Motion correction for native myocardial T1 mapping using self-supervised deep learning registration with contrast separation

被引:12
作者
Li, Yuze [1 ]
Wu, Chunyan [1 ]
Qi, Haikun [2 ]
Si, Dongyue [1 ]
Ding, Haiyan [1 ]
Chen, Huijun [1 ]
机构
[1] Tsinghua Univ, Ctr Biomed Imaging Res CBIR, Sch Med, Beijing, Peoples R China
[2] ShanghaiTech Univ, Sch Biomed Engn, Shanghai, Peoples R China
基金
中国国家自然科学基金;
关键词
motion correction; myocardial T-1 mapping; self-supervised deep learning; INVERSION-RECOVERY MOLLI; IMAGE REGISTRATION; FRAMEWORK; MODEL;
D O I
10.1002/nbm.4775
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In myocardial T-1 mapping, undesirable motion poses significant challenges because uncorrected motion can affect T-1 estimation accuracy and cause incorrect diagnosis. In this study, we propose and evaluate a motion correction method for myocardial T-1 mapping using self-supervised deep learning based registration with contrast separation (SDRAP). A sparse coding based method was first proposed to separate the contrast component from T-1-weighted (T1w) images. Then, a self-supervised deep neural network with cross-correlation (SDRAP-CC) or mutual information as the registration similarity measurement was developed to register contrast separated images, after which signal fitting was performed on the motion corrected T1w images to generate motion corrected T-1 maps. The registration network was trained and tested in 80 healthy volunteers with images acquired using the modified Look-Locker inversion recovery (MOLLI) sequence. The proposed SDRAP was compared with the free form deformation (FFD) registration method regarding (1) Dice similarity coefficient (DSC) and mean boundary error (MBE) of myocardium contours, (2) T-1 value and standard deviation (SD) of T-1 fitting, (3) subjective evaluation score for overall image quality and motion artifact level, and (4) computation time. Results showed that SDRAP-CC achieved the highest DSC of 85.0 +/- 3.9% and the lowest MBE of 0.92 +/- 0.25 mm among the methods compared. Additionally, SDRAP-CC performed the best by resulting in lower SD value (28.1 +/- 17.6 ms) and higher subjective image quality scores (3.30 +/- 0.79 for overall quality and 3.53 +/- 0.68 for motion artifact) evaluated by a cardiologist. The proposed SDRAP took only 0.52 s to register one slice of MOLLI images, achieving about sevenfold acceleration over FFD (3.7 s/slice).
引用
收藏
页数:12
相关论文
共 39 条
[1]   VoxelMorph: A Learning Framework for Deformable Medical Image Registration [J].
Balakrishnan, Guha ;
Zhao, Amy ;
Sabuncu, Mert R. ;
Guttag, John ;
Dalca, Adrian, V .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (08) :1788-1800
[2]   Fast myocardial T1 mapping using cardiac motion correction [J].
Becker, Kirsten M. ;
Blaszczyk, Edyta ;
Funk, Stephanie ;
Nuesslein, Andre ;
Schulz-Menger, Jeanette ;
Schaeffter, Tobias ;
Kolbitsch, Christoph .
MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (02) :438-451
[3]   Disentangle, Align and Fuse for Multimodal and Semi-Supervised Image Segmentation [J].
Chartsias, Agisilaos ;
Papanastasiou, Giorgos ;
Wang, Chengjia ;
Semple, Scott ;
Newby, David E. ;
Dharmakumar, Rohan ;
Tsaftaris, Sotirios A. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2021, 40 (03) :781-792
[4]   Magnetic resonance multitasking for motion-resolved quantitative cardiovascular imaging [J].
Christodoulou, Anthony G. ;
Shaw, Jaime L. ;
Nguyen, Christopher ;
Yang, Qi ;
Xie, Yibin ;
Wang, Nan ;
Li, Debiao .
NATURE BIOMEDICAL ENGINEERING, 2018, 2 (04) :215-226
[5]   Nonrigid active shape model-based registration framework for motion correction of cardiac T1 mapping [J].
El-Rewaidy, Hossam ;
Nezafat, Maryam ;
Jang, Jihye ;
Nakamori, Shiro ;
Fahmy, Ahmed S. ;
Nezafat, Reza .
MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) :780-791
[6]   A deep learning pipeline for automatic analysis of multi-scan cardiovascular magnetic resonance [J].
Fadil, Hakim ;
Totman, John J. ;
Hausenloy, Derek J. ;
Ho, Hee-Hwa ;
Joseph, Prabath ;
Low, Adrian Fatt-Hoe ;
Richards, A. Mark ;
Chan, Mark Y. ;
Marchesseau, Stephanie .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2021, 23 (01)
[7]   Cine and late gadolinium enhancement MRI registration and automated myocardial infarct heterogeneity quantification [J].
Guo, Fumin ;
Krahn, Philippa R. P. ;
Escartin, Terenz ;
Roifman, Idan ;
Wright, Graham .
MAGNETIC RESONANCE IN MEDICINE, 2021, 85 (05) :2842-2855
[8]   Cardiac T1 Mapping and Extracellular Volume (ECV) in clinical practice: a comprehensive review [J].
Haaf, Philip ;
Garg, Pankaj ;
Messroghli, Daniel R. ;
Broadbent, David A. ;
Greenwood, John P. ;
Plein, Sven .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2016, 18
[9]   Respiratory motion correction in dynamic MRI using robust data decomposition registration - Application to DCE-MRI [J].
Hamy, Valentin ;
Dikaios, Nikolaos ;
Punwani, Shonit ;
Melbourne, Andrew ;
Latifoltojar, Arash ;
Makanyanga, Jesica ;
Chouhan, Manil ;
Helbren, Emma ;
Menys, Alex ;
Taylor, Stuart ;
Atkinson, David .
MEDICAL IMAGE ANALYSIS, 2014, 18 (02) :301-313
[10]   Evaluation of Diffuse Myocardial Fibrosis in Heart Failure With Cardiac Magnetic Resonance Contrast-Enhanced T1 Mapping [J].
Iles, Leah ;
Pfluger, Heinz ;
Phrommintikul, Arintaya ;
Cherayath, Joshi ;
Aksit, Pelin ;
Gupta, Sandeep N. ;
Kaye, David M. ;
Taylor, Andrew J. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (19) :1574-1580