A new equine pericardial stentless valve

被引:27
作者
Mueller, XM
von Segesser, LK
机构
[1] Univ Sherbrooke, Ctr Hosp, Dept Cardiovasc Surg, Sherbrooke, PQ J1H 5N4, Canada
[2] CHU Vaudois, Dept Cardiovasc Surg, Lausanne, Switzerland
关键词
D O I
10.1016/S0022-5223(02)73242-X
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Small aortic valve replacement remains a challenging hemodynamic problem. A new bioprosthesis (3F Therapeutics, Lake Forest, Calif) was designed to further improve the hemodynamic performance currently achieved with stentless bioprostheses. This valve consists of a tubular structure assembled from 3 equal sections of equine pericardial material, with virtually no foreign material except for a thin polyester ring. Its hemodynamic performance was compared with that of a commercially available stentless prosthesis in a bovine model. Patients and Methods: Twelve calves (55 +/- 2.8 kg) received a 19-mm 3F valve (317 group, n = 6) or a 19-mm stentless control valve (control group, n = 6). The animals were fully equipped for hemodynamic monitoring and transvalvular gradient measurements. After implantation, dopamine was infused in increasing doses, and the hemodynamic values were recorded at each step of 100-mug/min increase. Linear regression analysis was applied for group comparison of each variable. Results: The mean transvalvular gradient at 4.5 L/min was 3.48 +/- 0.14 rum Hg (95% confidence interval) in the 3F group and 5.72 +/- 0.28 rum Hg in the control group (P < .0001) and at 6.5 L/min, 7.4 +/- 1.55 mm Hg, and 11.13 +/- 0.18 rum Hg, respectively (P < .0001). The effective orifice area at 4.5 L/min was 2.4 +/- 0.03 cm(2) in the 3F group and 1.86 +/- 0.02 cm(2) in the control group (P < .0001) and at 6.5 L/min, 2.41 +/- 0.04 cm(2), and 1.96 +/- 0.02 cm(2), respectively (P < .0001). Conclusions: This new bioprosthesis without a stent and without a supporting wall that has its commissures fixed directly to the aorta outperforms in vivo standard stentless prostheses in the immediate postimplant period.
引用
收藏
页码:1405 / 1411
页数:7
相关论文
共 23 条
[1]   Hemodynamics and left ventricular mass regression following implantation of the Toronto SPV stentless porcine valve [J].
Bach, DS ;
David, T ;
Yacoub, M ;
Pepper, J ;
Goldman, B ;
Wood, J ;
Verrier, F ;
Petracek, M ;
Aldrete, V ;
Rosenbloom, M ;
Azar, H ;
Rakowski, H .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (10) :1214-1219
[2]  
BINET JP, 1965, LANCET, V2, P1275
[3]   AORTIC-VALVE RESISTANCE AS AN ADJUNCT TO THE GORLIN FORMULA IN ASSESSING THE SEVERITY OF AORTIC-STENOSIS IN SYMPTOMATIC PATIENTS [J].
CANNON, JD ;
ZILE, MR ;
CRAWFORD, FA ;
CARABELLO, BA .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (07) :1517-1523
[4]   BIOLOGICAL FACTORS AFFECTING LONG-TERM RESULTS OF VALVULAR HETEROGRAFTS [J].
CARPENTIER, A ;
LEMAIGRE, G ;
ROBERT, L ;
CARPENTIER, S ;
DUBOST, C ;
GERBODE, F .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1969, 58 (04) :467-+
[5]   Clinical and hemodynamic performance of the freestyle aortic root bioprosthesis [J].
Cartier, PC ;
Dumesnil, JG ;
Métras, J ;
Desaulniers, D ;
Doyle, DP ;
Lemieux, MD ;
Raymond, G .
ANNALS OF THORACIC SURGERY, 1999, 67 (02) :345-349
[6]   Left ventricular mass regression early after aortic valve replacement [J].
Christakis, GT ;
Joyner, CD ;
Morgan, CD ;
Fremes, SE ;
Buth, KJ ;
Sever, JY ;
Rao, V ;
Panagiotopoulos, KP ;
Murphy, PM ;
Goldman, BS .
ANNALS OF THORACIC SURGERY, 1996, 62 (04) :1084-1089
[7]  
COSGROVE DM, 1985, CIRCULATION, V72, P146
[8]  
David T E, 1988, J Card Surg, V3, P501, DOI 10.1111/j.1540-8191.1988.tb00444.x
[9]  
David TE, 1998, J HEART VALVE DIS, V7, P250
[10]  
David TE, 1999, CURR PROB SURG, V36, P426