A MEMS Capacitive Accelerometer Design as Middle Ear Microphone Based on Ossicular Chain Micromechanic Characterization at Umbo for Fully Implantable Cochlear Prosthesis

被引:0
作者
Zurcher, Mark A. [1 ]
Semaan, Maroun [2 ]
Megerian, Cliff A. [2 ]
Ko, Wen H. [1 ]
Young, Darrin J. [1 ]
机构
[1] Case Western Reserve Univ, Dept Elect Engn & Comp Sci, Cleveland, OH 44106 USA
[2] Univ Hosp Cleveland, Dept Otolaryngol Head & Neck Surg, Cleveland, OH 44106 USA
关键词
acoustic sensor; microphone; accelerometer; micromechanics; middle ear implant; biomedical implant; prosthesis; cochlear prosthesis; VIBRATION; MASS;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An accelerometer attached to an umbo is proposed as a middle ear microphone for future fully implantable cochlear prostheses. The micromechanic characterization of cadaveric temporal bones indicates that a miniature accelerometer with a sensing resolution of 35 mu g/root Hz, a bandwidth of 8 kHz, and a packaged weight less than 20 mg is required for detecting normal conversation, and that the accelerometer's performance is insensitive to potential position misalignment during the implant procedure. A commercial accelerometer is attached to an umbo as proof of the concept to demonstrate the capability of detecting and converting a temporal bone vibration to an electrical signal in response to an external acoustic stimulus. The commercial device, however, exhibits a high noise floor of 250 mu g/root Hz, and thus can only achieve minimum detectable sound pressure levels (SPL) of 82 dB and 55 dB at 500 Hz and 2.4 kHz, respectively, at a measurement bandwidth of 200 Hz, which is inadequate for the detection of normal conversation. A micro-electromechanical systems (MEMS) capacitive accelerometer is then designed with a sensing resolution of 30 mu g/root Hz in ambient limited by the Brownian noise and is fabricated using an SOI-MEMS process. The accelerometer occupies a sensing area of 1 mm(2) and achieves a nominal capacitance of 2.4 pF, a sensitivity of 4 fF/g, and a bandwidth of 6.44 kHz. The diced sensor chip has dimensions of approximately 2 mmx2.4 mmx0.4 mm, and hence, weighs 4.5 mg, which is suitable for the proposed fully implantable cochlear prosthesis.
引用
收藏
页码:297 / 312
页数:16
相关论文
共 14 条
[1]   MECHANICAL-THERMAL NOISE IN MICROMACHINED ACOUSTIC AND VIBRATION SENSORS [J].
GABRIELSON, TB .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1993, 40 (05) :903-909
[2]   Mass loading on the ossicles and middle ear function [J].
Gan, RZ ;
Dyer, RK ;
Wood, MW ;
Dormer, KJ .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2001, 110 (05) :478-485
[3]   Human middle ear transfer function measured by double laser interferometry system [J].
Gan, TZ ;
Wood, TW ;
Dormer, TJ .
OTOLOGY & NEUROTOLOGY, 2004, 25 (04) :423-435
[4]  
GOODE RL, 1993, AM J OTOL, V14, P247
[5]   Engineering principles applied to implantable otologic devices [J].
Ko, WH ;
Zhu, WL ;
Kane, M ;
Maniglia, AJ .
OTOLARYNGOLOGIC CLINICS OF NORTH AMERICA, 2001, 34 (02) :299-+
[6]  
Leysieffer H, 1998, HNO, V46, P853, DOI 10.1007/s001060050325
[7]   EFFECT OF CHANGES IN MASS ON MIDDLE-EAR FUNCTION [J].
NISHIHARA, S ;
ARITOMO, H ;
GOODE, RL .
OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1993, 109 (05) :899-910
[8]  
PARK WT, 2005, 13 INT C SOL STAT SE, P109
[9]   CADAVER MIDDLE EARS AS MODELS FOR LIVING EARS - COMPARISONS OF MIDDLE-EAR INPUT IMMITTANCE [J].
ROSOWSKI, JJ ;
DAVIS, PJ ;
DONAHUE, KM ;
MERCHANT, SN ;
COLTRERA, MD .
ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 1990, 99 (05) :403-412
[10]   Rehabilitation for high-frequency sensorineural hearing impairment in adults with the Symphonix Vibrant Soundbridge: A comparative study [J].
Uziel, A ;
Mondain, M ;
Hagen, P ;
Dejean, F ;
Doucet, G .
OTOLOGY & NEUROTOLOGY, 2003, 24 (05) :775-783