Smart Stylet: The Development and Use of a Bedside External Ventricular Drain Image-Guidance System

被引:11
作者
Patil, Vaibhav [1 ]
Gupta, Rajiv [3 ]
Estepar, Raul San Jose [1 ]
Lacson, Ronilda [1 ]
Cheung, Arnold [3 ]
Wong, Judith M. [2 ]
Popp, A. John [2 ]
Golby, Alexandra [1 ,2 ]
Ogilvy, Christopher [4 ]
Vosburgh, Kirby G. [1 ]
机构
[1] Brigham & Womens Hosp, Dept Radiol, Boston, MA 02115 USA
[2] Brigham & Womens Hosp, Dept Neurosurg, Boston, MA 02115 USA
[3] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
[4] Beth Israel Deaconess Med Ctr, Dept Neurosurg, Boston, MA 02215 USA
关键词
Ventriculostomy; Image-guided surgery; Electromagnetic concepts; Neuronavigation; FRAMELESS STEREOTACTIC SYSTEMS; CATHETER PLACEMENT; PEDIATRIC-PATIENTS; RISK-FACTORS; ACCURACY; NAVIGATION; HYDROCEPHALUS; TRACKING; MONITOR;
D O I
10.1159/000368906
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Background: Placement accuracy of ventriculostomy catheters is reported in a wide and variable range. Development of an efficient image-guidance system may improve physician performance and patient safety. Objective: We evaluate the prototype of Smart Stylet, a new electromagnetic image-guidance system for use during bedside ventriculostomy. Methods: Accuracy of the Smart Stylet system was assessed. System operators were evaluated for their ability to successfully target the ipsilateral frontal horn in a phantom model. Results: Target registration error across 15 intracranial targets ranged from 1.3 to 4.6 mm (mean 3.1 mm). Using Smart Stylet guidance, a test operator successfully passed a ventriculostomy catheter to a shifted ipsilateral frontal horn 20/20 (100%) times from the frontal approach in a skull phantom. Without Smart Stylet guidance, the operator was successful 4/10 (40%) times from the right frontal approach and 6/10 (60%) times from the left frontal approach. In a separate experiment, resident operators were successful 2/4 (50%) times when targeting the shifted ipsilateral frontal horn with Smart Stylet guidance and 0/4 (0%) times without image guidance using a skull phantom. Conclusions: Smart Stylet may improve the ability to successfully target the ventricles during frontal ventriculostomy. (C) 2015 S. Karger AG, Basel
引用
收藏
页码:50 / 58
页数:9
相关论文
共 26 条
[1]   Ventriculostomy-associated infections: Incidence and risk factors [J].
Arabi, Y ;
Memish, ZA ;
Balkhy, HH ;
Francis, C ;
Ferayan, A ;
Al Shimemeri, A ;
Almuneef, MA .
AMERICAN JOURNAL OF INFECTION CONTROL, 2005, 33 (03) :137-143
[2]   LEAST-SQUARES FITTING OF 2 3-D POINT SETS [J].
ARUN, KS ;
HUANG, TS ;
BLOSTEIN, SD .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1987, 9 (05) :699-700
[3]   Comparison of frameless stereotactic systems: Accuracy, precision, and applications [J].
Benardete, EA ;
Leonard, MA ;
Weiner, HL .
NEUROSURGERY, 2001, 49 (06) :1409-1415
[4]   A METHOD FOR REGISTRATION OF 3-D SHAPES [J].
BESL, PJ ;
MCKAY, ND .
IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 1992, 14 (02) :239-256
[5]   CONTINUOUS-PRESSURE CONTROLLED, EXTERNAL VENTRICULAR DRAINAGE FOR TREATMENT OF ACUTE HYDROCEPHALUS - EVALUATION OF RISK-FACTORS [J].
BOGDAHN, U ;
LAU, W ;
HASSEL, W ;
GUNREBEN, G ;
MERTENS, HG ;
BRAWANSKI, A ;
ROSNER, MJ ;
REKATE, HL .
NEUROSURGERY, 1992, 31 (05) :898-904
[6]   Electromagnetic tracking for image-guided abdominal procedures: Overall system and technical issues [J].
Cleary, Kevin ;
Zhang, Hui ;
Glossop, Neil ;
Levy, Elliot ;
Wood, Bradford ;
Banovac, Filip .
2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, :6748-6753
[7]   Placement of External Ventricular Drains and Intracranial Pressure Monitors by Neurointensivists [J].
Ehtisham, As'ad ;
Taylor, Scott ;
Bayless, Linda ;
Klein, Michael W. ;
Janzen, Jeff M. .
NEUROCRITICAL CARE, 2009, 10 (02) :241-247
[8]  
Greenberg M, 2010, HDB NEUROSURGERY, P208
[9]   Application of electromagnetic technology to neuronavigation: a revolution in image-guided neurosurgery Technical note [J].
Hayhurst, Caroline ;
Byrne, Patricia ;
Eldridge, Paul R. ;
Mallucci, Conor L. .
JOURNAL OF NEUROSURGERY, 2009, 111 (06) :1179-1184
[10]   Accuracy of the freehand pass technique for ventriculostomy catheter placement: retrospective assessment using computed tomography scans [J].
Huyette, David R. ;
Turnbow, Benjamin J. ;
Kaufman, Christian ;
Vaslow, Dale F. ;
Whiting, Benjamin B. ;
Oh, Michael Y. .
JOURNAL OF NEUROSURGERY, 2008, 108 (01) :88-91