Micro- and macro-flow systems to study Escherichia coli adhesion to biomedical materials

被引:31
作者
Moreira, J. M. R. [1 ]
Ponmozhi, J. [2 ]
Campos, J. B. L. M. [2 ]
Miranda, J. M. [2 ]
Mergulhao, F. J. [1 ]
机构
[1] Univ Porto, Fac Engn, LEPABE Dept Chem Engn, P-4200465 Oporto, Portugal
[2] Univ Porto, Fac Engn, CEFT Dept Chem Engn, P-4200465 Oporto, Portugal
关键词
Adhesion; Escherichia coli; Microchannel; Parallel plate flow chamber; Biomedical materials; SURFACE FREE-ENERGY; BACTERIAL ADHESION; BIOFILM FORMATION; CONTACT ANGLES; SHEAR-STRESS; MICROFLUIDICS; MECHANISMS; COMPONENTS; ADHERENCE;
D O I
10.1016/j.ces.2014.12.054
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Micro- and macro-flow systems have been used as in vitro platforms to study bacterial adhesion under physiological conditions. The decision of which platform to use has been dictated by the dimensions of the in vivo systems that they are supposed to mimic and by the available resources in each laboratory. In this work, a microchannel and a parallel plate flow chamber were operated in order to observe the adhesion of Escherichia coli to different materials that are commonly used to construct biomedical devices for the urinary and reproductive systems. The surface properties of cellulose acetate, glass, poly-L-lactide, and polydimethylsiloxane were thermodynamically characterized by contact angle measurement and the flow along the platforms was simulated by computational fluid dynamics. The results presented in this study demonstrate that different adhesion rates were obtained on different materials but similar values were obtained in the micro- and macro-platforms for each material under the same shear stress (0.022 Pa). This suggests that despite the scale factor (80 x) both platforms may be equally used to mimic the same biomedical biofilms for a specified shear stress. Thus, depending on the expertise and equipment availability in different labs, micro-flow systems can be used taking advantage of lower hold-up volumes or macro-Row systems can be selected in order to obtain a higher biofilm mass which can be used for further biochemical analysis. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:440 / 445
页数:6
相关论文
共 51 条
  • [1] RECAPITULATING THE VASCULAR MICROENVIRONMENT IN MICROFLUIDIC PLATFORMS
    Abaci, Hasan E.
    Drazer, German
    Gerecht, Sharon
    [J]. NANO LIFE, 2013, 3 (01)
  • [2] Modification of polysiloxane polymers for biomedical applications: a review
    Abbasi, F
    Mirzadeh, H
    Katbab, AA
    [J]. POLYMER INTERNATIONAL, 2001, 50 (12) : 1279 - 1287
  • [3] An YH, 1998, J BIOMED MATER RES, V43, P338, DOI 10.1002/(SICI)1097-4636(199823)43:3<338::AID-JBM16>3.0.CO
  • [4] 2-B
  • [5] A flow chamber assay for quantitative evaluation of bacterial surface colonization used to investigate the influence of temperature and surface hydrophilicity on the biofilm forming capacity of uropathogenic Escherichia coli
    Andersen, Thomas Emil
    Kingshott, Peter
    Palarasah, Yaseelan
    Benter, Maike
    Alei, Mojagan
    Kolmos, Hans Jorn
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2010, 81 (02) : 135 - 140
  • [6] [Anonymous], URINARY CATHETER
  • [7] [Anonymous], MANUFACTURING METHOD
  • [8] [Anonymous], BIOFILMS BIOENGINEER
  • [9] [Anonymous], NUMERICAL SIMULATION
  • [10] The Bacterial Fimbrial Tip Acts as a Mechanical Force Sensor
    Aprikian, Pavel
    Interlandi, Gianluca
    Kidd, Brian A.
    Le Trong, Isolde
    Tchesnokova, Veronika
    Yakovenko, Olga
    Whitfield, Matt J.
    Bullitt, Esther
    Stenkamp, Ronald E.
    Thomas, Wendy E.
    Sokurenko, Evgeni V.
    [J]. PLOS BIOLOGY, 2011, 9 (05):