A Monitoring Method for Average Winding and Hot-Spot Temperatures of Single-Phase, Oil-Immersed Transformers

被引:29
作者
Gezegin, Cenk [1 ]
Ozgonenel, Okan [1 ]
Dirik, Hasan [2 ]
机构
[1] Ondokuz Mayis Univ, Dept Elect & Elect Engn, TR-55139 Samsun, Turkey
[2] Sinop Univ, Vocat Sch, TR-57000 Sinop, Turkey
关键词
Windings; Oil insulation; Power transformer insulation; Resistance; Temperature; Oils; Temperature sensors; Average winding temperature (AWT); hot spot factor (HSF); hot spot temperature (HST); top oil temperature (TOT); monitoring; finite element method (FEM); POWER TRANSFORMERS;
D O I
10.1109/TPWRD.2020.3035842
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Transformers are the most expensive element of a power system, and so transformer monitoring systems are becoming more important as loads increase. Under heavy loading conditions, the hot-spot temperature of a transformer is the most critical parameter to determine the limit of loading. Therefore, to make an accurate estimation of hot-spot temperature and maintain the reliability of a power system, dynamic thermal models or methods must be employed. Due to the complexity of thermal phenomena, the methods presented so far needs to be improved to reduce computational errors. This is particularly the case for variable loading conditions and power utilities are still in need of good techniques. This paper describes two methods to determine temperature in single-phase, oil-immersed transformers. The first method calculates average windings temperature (AWT) using the voltage and current from primary and secondary windings. The second method, which uses data from the first method, determines the hot-spot temperature of the transformer. The methods have been investigated by experiments on a 30 kVA single-phase transformer and verified the results using COMSOL (TM) software. Our methods have proven more accurate than the IEEE Annex G method.
引用
收藏
页码:3196 / 3203
页数:8
相关论文
共 24 条
[1]  
[Anonymous], 2011, IEC 60076-1
[2]  
[Anonymous], 2014, C571342013 IEEE
[3]  
[Anonymous], 2017, C5712902015COR12017
[4]  
[Anonymous], 2008, 6007612 IEC
[5]  
Daghrah M, 2016, INT CONF CONDIT MON, P948, DOI 10.1109/CMD.2016.7757981
[6]   A Novel Parameter Identification Method for Single-Phase Transformers by Using Real-Time Data [J].
Dirik, Hasan ;
Gezegin, Cenk ;
Ozdemir, Muammer .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (03) :1074-1082
[7]   Evaluation of Power Transformers' Effective Hot-Spot Factors by Thermal Modeling of Scrapped Units [J].
Feng, Dongyin ;
Wang, Zhongdong ;
Jarman, Paul .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (05) :2077-2085
[8]   Measurement of eddy-current loss coefficient PEC-R, derating of single-phase transformers, and comparison with K-factor approach (vol 15, pg 148, 2000) [J].
Fuchs, EF ;
Yildirim, D ;
Grady, WM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) :1357-1357
[9]  
IEC,S, 2018, 6007672018RLV IEC
[10]  
IEEE Guide for Loading Mineral-Oil-Immersed Transformers and StepVoltage Regulators, 2011, C57912011 IEEE