Evaluation of a Body-Worn Sensor System to Measure Physical Activity in Older People With Impaired Function

被引:221
作者
Taraldsen, Kristin [1 ,2 ]
Askim, Torunn [1 ]
Sletvold, Olav [1 ,2 ]
Einarsen, Elin Kristin [2 ]
Bjastad, Karianne Gruner [3 ]
Indredavik, Bent [1 ,4 ]
Helbostad, Jorunn Laegdheim [1 ,2 ]
机构
[1] Norwegian Univ Sci & Technol, Fac Med, Dept Neurosci, N-7034 Trondheim, Norway
[2] Univ Trondheim Hosp, Dept Geriatr, St Olavs Hosp, N-7006 Trondheim, Norway
[3] Univ Trondheim Hosp, Clin Serv, St Olavs Hosp, N-7006 Trondheim, Norway
[4] Univ Trondheim Hosp, Stroke Unit, St Olavs Hosp, N-7006 Trondheim, Norway
来源
PHYSICAL THERAPY | 2011年 / 91卷 / 02期
关键词
ACTIVITY-MONITOR; VALIDATION; VALIDITY; MOBILITY; ACCELEROMETRY; RELIABILITY; PERFORMANCE; GO;
D O I
10.2522/ptj.20100159
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background. There is limited information on reliable and valid measures of physical activity in older people with impaired function. Objective. This study was conducted to compare the accuracy of single-axis accelerometers in recognizing postures and transitions and step counting with the accuracy of video recordings in people with stroke (n = 14), older inpatients (n = 14), people with hip fracture (n = 8), and a reference group of 10 adults who were healthy. Design. This was a cross-sectional study, evaluating the concurrent validity of small body-worn accelerometers against video observations as the criterion measure. Methods. Activity data were collected from 3 sensors (activPAL) attached to the thighs and the sternum and from registration of the same activities from video recordings. Participants performed a test protocol of in-bed, transfer, and walking activities. Results. The sensor system was highly accurate in classifying lying, sitting, and standing positions (100%) and in recognizing transitions from lying to sitting positions and from sitting to standing positions (100%). Placement of a sensor on the nonaffected leg resulted in less underestimation of step counts than placement on the affected leg. Still, the sensor system underestimated step counts during walking, especially at slow walking speeds (<= 0.47 m/s) (limits of agreement = -2.01 to 16.54, absolute percent error=40.31). Limitations. The study was performed in a controlled setting and not during the natural performance of activities. Conclusions. The activPAL sensor system provides valid measures of postures and transitions in older people with impaired walking ability. Step counting needs to be improved for the sensor system to be acceptable for this population, especially at slow walking speeds.
引用
收藏
页码:277 / 285
页数:9
相关论文
共 23 条
[1]   Physical activity monitoring based on accelerometry: validation and comparison with video observation [J].
Aminian, K ;
Robert, P ;
Buchser, EE ;
Rutschmann, B ;
Hayoz, D ;
Depairon, M .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1999, 37 (03) :304-308
[2]  
[Anonymous], ActivPAL
[3]  
Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
[4]   Reliability and concurrent validity of the Expanded Timed Up-and-Go test in older people with impaired mobility [J].
Botolfsen, Pernille ;
Helbostad, Jorunn L. ;
Moe-Nilssen, Rolf ;
Wall, James C. .
PHYSIOTHERAPY RESEARCH INTERNATIONAL, 2008, 13 (02) :94-106
[5]   Ambulatory accelerometry to quantify motor behaviour in patients after failed back surgery: a validation study [J].
Bussmann, JBJ ;
van de Laar, YM ;
Neeleman, MP ;
Stam, HJ .
PAIN, 1998, 74 (2-3) :153-161
[6]   Wearable systems for monitoring mobility-related activities in older people: a systematic review [J].
de Bruin, Eling D. ;
Hartmann, Antonia ;
Uebelhart, Daniel ;
Murer, Kurt ;
Zijlstra, Wiebren .
CLINICAL REHABILITATION, 2008, 22 (10-11) :878-895
[7]   Comparison of the performance of the activPAL™ Professional physical activity logger to a discrete accelerometer-based activity monitor [J].
Godfrey, A. ;
Culhane, K. M. ;
Lyons, G. M. .
MEDICAL ENGINEERING & PHYSICS, 2007, 29 (08) :930-934
[8]   The validation of a novel activity monitor in the measurement of posture and motion during everyday activities [J].
Grant, P. M. ;
Ryan, C. G. ;
Tigbe, W. W. ;
Granat, M. H. .
BRITISH JOURNAL OF SPORTS MEDICINE, 2006, 40 (12) :992-997
[9]   Activity-monitor accuracy in measuring step number and cadence in community-dwelling older adults [J].
Grant, P. Margaret ;
Dall, Philippa M. ;
Mitchell, Sarah L. ;
Granat, Malcolm H. .
JOURNAL OF AGING AND PHYSICAL ACTIVITY, 2008, 16 (02) :201-214
[10]   Treatment in a combined acute and rehabilitation stroke unit -: Which aspects are most important? [J].
Indredavik, B ;
Bakke, F ;
Slordahl, SA ;
Rokseth, R ;
Håheim, LL .
STROKE, 1999, 30 (05) :917-923