The accuracy of tomographic particle image velocimetry for measurements of a turbulent boundary layer

被引:96
作者
Atkinson, Callum [1 ,2 ]
Coudert, Sebastien [2 ]
Foucaut, Jean-Marc [2 ]
Stanislas, Michel [2 ]
Soria, Julio [1 ]
机构
[1] Monash Univ, Lab Turbulence Res Aerosp & Combust, Dept Mech & Aerosp Engn, Clayton, Vic 3800, Australia
[2] Ecole Cent Lille, CNRS, Lab Mecan Lille, UMR 8107, F-59655 Villeneuve Dascq, France
关键词
PIV; OPTIMIZATION; DEFORMATION;
D O I
10.1007/s00348-010-1004-z
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
To investigate the accuracy of tomographic particle image velocimetry (Tomo-PIV) for turbulent boundary layer measurements, a series of synthetic image-based simulations and practical experiments are performed on a high Reynolds number turbulent boundary layer at Re-theta = 7,800. Two different approaches to Tomo-PIV are examined using a full-volume slab measurement and a thin-volume "fat" light sheet approach. Tomographic reconstruction is performed using both the standard MART technique and the more efficient MLOS-SMART approach, showing a 10-time increase in processing speed. Random and bias errors are quantified under the influence of the near-wall velocity gradient, reconstruction method, ghost particles, seeding density and volume thickness, using synthetic images. Experimental Tomo-PIV results are compared with hot-wire measurements and errors are examined in terms of the measured mean and fluctuating profiles, probability density functions of the fluctuations, distributions of fluctuating divergence through the volume and velocity power spectra. Velocity gradients have a large effect on errors near the wall and also increase the errors associated with ghost particles, which convect at mean velocities through the volume thickness. Tomo-PIV provides accurate experimental measurements at low wave numbers; however, reconstruction introduces high noise levels that reduces the effective spatial resolution. A thinner volume is shown to provide a higher measurement accuracy at the expense of the measurement domain, albeit still at a lower effective spatial resolution than planar and Stereo-PIV.
引用
收藏
页码:1031 / 1056
页数:26
相关论文
共 38 条
[1]  
ADRIAN RJ, 1991, ANNU REV FLUID MECH, V23, P261, DOI 10.1146/annurev.fluid.23.1.261
[2]  
[Anonymous], 1975, TURBULENCE
[3]  
ATKINSON C, 2009, EXP FLUIDS UNPUB
[4]  
Atkinson CH, 2008, 14 INT S APPL LAS TE
[5]  
Baur T., 2000, EUROMECH, V411
[6]   Experimental study of eddy structures in a turbulent boundary layer using particle image velocimetry [J].
Carlier, J ;
Stanislas, M .
JOURNAL OF FLUID MECHANICS, 2005, 535 :143-188
[7]  
CARLIER J, 2001, THESIS U DELILLE FRA
[8]   A GENERAL CLASSIFICATION OF 3-DIMENSIONAL FLOW-FIELDS [J].
CHONG, MS ;
PERRY, AE ;
CANTWELL, BJ .
PHYSICS OF FLUIDS A-FLUID DYNAMICS, 1990, 2 (05) :765-777
[9]  
Elsinga G., 2006, 13 INT S APPL LAS TE
[10]   Tomographic particle image velocimetry [J].
Elsinga, G. E. ;
Scarano, F. ;
Wieneke, B. ;
van Oudheusden, B. W. .
EXPERIMENTS IN FLUIDS, 2006, 41 (06) :933-947