A performance comparison of a nonlinear and a linear control for grid connected PMSG wind energy conversion system

被引:95
作者
Errami, Youssef [1 ]
Ouassaid, Mohammed [2 ]
Maaroufi, Mohamed [3 ]
机构
[1] Chouaib Doukkali Univ, Fac Sci, Dept Phys, El Jadida, Morocco
[2] Cadi Ayyad Univ, Natl Sch Applicat Sci ENSA Safi, Dept Ind Engn, Safi, Morocco
[3] Univ Mohammed V Agdal, Ecole Mohammadia Ingn, Dept Elect Engn, Rabat, Morocco
关键词
Wind farm; PMSG; MPPT; PFC control; Nonlinear control; Electric network connection; SLIDING MODE CONTROL; VOLTAGE RIDE-THROUGH; ACTIVE POWER FILTER; PARALLEL OPERATION; GENERATION SYSTEM; TURBINE; DESIGN; CONVERTER; TOPOLOGY; FARMS;
D O I
10.1016/j.ijepes.2014.12.027
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
With the increased penetration of wind energy on modern power systems all over the world, the Wind Farm Systems (WFS) are today required to participate actively in electric network operation by an appropriate generation control strategy. This paper presents a comparative study of two control strategies for wind farm based on Permanent Magnet Synchronous Generator (PMSG) and interconnected to the distribution network. The 4 MW wind farm consists of 2 PMSGs based on 2 MW generators connected to a common DC-bus system. Each PMSG of the WFS is connected to the DC-bus through a rectifier, but the DC-bus is connected to the grid through only one inverter system. The proposed control laws are based on a sliding mode algorithm and classical Proportional Integral (PI) controllers to regulate both generator and grid-side converters. The control strategy combines a pitch control scheme and Maximum Power Point Tracking (MPPT) to maximize the total generated power of WFS. Furthermore, the aim of the control strategy is to maximize the extracted power with the lowest possible impact in the power network voltage and frequency for fault conditions as well as for normal working conditions. Finally, simulation results with Matlab/Simulink environment confirm that the proposed strategy has excellent performance. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:180 / 194
页数:15
相关论文
共 89 条
[1]   Use of Stored Energy in PMSG Rotor Inertia for Low-Voltage Ride-Through in Back-to-Back NPC Converter-Based Wind Power Systems [J].
Alepuz, Salvador ;
Calle, Alejandro ;
Busquets-Monge, Sergio ;
Kouro, Samir ;
Wu, Bin .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (05) :1787-1796
[2]   Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips [J].
Alepuz, Salvador ;
Busquets-Monge, Sergio ;
Bordonau, Josep ;
Martinez-Velasco, Juan A. ;
Silva, Cesar A. ;
Pontt, Jorge ;
Rodriguez, Jose .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2009, 56 (06) :2162-2173
[3]  
[Anonymous], IEEE T IND ELECT
[4]  
[Anonymous], IEEE INT C POW EL DR
[5]  
[Anonymous], P 30 CHIN CONTR C IE
[6]  
[Anonymous], IEEE T POWER ELECT
[7]  
[Anonymous], IEEE AUSTR U POW ENG
[8]  
[Anonymous], IEEE T IND ELECT
[9]  
[Anonymous], 1999, Sliding mode control in electromechanical systems
[10]  
[Anonymous], VARIABLE SPEED WIND