REPLACEMENT OF R404A AT HIGH CONDENSATION TEMPERATURE USING R454C AND R455A

被引:0
作者
Ramiro Haro-Ortuno, Jorge [1 ,2 ]
Mota-Babiloni, Adrian [1 ]
Navarro-Esbri, Joaquin [1 ]
Moles, Francisco [1 ]
Barragan-Cervera, Angel [1 ]
机构
[1] Univ Jaume 1, ISTENER Res Grp, E-12520 Castellon De La Plana, Spain
[2] Univ Politecn Valencia, Res Inst Ind Radiophys & Environm Safety ISIRYM, E-46022 Valencia, Spain
来源
1ST IIR INTERNATIONAL CONFERENCE ON THE APPLICATION OF HFO REFRIGERANTS | 2018年
关键词
Commercial refrigeration; COP; drop-in substitution; energy efficiency; HFC/HFO mixtures; low GWP; GWP REFRIGERANTS; ALTERNATIVES; PERFORMANCE;
D O I
10.18462/iir.hfo.2018.1152
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
R404A must be replaced for all commercial refrigeration applications following the instructions of the European F-gas Regulation. The recently developed mixtures R454C and R455A offer Global Warming Potential below 150, solutions with an ASHRAE 34 flammability classification of A2L. This paper presents and compares the experimental results of a refrigeration system using R404A, R454C and R455A, at a condensation temperature of 47 degrees C and evaporation temperatures of -13 and -30 degrees C. The experimental results show that, when using the alternative refrigerants instead of R404A, the refrigerating effect is increased, but the compressor suction density is lower. While the volumetric cooling capacity of R455A is comparable, that of R454C is lower than R404A. The coefficient of performance with both alternatives is significantly higher, so there is an energetic and hence environmental benefit from their utilization. The discharge temperature is within the limits, but it can be a limitation in higher compression ratios. The drop-in replacement only required adjustments in the TXV screw and in the refrigerant charge.
引用
收藏
页码:331 / 338
页数:8
相关论文
共 14 条
[1]  
[Anonymous], 2014, Off. J. Eur. Union, VL150, P195
[2]  
[Anonymous], 2015, ACR J
[3]   Using ANNs to approach to the energy performance for a small refrigeration system working with R134a and two alternative lower GWP mixtures [J].
Belman-Flores, J. M. ;
Mota-Babiloni, Adrian ;
Ledesma, Sergio ;
Makhnatch, Pavel .
APPLIED THERMAL ENGINEERING, 2017, 127 :996-1004
[4]   Refrigerants used in the Portuguese food industry: Current status [J].
Cardoso, Bruno J. ;
Lamas, Francisco B. ;
Gaspar, Adelio R. ;
Ribeiro, Jose B. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 83 :60-74
[5]   Low-GWP refrigerants for medium and highpressure applications [J].
Domanski, Piotr A. ;
Brignoli, Riccardo ;
Brown, J. Steven ;
Kazakov, Andrei F. ;
McLinden, Mark O. .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 :198-209
[6]  
Embraco, 2016, LIGHT COMM REF
[7]  
Federation of Environmental Trade Associations, 2017, INTR A2L REFR THEIR
[8]  
Lemmon E.W., 2018, NATL I STANDARDS TEC
[9]   Retrofit of lower GWP alternative R449A into an existing R404A indirect supermarket refrigeration system [J].
Makhnatch, Pavel ;
Mota-Babiloni, Adrian ;
Rogstam, Jorgen ;
Khodabandeh, Rahmatollah .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 76 :184-192
[10]   Recent investigations in HFCs substitution with lower GWP synthetic alternatives: Focus on energetic performance and environmental impact [J].
Mota-Babiloni, Adrian ;
Makhnatch, Pavel ;
Khodabandeh, Rahmatollah .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2017, 82 :288-301