Use of contactless conductivity detection for non-invasive characterisation of monolithic stationary-phase coatings for application in capillary ion chromatography

被引:36
作者
Gillespie, Eoin
Connolly, Damian
Macka, Miroslav
Nesterenko, Pavel N.
Paull, Brett [1 ]
机构
[1] Dublin City Univ, Natl Ctr Sensor Res, Sch Chem Sci, Dublin 9, Ireland
[2] Dublin City Univ, Ctr Bioanalyt Sci, Dublin 9, Ireland
[3] Univ Tasmania, Australian Ctr Res Separat Sci, Hobart, Tas 7001, Australia
关键词
D O I
10.1039/b711350a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A capacitively-coupled contactless conductivity detector ((CD)-D-4) has been utilised as an on-capillary detector within a capillary ion chromatograph, incorporating a reversed-phase monolithic silica capillary column semi-permanently modified with a suitable ionic surfactant. The monolithic capillary column ( 150 6 0.1 mm i. d.) was modified using sodium dioctyl sulfosuccinate ( DOSS), an anionic surfactant, for the separation of small inorganic and organic cations. With the use of the on-capillary conductivity detector, the longitudinal homogeneity and temporal stability of the coating were investigated. The approach allowed a detailed non-invasive observation of the nature of the ion-exchange coating over time, and an example of an application of the technique to produce a longitudinal stationary-phase charge gradient is shown. An investigation of the basis of the measured on-capillary conductivity was carried out with a counter ion study, clearly showing the on-capillary detection technique could also distinguish between chemical forms of the immobilised ion exchanger. The above method was used to produce a stable and homogeneously-modified monolithic ion-exchange capillary column, for application to the separation of inorganic alkaline earth cations and amino acids.
引用
收藏
页码:1238 / 1245
页数:8
相关论文
共 30 条
[1]   RADIAL DISPERSION FROM COMMERCIAL HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY COLUMNS INVESTIGATED WITH MICROVOLTAMMETRIC ELECTRODES [J].
BAUR, JE ;
KRISTENSEN, EW ;
WIGHTMAN, RM .
ANALYTICAL CHEMISTRY, 1988, 60 (21) :2334-2338
[2]   Visualization of viscous fingering in chromatographic columns [J].
Broyles, BS ;
Shalliker', RA ;
Cherrak, DE ;
Guiochon, G .
JOURNAL OF CHROMATOGRAPHY A, 1998, 822 (02) :173-187
[3]   Visualising the onset of viscous fingering in chromatography columns [J].
Catchpoole, Heather J. ;
Shalliker, R. Andrew ;
Dennis, Gary R. ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) :137-145
[4]   COLUMN EFFICIENCY AND RADIAL HOMOGENEITY IN LIQUID-CHROMATOGRAPHY [J].
FARKAS, T ;
CHAMBERS, JQ ;
GUIOCHON, G .
JOURNAL OF CHROMATOGRAPHY A, 1994, 679 (02) :231-245
[5]   Evaluation of capillary ion exchange stationary phase coating distribution and stability using radial capillary column contactless conductivity detection [J].
Gillespie, Eoin ;
Macka, Miroslav ;
Connolly, Damien ;
Paull, Brett .
ANALYST, 2006, 131 (08) :886-888
[6]   Simultaneous monitoring of inorganic cations, amines and amino acids in human sweat by capillary electrophoresis [J].
Hirokawa, Takeshi ;
Okamoto, Hikaru ;
Gosyo, Yoshinori ;
Tsuda, Takao ;
Timerbaev, Andrei R. .
ANALYTICA CHIMICA ACTA, 2007, 581 (01) :83-88
[7]   Capillary ion chromatography [J].
Kuban, P ;
Dasgupta, PK .
JOURNAL OF SEPARATION SCIENCE, 2004, 27 (17-18) :1441-1457
[8]   Application of gradient programs for the determination of underivatized amino acids and small peptides in reversed-phase high-performance liquid chromatography with contactless conductivity detection [J].
Kuban, Pavel ;
Hauser, Peter C. .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1128 (1-2) :97-104
[9]  
NIE F, 2007, LAB CHIP
[10]   Robust monolithic silica-based on-chip electro-osmotic micro-pump [J].
Nie, Fu-Qiang ;
Macka, Mirek ;
Barron, Leon ;
Connolly, Damian ;
Kent, Nigel ;
Paull, Brett .
ANALYST, 2007, 132 (05) :417-424