Perforation of the right ventricle by transvenous defibrillator leads: Prevention and treatment

被引:32
作者
Molina, JE [1 ]
机构
[1] UNIV MINNESOTA HOSP & CLIN,DIV THORAC & CARDIOVASC SURG,MINNEAPOLIS,MN
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1996年 / 19卷 / 03期
关键词
cardiac perforation; transvenous defibrillator leads; cardiac tamponade;
D O I
10.1111/j.1540-8159.1996.tb03329.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A series of 78 consecutive implants of the transvene PCD (Medtronic, Inc.) defibrillator system is presented and the occurrence of right ventricular perforation in 4 patients reported (5.2%). Diagnosis of perforation is made using four signs: (1) decrease in arterial blood pressure without any other explanation; (2) decrease in pulsatility of the cardiac silhouette as monitored by fluoroscopy; (3) increased size of the cardiac silhouette; and (4) abnormal position of the transvenous lead too far out toward the left ventricle along the pericardial outline. Perforation causes rapid and dramatic cardiac tamponade due to the large diameter and stiffness of the coil carrier lead. Immediate drainage of the hemopericardium must be carried out using the transxiphoid approach, The use of a thin blue-coded lead stylet (0.014-inch gauge) is recommended over the stiffer maroon-coded stylet. Since treatment must be carried out immediately, it is advised that a surgeon either perform, assist, or be immediately available whenever one of these systems is implanted.
引用
收藏
页码:288 / 292
页数:5
相关论文
共 17 条
[1]  
BAROLD SS, 1969, AM J CARDIOL, V24, P274
[2]  
BASSAN MM, 1977, J THORAC CARDIOV SUR, V74, P51
[3]   PERMANENT PACEMAKERS - 8-YEAR FOLLOW-UP STUDY - INCIDENCE AND MANAGEMENT OF CONGESTIVE CARDIAC FAILURE AND PERFORATIONS [J].
BERNSTEIN, V ;
ROTEM, E ;
PERETZ, DI .
ANNALS OF INTERNAL MEDICINE, 1971, 74 (03) :361-+
[4]   MANAGEMENT OF CARDIAC TAMPONADE - DRAINAGE OF PERICARDIAL EFFUSIONS [J].
CASSELL, P ;
CULLUM, P .
BRITISH JOURNAL OF SURGERY, 1967, 54 (07) :620-&
[5]   SUBXIPHOID PERICARDIAL WINDOW - SIMPLE AND SAFE METHOD FOR DIAGNOSING AND TREATING ACUTE AND CHRONIC PERICARDIAL EFFUSIONS [J].
FONTENELLE, LJ ;
CUELLO, L ;
DOOLEY, BN .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1971, 62 (01) :95-+
[6]   COMPLICATIONS OF PERMANENT TRANSVENOUS CARDIAC PACING - A 14-YEAR REVIEW OF ALL TRANSVENOUS PACEMAKERS INSERTED AT ONE COMMUNITY-HOSPITAL [J].
HILL, PE .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1987, 10 (03) :564-570
[7]  
IMPARATO AM, 1972, ARCH SURG-CHICAGO, V105, P705
[8]   COMPARISON OF LEAD COMPLICATIONS WITH POLYURETHANE TINED, SILICONE-RUBBER TINED, AND WEDGE TIP LEADS - CLINICAL-EXPERIENCE WITH 822 VENTRICULAR ENDOCARDIAL LEADS [J].
KERTES, P ;
MOND, H ;
SLOMAN, G ;
VOHRA, J ;
HUNT, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1983, 6 (05) :957-962
[9]   PERICARDIAL DECOMPRESSION [J].
LAJOS, TZ ;
BLACK, HE ;
COOPER, RG ;
WANKA, J .
ANNALS OF THORACIC SURGERY, 1975, 19 (01) :47-53
[10]   COMPARISON OF EFFECTIVENESS AND SAFETY OF OPERATIONS ON THE PERICARDIUM [J].
PALATIANOS, GM ;
THURER, RJ ;
KAISER, GA .
CHEST, 1985, 88 (01) :30-33