A Nanometer Resolution Wearable Wireless Medical Device for Non Invasive Intracranial Pressure Monitoring

被引:45
作者
Andrade, Rodrigo de A. P. [1 ]
Oshiro, Helder Eiki [1 ]
Miyazaki, Caio Kioshi [1 ]
Hayashi, Cintya Yukie [2 ]
de Morais, Marcos Antonio [1 ]
Brunelli, Rodrigo [1 ]
Carmo, Joao Paulo [3 ]
机构
[1] Braincare Desenvolvimento & Inovacao Tecnol SA, Engn Dept, BR-13562420 Sao Carlos, Brazil
[2] Braincare Desenvolvimento & Inovacao Tecnol SA, Res Dept, BR-13562420 Sao Carlos, Brazil
[3] Univ Sao Paulo, Elect & Comp Engn Dept, BR-13566590 Sao Carlos, Brazil
关键词
Non-invasive intracranial pressure; intracranial pressure; intracranial compliance; skull deformation; medical device; wireless sensor; wearable sensor; nanometer resolution; displacement sensor; NEAR-INFRARED SPECTROSCOPY; ACUTE LIVER-FAILURE; CEREBROSPINAL-FLUID; BRAIN EDEMA; MANAGEMENT; WAVE; COMPLICATIONS; HYPERTENSION; ULTRASOUND; GUIDELINES;
D O I
10.1109/JSEN.2021.3090648
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The non-invasive intracranial pressure (NIICP) method based on a skull deformation has been proven to be a significant tool for an assessment of the intracranial pressure (ICP) and compliance. Herein, we present the development and characterization of a novel wireless sensor that uses this method as its working principle and was designed to be easy to use, to have a high resolution, and to achieve a good accessibility. Initially, a brief review of the physiology fundamentals of the ICP and the historic evolution of the NIICP method are mentioned. The sensor architecture and the rationale for the chosen components are then presented, aiming to ensure nanometer displacement measurements, the conversion of analog resolution to digital at a high speed, the fewest amount of distortion, wireless communication, and signal calibration. The NIICP signal has a typical amplitude of 5 mu m, and thus a resolution of at least 1% of this amplitude is required for an NIICP waveform analysis. We also demonstrate a 40-nm resolution of the sensor using a nanometric displacement test system that can also respond dynamically for NIICP signals from 50 to 180 bpm without any significant distortion (maximum deviation of P2/P1 ratio of 2.6%). The future applications for this device are broad and can enhance a clinical assessment of the intracranial dynamics.
引用
收藏
页码:22270 / 22284
页数:15
相关论文
共 89 条
[1]   NON-INVASIVE TRANSCRANIAL DOPPLER ULTRASOUND RECORDING OF FLOW VELOCITY IN BASAL CEREBRAL-ARTERIES [J].
AASLID, R ;
MARKWALDER, TM ;
NORNES, H .
JOURNAL OF NEUROSURGERY, 1982, 57 (06) :769-774
[2]   Absence of Disproportionately Enlarged Subarachnoid Space Hydrocephalus, a Sharp Callosal Angle, or Other Morphologic MRI Markers Should Not Be Used to Exclude Patients with Idiopathic Normal Pressure Hydrocephalus from Shunt Surgery [J].
Agerskov, S. ;
Wallin, M. ;
Hellstrom, P. ;
Ziegelitz, D. ;
Wikkelso, C. ;
Tullberg, M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2019, 40 (01) :74-79
[3]  
Alexander D, 2012, NASA EVIDENCE REPORT
[4]  
Andrade R, 2013, THESIS U SAO PAULO S
[5]  
[Anonymous], 2018, ADV TRAUM LIF SUPP A
[6]  
[Anonymous], NS281988R2015 ANSIAA
[7]  
[Anonymous], 2016, BP221994R2016 ANSIAA
[8]   Characterization of Shape Differences Among ICP Pulses Predicts Outcome of External Ventricular Drainage Weaning Trial [J].
Arroyo-Palacios, Jorge ;
Rudz, Maryna ;
Fidler, Richard ;
Smith, Wade ;
Ko, Nerissa ;
Park, Soojin ;
Bai, Yong ;
Hu, Xiao .
NEUROCRITICAL CARE, 2016, 25 (03) :424-433
[9]  
Basser PJ, 2000, MAGNET RESON MED, V44, P625, DOI 10.1002/1522-2594(200010)44:4<625::AID-MRM17>3.0.CO
[10]  
2-O