Diagnostic Performance of Integrated Positron Emission Tomography/Computed Tomography for Mediastinal Lymph Node Staging in Non-small Cell Lung Cancer A Bivariate Systematic Review and Meta-Analysis

被引:103
作者
Lv, Yan-Ling [2 ]
Yuan, Dong-Mei [1 ]
Wang, Ke [3 ]
Miao, Xiao-Hui [1 ]
Qian, Qian [4 ]
Wei, Shu-Zhen [5 ]
Zhu, Xi-Xu [6 ]
Song, Yong [1 ]
机构
[1] Nanjing Univ, Sch Med, Dept Resp Med, Jinling Hosp, Nanjing 210002, Peoples R China
[2] So Med Univ Guangzhou, Jinling Hosp, Dept Resp Med, Sch Med, Nanjing, Peoples R China
[3] Guangxi Med Univ, Affiliated Hosp 1, Inst Resp Dis, Nanning, Peoples R China
[4] Nanjing Chest Hosp, Dept Resp Med 1, Nanjing, Peoples R China
[5] Tengzhou Cent Peoples Hosp, Dept Resp Dis, Tengzhou, Peoples R China
[6] Nanjing Univ, Sch Med, Jinling Hosp, Dept Radiotherapy Ctr, Nanjing 210002, Peoples R China
关键词
Integrated positron emission tomography/Computed tomography; Mediastinal lymph node staging; Non-small cell lung cancer; Systematic review; Meta-analysis; STANDARDIZED UPTAKE VALUE; COMPUTED-TOMOGRAPHY; NEEDLE-ASPIRATION; PUBLICATION BIAS; F-18-FDG PET/CT; LESS ACCURATE; FDG-PET/CT; CT; FLUORODEOXYGLUCOSE; METASTASES;
D O I
10.1097/JTO.0b013e31821d4384
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Accurate clinical staging of mediastinal lymph nodes (MLNs) of patients with non-small cell lung cancer (NSCLC) is important in determining therapeutic options and prognoses. Integrated positron emission tomography and computed tomography (PET/CT) scanning is becoming widely used for MLN staging in patients with NSCLC. We performed a bivariate meta-analysis to determine the pooled sensitivity (SEN) and specificity (SPE) of this imaging modality. Methods: The PubMed/MEDLINE, Embase, and SpringerLink databases were searched for articles related to PET/CT for MLN staging in patients with NSCLC. SEN and SPE were calculated for every study. Hierarchical summary receiver operating characteristic curves were used to summarize overall test performance and assess study quality. Potential between-study heterogeneity was explored by subgroup analyses. Results: Fourteen of 330 initially identified reports were included in the meta-analysis. When we did not consider the unit of analysis, the pooled weighted SEN and SPE were 0.73 (95% confidence interval [CI]: 0.65-0.79) and 0.92 (95% CI: 0.88-0.94), respectively. In the patient-based data analysis, the pooled weighted SEN was 0.76 (95% CI: 0.65-0.84) and the pooled weighted SPE was 0.88 (95% CI: 0.82-0.92). In the MLN-based data analysis, the pooled SEN was 0.68 (95% CI: 0.56-0.78) and the pooled SPE was 0.95 (95% CI: 0.91-0.97). Conclusions: Integrated PET/CT is a relatively accurate noninvasive imaging technique, with excellent specificity for MLN staging in patients with NSCLC. Nevertheless, current evidence suggests that we should not depend on the results of PET/CT completely for MLN staging in patients with NSCLC.
引用
收藏
页码:1350 / 1358
页数:9
相关论文
共 50 条
[1]   Lymph node staging by means of positron emission tomography is less accurate in non-small cell lung cancer patients with enlarged lymph nodes: Analysis of 1145 lymph nodes [J].
Al-Sarraf, Nael ;
Gately, Kathy ;
Lucey, Julie ;
Wilson, Lorraine ;
McGovern, Eillish ;
Young, Vincent .
LUNG CANCER, 2008, 60 (01) :62-68
[2]   Pattern and predictors of occult mediastinal lymph node involvement in non-small cell lung cancer patients with negative mediastinal uptake on positron emission tomography [J].
Al-Sarraf, Nael ;
Aziz, Rashid ;
Gately, Kathy ;
Lucey, Julie ;
Wilson, Lorraine ;
McGovern, Eillish ;
Young, Vincent .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2008, 33 (01) :104-109
[3]  
Al-Sarraf Nael, 2007, Interact Cardiovasc Thorac Surg, V6, P350, DOI 10.1510/icvts.2006.150664
[4]  
[Anonymous], 2007, Midas: a program for meta-analytical integration of diagnostic accuracy studies in Stata
[5]   PUBLICATION BIAS - A PROBLEM IN INTERPRETING MEDICAL DATA [J].
BEGG, CB ;
BERLIN, JA .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES A-STATISTICS IN SOCIETY, 1988, 151 :419-463
[6]   Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography [J].
Bille, Andrea ;
Pelosi, Ettore ;
Skanjeti, Andrea ;
Arena, Vincenzo ;
Errico, Luca ;
Borasio, Piero ;
Mancini, Maurizio ;
Ardissone, Francesco .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 36 (03) :440-445
[7]   Meta-analysis of positron emission tomographic and computed tomographic imaging in detecting mediastinal lymph node metastases in nonsmall cell lung cancer [J].
Birim, Ö ;
Kappetein, AP ;
Stijnen, T ;
Bogers, AJJC .
ANNALS OF THORACIC SURGERY, 2005, 79 (01) :375-382
[8]   The clinical stage of non-small cell lung cancer as assessed by means of fluorodeoxyglucose-positron emission tomographic/computed tomographic scanning is less accurate in cigarette smokers [J].
Bryant, Ayesha S. ;
Cerfolio, Robert James .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (06) :1363-1368
[9]   Maximum standard uptake value of mediastinal lymph nodes on integrated FDG-PET-CT predicts pathology in patients with non-small cell lung cancer [J].
Bryant, Ayesha S. ;
Cerfolio, Robert J. ;
Klemm, Katrin M. ;
Ojha, Buddhiwardhan .
ANNALS OF THORACIC SURGERY, 2006, 82 (02) :417-423
[10]   The accuracy of integrated PET-CT compared with dedicated PET alone for the staging of patients with nonsmall cell lung cancer [J].
Cerfolio, RJ ;
Ojha, B ;
Bryant, AS ;
Raghuveer, V ;
Mountz, JM ;
Bartolucci, AA .
ANNALS OF THORACIC SURGERY, 2004, 78 (03) :1017-1023