of left ventricular pressure with the pump as "sensor" in patients with a continuous flow LVAD
    Pennings, Kim A. M. A.
    van Tuijl, Sjoerd
    van de Vosse, Frans N.
    de Mol, Bas A. J.
    Rutten, Marcel C. M.
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2015, 38 (08) : 433 - 443
  • [30] Real-World Data on the Intravascular Microaxial Left Ventricular Flow Pump (Impella) in High-Risk Patients
    Rao, Sunil, V
    KOREAN CIRCULATION JOURNAL, 2021, 51 (06) : 487 - 494